CE9860-4C-EI-A (02355FEA)
Item | Details |
---|---|
Description | CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules) |
Part Number | 02355FEA |
Model | CE9860-4C-EI-A |
First supported version | V200R022C10 |
Other part numbers |
02355FEB (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, port-side intake)) 02355FUM (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card, port-side intake)) 02355MRU (CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules)) 02355MRV (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, port-side intake)) 02355MRW (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card, port-side intake)) |
Short Name | CE9860EI |
Slot Type | Slot ID | Slot Direction | Remarks |
---|---|---|---|
Power supply slots | - | Horizontal insertion |
NOTE:
If 1200 W AC&240 V DC power modules (PAC1K2S12) are installed on the switch and 110 V AC power input is provided to the power modules:
|
Fan slots | - | Horizontal insertion |
|
Port | Connector Type | Description | Available Components |
---|---|---|---|
Console port | RJ45 | Connects to the console for onsite configuration. |
Console cable |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. |
Category-5 or higher category Ethernet cable |
USB port | USB | The USB port can have a USB flash drive connected to back up and upload logs and system software, and supports USB-based deployment. |
USB flash drive |
Item | Specification |
---|---|
Dimensions with packaging (H x W x D) [mm (in.)] | 370 mm x 635 mm x 1025 mm (14.57 in. x 25 in. x 40.35 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] |
|
Weight without packaging [kg (lb)] | 26.9 kg (59.30 lb) (excluding fan modules, power modules, and cards) |
Weight without packaging (full configuration) [kg (lb)] |
43.2 kg (95.24 lb) (with four power modules, four fan modules, and four cards) 33.04 kg (72.84 lb) (with four power modules and four fan modules) |
Weight with packaging [kg (lb)] | 51.9 kg (114.42 lb) (excluding fan modules, power modules, and cards) |
Weight with packaging (full configuration) [kg (lb)] |
68.2 kg (150.36 lb) (with four power modules, four fan modules, and four cards) 58.04 kg (127.96 lb) (with four power modules and four fan modules) |
Installation Type | Cabinet installation |
CPU | 16-core, 2 GHz |
Memory | DRAM: 16 GB |
NOR Flash | 64 MB x 2 |
SSD Flash | 8 GB |
USB | Supported |
Power supply mode |
|
Console port | RJ45 |
Downlink Service interface |
The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards: CE98-D32CQ-A: 32 x 100GE QSFP28 (Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. A 100GE QSFP28 port cannot be split into 4x25GE and 4x10GE ports. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on M-LAG peer-link ports.) CE98-D8DQ: 8 x 400GE QSFP-DD (In V200R021C00, such ports can only work at 400 Gbit/s, cannot be used as 200GE, 100GE, or 40GE ports, and cannot be split. Auto-negotiation of 400GE copper cables is not supported and such cables can be used only for peer-link. In V200R021C10, such a 400GE port can be dynamically split into two 200GE ports. Currently, only 2*200GE 5 m AOCs and 2.5 m copper cables are supported. By default, negotiation is disabled and cannot be enabled for copper cables. If an unsupported module is inserted into such a port, the system displays a message indicating a medium mismatch.) |
Service port supporting the stack function | Not supported |
RTC | Supported |
Typical power consumption [W] |
Configured with four CE98-D32CQ-A cards: 1291 W (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 953 W (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Typical heat dissipation [BTU/hour] |
Configured with four CE98-D32CQ-A cards: 4205 BTU/hr (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 3252 BTU/hr (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Static power consumption [W] |
Configured with four CE98-D32CQ-A cards: 900 W Configured with four CE98-D8DQ cards: 621 W |
Static heat dissipation [BTU/hour] |
Configured with four CE98-D32CQ-A cards: 3071 BTU/hour Configured with four CE98-D8DQ cards: 2119 BTU/hour |
Maximum power consumption [W] |
Configured with four CE98-D32CQ-A cards: 2253 W (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) Configured with four CE98-D8DQ cards: 1677 W (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) |
Maximum heat dissipation |
Configured with four CE98-D32CQ-A cards: 7688 BTU/hour (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) Configured with four CE98-D8DQ cards: 5722 BTU/hour (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) |
Number of power modules | 4 |
Redundant power supply | 2+2 backup |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
|
Rated output power [W] |
|
Certification |
|
Power supply surge protection [kV] |
AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Redundant fans | Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short period of time. However, you are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side. |
Availability | 0.999997861 |
MTBF [year] | 42.79 year |
MTTR [hour] | 1.73 hour |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Back-to-front airflow: < 66 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Back-to-front airflow: < 81 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] |
0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
1.Original Carton Package.
2. As your requirement.
1. 3-7 Working days after received the payment.
2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )
1.Quality: All products from HUAWEI and new.
2.Reply on time: Your inquiry related to our products or price will be replied within 24 hours.
3.OEM&ODM: We can help you to design and put your good idea into products.
4.Warranty: 1-years warranty.
5.Technology support: On-site technical support, Telemaintenance, Free call and E-mail technology supports.
6.Training service support: Provide free training service on installation and debugging technology supports.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu.
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as Huawei, ZTE, H3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours.
The core team comes from manufacturers such as Huawei and H3C, with technical staff certified by HCIE, HCNP, and other engineers. Most of them have more than 5 years of work experience and have a 7 * 24 hour fast response ability. They can provide users with planning, debugging, and emergency upgrade services.
The company has its own data transmission room and equipment maintenance factory, with a product database of over 300GB, focusing on data communication, transmission, wireless, server, storage, and security products. With no less than 1 year of after-sales tracking, it can provide users with remote and local installation services to ensure the stable operation of their equipment.
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.
Suppliers with verified business licenses