Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Part Number | 02354LHV | |
Model | CE8850E-32CQ-EI | |
Description | CE8850E-32CQ-EI Switch (32*100GE QSFP28,1*10GE SFP+,without fan and power module) |
Hardware specifications
Technical Specifications | |
Other part numbers | 02354LHX-001 (CE8850E-32CQ-EI Switch (32*100GE QSFP28,1*10GE SFP+,2*AC power module,4*fan module,port-side intake)) 02354LJA-001 (CE8850E-32CQ-EI Switch (32*100GE QSFP28,1*10GE SFP+,2*AC power module,4*fan module,port-side exhaust)) 02355MSH (CE8850E-32CQ-EI Switch (32*100GE QSFP28, 1*10GE SFP+,without fan and power module)) 02355MSJ (CE8850E-32CQ-EI Switch (32*100GE QSFP28, 1*10GE SFP+, 2*AC power module,4*fan module, port-side intake)) 02355MSR (CE8850E-32CQ-EI Switch (32*100GE QSFP28, 1* 10GE SFP+, 2*AC power module,4*fan module, port-side exhaust)) |
Installation Type | Cabinet Installation |
Depth [mm] | 420.0 mm |
Chassis height [U] | 1 |
Wide [mm] | 442.0 mm |
Height [mm] | 43.6 mm |
Weight with packaging [kg(lb)] | 9.3 kg (20.50 lb) |
Weight without packaging [kg(lb)] | 6.0 kg (13.23 lb) (excluding optical modules, power modules, and fan modules) |
Maximum power consumption [W] | 339 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 450 W (100% traffic load, long-distance optical modules on all ports, 40°C or 104°F, dual AC power modules) |
Typical power consumption [W] | 203 W (100% traffic load, copper cables on half of ports, normal temperature, dual AC power modules) 244 W (100% traffic load, short-distance optical modules on half of ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 165 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation [BTU/hour] | 1157 BTU/hour (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 1535 BTU/hour (100% traffic load, long-distance optical modules on all ports, 40°C or 104°F, dual AC power modules) |
Typical heat dissipation [BTU/hour] | 693 BTU/hour (100% traffic load, copper cables on half of ports, normal temperature, dual AC power modules) 833 BTU/hour (100% traffic load, short-distance optical modules on half of ports, normal temperature, dual AC power modules) |
Static heat dissipation [BTU/hour] | 563 BTU/hour |
Power supply mode | AC,DC,HVDC |
Rated input voltage [V] | - 600 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 1000 W DC power module: -48 V DC to -60 V DC - 1200 W high-voltage DC power module: 240 V DC to 380 V DC |
Input voltage range [V] | - 600 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC - 1000 W DC power module: -38.4 V DC to -72 V DC - 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A] | - 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) - 1000 W DC power module: 30 A (-48 V DC to -60 V DC) - 1200 W high-voltage DC power module: 8 A |
Rated output power [W] | - 600 W AC&240 V DC power module: 600 W - 1000 W DC power module: 1000 W - 1200 W high-voltage DC power module: 1200 W |
Memory | DRAM: 4 GB |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
USB | Supported |
Console port | RJ45 |
Downlink Service interface | 32 x 100GE QSFP28 ports and 1 x 10GE SFP+ port, regardless of the direction (uplink or downlink) Note: 1. 100GE ports except port 23 can be split into 4 x 25GE or 4 x 10GE ports. After the split, they cannot be used as GE ports. 2. Splitting 100GE port 23, using 10GE port 1, and configuring IOAM are mutually exclusive. 100GE port 23 supports only static split, and the device needs to be restarted for the split to take effect. 3. The 10GE SFP+ port can function as a GE SFP optical/electrical port. 4. Supported optical modules: (1) In the case of port-side air intake, 100GE ports support 100G-AOC/SR4/DR/LR4/4WDM optical modules. (2) In the case of port-side air exhaust, 100GE ports support 100G-AOC/SR4/DR/LR4 optical modules. |
Service port supporting the stack function | 100GE optical port |
RTC | Supported |
Switching capacity [bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | 1+1 backup |
Number of power modules | 2 |
Power supply surge protection | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Airflow direction | Front-to-back or back-to-front airflow, depending on the selected fan modules and power modules |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
MTBF [year] | 35.88 years |
MTTR [hour] | 1.89 hours |
Noise at high temperature (40°C, sound pressure) | Front-to-back airflow: 67.6 dB(A) on average (maximum: 73.4 dB(A)) Back-to-front airflow: 68 dB(A) on average (maximum: 75.4 dB(A)) |
Noise at normal temperature (27°C, sound pressure) | Front-to-back airflow: 49.8 dB(A) on average (maximum: 53.6 dB(A)) Back-to-front airflow: 47.8 dB(A) on average (maximum: 51.2 dB(A)) |
Availability | 0.999993932 |
Item | CloudEngine 8850E-32CQ-EI |
Device virtualization | Intelligent stack (iStack) |
M-LAG | |
Data center interconnect (DCI) | VXLAN mapping, enabling Layer 2 interconnection between DCs |
Network virtualization | VXLAN routing and VXLAN bridging |
BGP-EVPN | |
TRILL (supported only by the CloudEngine 8850-64CQ-EI) | |
QinQ access VXLAN | |
SDN | iMaster NCE-Fabric |
Network convergence | Fibre Channel over Ethernet (FCoE) |
Data Center Bridging Exchange Protocol (DCBX), Priority-based Flow Control (PFC), and expanded trunking system (ETS) | |
Remote direct memory access (RDMA) and RoCE (RoCEv1 and RoCEv2) | |
Programmability | OPS programming |
Ansible-based automatic configuration and open-source module release | |
Traffic analysis | NetStream |
sFlow | |
VLAN | Access, trunk, and hybrid ports |
Default VLAN | |
QinQ | |
MUX VLAN | |
GARP VLAN Registration Protocol (GVRP) | |
MAC address entry | Automatic MAC address learning and aging |
Static, dynamic, and blackhole MAC address entries | |
Source MAC address filtering | |
MAC address learning limiting by port and VLAN ID | |
IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP |
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
IPv6 | IPv6 VXLAN over IPv4 |
VXLAN over IPv6 (supported only by the CE8850E-32CQ-EI) | |
IPv6 neighbor discovery (ND) | |
Path MTU Discovery (PMTU) | |
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | |
Multicast | Multicast routing protocols, such as the Internet Group Multicast Protocol (IGMP), Protocol Independent |
Multicast-Sparse Mode (PIM-SM), Protocol Independent Multicast-Dense Mode (PIM-DM), Multicast Source Discovery Protocol (MSDP), and Multicast BGP (MBGP) | |
IGMP snooping | |
IGMP proxy | |
Fast leaving of multicast member interfaces | |
Multicast traffic suppression | |
Multicast VLAN | |
Multicast VXLAN | |
MPLS | Basic MPLS |
Reliability | Link Aggregation Control Protocol (LACP) |
STP, RSTP, VBST, and MSTP | |
BPDU protection, root protection, and loop prevention | |
Smart Link and multi-instance | |
Device Link Detection Protocol (DLDP) | |
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms | |
G.8032 Ethernet Ring Protection Switching (ERPS) | |
VRRP, VRRP load sharing, and BFD for VRRP | |
BFD for BGP, IS-IS, OSPF, and static routing | |
BFD for VXLAN | |
QoS | Traffic classification based on Layer 2 protocol headers, Layer 3 protocol headers, and Layer 4 protocol priorities |
ACL, CAR, re-marking, and scheduling | |
Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR | |
Congestion avoidance mechanisms such as WRED and tail drop | |
Traffic shaping | |
Intelligent O&M | Network-wide path detection |
1588v2 (supported only by the CloudEngine 8850-64CQ-EI) | |
Telemetry | |
INT (IOAM) and enhanced ERSPAN | |
Intelligent traffic analysis | |
RoCE traffic visualization: RoCE traffic KPI analysis | |
Statistics collection on the buffer microburst status | |
VXLAN OAM: VXLAN ping and VXLAN tracert | |
Intelligent lossless network | PFC deadlock prevention |
AI ECN: The switch intelligently adjusts the ECN thresholds of lossless queues based on the live-network traffic model. | |
Fast CNP: The switch directly sends CNP packets to server NICs at the source end to shorten the CNP feedback path. | |
DLB | |
ECN overlay | |
INC (supported only by the CE8850-64CQ-EI) | |
Configuration and maintenance | Terminal login through the console port, Telnet, and SSH |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
802.3az Energy Efficient Ethernet (EEE) |
BOM Number
|
License Query
|
Abbreviation
|
Description
|
---|---|---|---|
88036RYF |
N1 UPG-A-P upgrade package of the CE8800 |
N1-CE88UPG-A-P |
Controlled features: The iMaster NCE-Fabric intent standard package, FabricInsight network flow analysis, IFIT, iMaster NCE-Fabric digital map standard package, iMaster NCE-Fabric per virtual network system - digital map scenario package, and FabricInsight IFIT service assurance functions |
88036KVQ |
N1 UPG-F-A upgrade package of the CE8800 |
N1-CE88UPG-F-A |
Controlled features: FabricInsight network health, iMaster NCE-Fabric multi-cloud multi-DC scenario package, FabricInsight multi-cloud multi-DC analysis scenario package, enhanced DAD in a stack, and iMaster NCE-Fabric OPP scenario package functions |
88061EFF |
Annual fee of the N1 UPG-F-A upgrade package of the CE8800 |
N1-CE88UGFA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037RGT |
CE8800 IFIT function |
CE88-LIC-IFIT |
Controlled features: IFIT function |
88033DNJ |
FCF for all ports of the CE8800 |
CE88-LIC-FCFAL |
Controlled feature: FCF function |
88035TFC |
N1 FabricInsight network intelligent basic analysis of the CE8800 |
N1-CE-F-LIC-FIF |
Controlled features: FabricInsight network intelligent basic analysis and Telemetry functions |
88035DWP |
N1 foundation function package of the CE8800 |
N1-CE88LIC-CFFD |
Controlled features: CE8800 management by iMaster NCE-Fabric, the FabricInsight network intelligent basic analysis, basic software , Telemetry, discarded packet capture, IOAM, 1588v2 (PTP), VXLAN functions |
88060QDN |
Annual fee of the enhanced function package A of the CE8800 |
N1-CE88ADA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88035TFH |
N1 FabricInsight network intelligent value-added analysis of the CE8800 (per 1000 VMs) |
N1-CE-LIC-FIA-1KVM |
Controlled features: FabricInsight network intelligent value-added analysis (per 1000 VMs) function |
88061LJL |
Annual fee of the N1 premium function package of the CE8800 |
N1-CE88CFPM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037XYJ |
CE8800 AI Fabric RDMA application acceleration function package |
N1-CE88LIC-AFRD |
Controlled feature: Buffer optimization for lossless queues, differentiated flow scheduling, dynamic ECN, AI ECN, and fast CNP functions |
88035DWR |
N1 advanced function package of the CE8800 |
N1-CE88LIC-CFAD |
Controlled features: CE8800 management by iMaster NCE-Fabric, the FabricInsight network intelligent basic analysis, FabricInsight network health, basic software , Telemetry, discarded packet capture, IOAM, 1588v2 (PTP), VXLAN, iMaster NCE-Fabric multi-cloud multi-DC scenario package, FabricInsight multi-cloud multi-DC analysis scenario package, enhanced DAD in a stack, and iMaster NCE-Fabric OPP scenario package functions |
88038CPJ |
Digital map function package |
N1-CE-F-LIC-DM |
Controlled features: The iMaster NCE-Fabric digital map standard package and iMaster NCE-Fabric per virtual network system - digital map scenario package function |
88062SNB |
Annual fee of the digital map function package |
N1-CEFDM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88033DNH |
FCF for 16 ports of the CE8800 |
CE88-LIC-FCF16 |
Controlled feature: FCF function |
88060QCU |
Annual fee of the N1 management function package on the CE8800 |
N1-CE88CFMM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060PKK |
Annual fee of the N1 FabricInsight network intelligent basic analysis on the CE8800 |
N1-CEFFIF-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88034RKK |
Telemetry function of the CE8800 |
CE88-LIC-TLM |
Controlled feature: Telemetry function |
88034RKK |
IOAM function of the CE8800 |
CE88-LIC-TLM |
Controlled feature: Telemetry, Discarded packet capture function, IOAM function |
88061RUW |
Annual fee of the Value-added package for multi-cloud and multi-DC scenarios |
N1-CEFMDCA -SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
Active Device | |
CE8850E-32CQ-EI | CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,without fan and power module) |
CE8850E-32CQ-EI-B | CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,2*AC power module,4*fan module,portside intake) |
CE8850E-32CQ-EI-F | CE8850E-32CQ-EI Switch(32*100GE QSFP28, 1*10GE SFP+, 2*AC power module,4*fan module, port-side exhaust) |
Power module | ||
Model | Description | Applicable product |
PHD1K2S12-DB | 1200W HVDC Power Module (Back to Front,Power panel side exhaust) | CE8850E-32CQ-EI |
PDC1000S12-DB | 1000W DC Power Module (Power panel side exhaust) | CE8850E-32CQ-EI |
PDC1000S12-DF | 1000W DC Power Module (Power panel side intake) | CE8850E-32CQ-EI |
PAC600S12-EB | 600W AC&240V DC Power Module (Back to Front,Power panel side exhaust) | CE8850E-32CQ-EI |
PAC600S12-EF | 600W AC&240V DC Power Module (Front to Back,Power panel side intake) | CE8850E-32CQ-EI |
Fan module | ||
Model | Description | Applicable product |
FAN-031A-F | Fan box(F,FAN panel side intake) | CE8850E-32CQ-EI |
FAN-031A-B | Fan box(B,FAN panel side exhaust) | CE8850E-32CQ-EI |
Software | ||
CE88-LIC-BUN01 | CE8800 Function License Bundle 1 | |
CE88-LIC-TLM | CE8800 Telemetry Function | |
CE88-LIC-PTP | CE8800 PTP Function (supported only by the CE8850-64CQ-EI) | |
CE88-LIC-AIF | CloudEngine 8800 AI Fabric Function | |
N1-CE88LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 8800 | |
N1-CE88CFFD-SnS1Y | N1-CE8800 CloudFabric Foundation Software Package-Subscription and Support-Year | |
N1-CE88LIC-CFAD | N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year | |
Active Device | ||
N1-CE88CFAD-SnS1Y | N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year | |
N1-CE88LIC-CFPM | N1- CloudEngine 8800 CloudFabric Premium Software Package | |
N1-CE88CFPM-SnS1Y | N1- CloudEngine 8800 CloudFabric Premium Software Package-Subscription and Support-Year | |
N1-CE88LIC-AIF | N1-CloudEngine 8800 AI Fabric Function | |
N1-CE88AIF-SnS1Y | N1-CE8800 AI Fabric Function-Subscription and Support-Year | |
N1-CE88LIC-HPC | N1-CloudEngine 8800 AI Fabric HPC Scenario Value-added Package | |
N1-CE88HPC-SnS1Y | N1-CloudEngine 8800 AI Fabric HPC Storage Scenario Value-added Package-Subscription and Support-Year |
|
N1-CE-F-LIC-MDCA | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed |
N1-CEFMDCA -SnS1Y | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed DeviceSubscription and Support-Year |
N1-CE88UPG-F-A | N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced |
N1-CE88UGFA-SnS1Y | N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced- Subscription and Support-Year |
N1-CE88UPG-A-P | N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium |
N1-CE88UGAP-SnS1Y | N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium-Subscription and Support-Year |
Packing:1.Original Carton Package. 2. As your requirement. |
|
Delivery:1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software
After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu. |
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, Z TE, H 3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours. |
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.