Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Basic information about the CE6885-48YS8CQ-T
Item | Details |
---|---|
Description | 02355KUC (CE6885-48YS8CQ-T switch (48*25GE SFP28, 8*100GE QSFP28, 2*AC Power Modules, 5*Fans, Port-side Exhaust)) |
Part Number | 02355KUC |
Model | CE6885-48YS8CQ-T |
First supported version | V300R023C00 |
Item | Specification |
---|---|
Dimensions with packaging (H x W x D) [mm (in.)] | 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the maximum distance from the protruding port on the front panel to the module handle on the rear panel): 43.6 mm x 442.0 mm x 446.5 mm (1.72 in. x 17.40 in. x 17.58 in.) |
Weight without packaging [kg (lb)] | 6.36 kg (14.02 lb) (excluding optical modules, power modules, and fan modules) |
Weight without packaging (full configuration) [kg (lb)] | 8.55 kg (18.85 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported) |
Weight with packaging [kg (lb)] | 10.63 kg (23.43 lb) |
Weight with packaging (full configuration) [kg (lb)] | 12.82 kg (28.26 lb) |
Installation Type | Cabinet installation |
CPU | 4-core, 1.4 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
SSD Flash | 4GB SSD |
USB |
It can be used for log backup and USB-based deployment. This function is reserved. |
Power supply mode |
|
Console port | RJ45 |
Downlink Service interface | 48 x 25GE SFP28/48 x 50GE SFP56 |
Uplink Service interface | 8 x 100GE QSFP28/8 x 200GE QSFP56 |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] |
48 x 25G + 8 x 100G: 147 W (100% traffic load, copper cables on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 166 W (100% traffic load, short-distance optical modules on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 48 x 50G + 8 x 200G: 177 W (100% traffic load, copper cables on 24 x 50G ports, short-distance optical modules on 4 x 200G ports, normal temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] |
48 x 25G + 8 x 100G: 502 BTU/hr (100% traffic load, copper cables on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 566 BTU/hr (100% traffic load, short-distance optical modules on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 48 x 50G + 8 x 200G: 604 BTU/hr (100% traffic load, copper cables on 24 x 50G ports, short-distance optical modules on 4 x 200G ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 136 W |
Static heat dissipation [BTU/hour] | 464 BTU/hr |
Maximum power consumption [W] |
48 x 25G + 8 x 100G: 200 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 326 W (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) 48 x 50G + 8 x 200G: 227 W (100% traffic load, copper cables on 48 x 50G ports, short-distance optical modules on 8 x 200G ports, normal temperature, dual AC power modules) 328 W (100% traffic load, copper cables on 48 x 50G ports, long-distance optical modules on 8 x 200G ports, high temperature, dual AC power modules) |
Maximum heat dissipation |
48 x 25G + 8 x 100G: 682 BTU/hr (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 1112 BTU/hr (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) 48 x 50G + 8 x 200G: 775 BTU/hr (100% traffic load, copper cables on 48 x 50G ports, short-distance optical modules on 8 x 200G ports, normal temperature, dual AC power modules) 1119 BTU/hr (100% traffic load, copper cables on 48 x 50G ports, long-distance optical modules on 8 x 200G ports, high temperature, dual AC power modules) |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
|
Rated output power [W] |
|
Certification |
· Compliance with safety standards · Compliance with EMC standards · Compliance with environment and environmental protection standards |
Power supply surge protection [kV] |
AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 5 |
Redundant fans | The device supports 4+1 backup of fan modules that work in hot standby mode. If a single fan module fails, the device can work properly in a short period of time. To guarantee long-term operation of the device, you are advised to replace the failed fan module immediately |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake/port-side air exhaust, depending on the selected fan module and power module. |
Availability | 0.9999947936 |
MTBF [year] | 43.85 year |
MTTR [hour] | 2 hour |
Noise at normal temperature (27°C, sound pressure) [dB(A)] |
Front-to-back airflow: Average: 52.8 dB(A); max: 58.7 dB(A) Back-to-front airflow: Average: 51.3 dB(A); max: 59.0 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] |
Front-to-back airflow: Average: 69.5 dB(A); max: 76.0 dB(A) Back-to-front airflow: Average: 70.2 dB(A); max: 75.6 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] |
0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
RTU License Supported |
Yes. By default, 48 x 25GE ports can only work at the rate of 25 Gbit/s, and eight 100GE ports can only work at the rate of 100 Gbit/s. You can use the RTU license (BOM number: 88036EUQ) to increase the rate of 25GE ports to 50 Gbit/s and the rate of 100GE ports to 200 Gbit/s. |
Packing:
1. Original Carton Package.
2. As your requirement.
Delivery:
1. 3-7 Working days after received the payment.
2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )
1.Quality: All products from HW and new.
2.Reply on time: Your inquiry related to our products or price will be replied within 24 hours.
3.OEM&ODM: We can help you to design and put your good idea into products.
4.Warranty: 1-years warranty.
5.Technology support: On-site technical support, Telemaintenance, Free call and E-mail technology supports.
6.Training service support: Provide free training service on installation and debugging technology supports.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu.
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, ZTE, H3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours.
The core team comes from manufacturers such as Hua wei and H3C, with technical staff certified by HCIE, HCNP, and other engineers. Most of them have more than 5 years of work experience and have a 7 * 24 hour fast response ability. They can provide users with planning, debugging, and emergency upgrade services.
The company has its own data transmission room and equipment maintenance factory, with a product database of over 300GB, focusing on data communication, transmission, wireless, server, storage, and security products. With no less than 1 year of after-sales tracking, it can provide users with remote and local installation services to ensure the stable
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.