Part Number | 02355LFN |
Model | AR8700-8 |
Description | AR8700-8 assembly chassis |
First supported version | V600R022C10 |




Technical Specifications | |
Installation type | Rack |
Height[mm] | 88.1 mm |
Depth[mm] | 482.8 mm |
Wide[mm] | 442.0 mm |
Chassis height[U] | 2 |
Weight with packaging[kg] | 18.7 (41.22) |
Weight without packaging[kg] | 15 (33.07) |
Number of service board slots | 8 |
XSIC slots (default/maximum) | 0/2 |
WSIC slots (default/maximum) | 0/4 |
SIC slots (default/maximum) | 8/8 |
MIC slots (default/maximum) | 0/0 |
Per-slot bandwidth | Slot 1: The maximum bandwidth is 1 Gbit/s. Slot 2: The maximum bandwidth is 10 Gbit/s. Slot 3: The maximum bandwidth is 1 Gbit/s. Slot 4: The maximum bandwidth is 10 Gbit/s. Slot 5: The maximum bandwidth is 1 Gbit/s. Slot 6: The maximum bandwidth is 10 Gbit/s. Slot 7: The maximum bandwidth is 1 Gbit/s. Slot 8: The maximum bandwidth is 10 Gbit/s. |
Redundant power supply | - Double AC power modules (1+1 backup) - Double DC power modules (1+1 backup) |
Redundant MPUs | 1:1 |
RPS input | Not supported |
PoE | Not supported |
IP rating | IP20 |
MTBF[year] | 33.83 |
MTTR[h] | 2 |
Availability | 0.9999932515 |
Maximum power consumption[W] | 288(SPU+2*MPU+FAN) |
Typical power consumption[W] | 221(SPU+2*MPU+FAN) |
Power supply mode | AC/HVDC pluggable, DC pluggable |
Number of power modules | 2 |
Input voltage range[V] | - DC input: –38.4 V DC to –72 V DC - AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz - High-voltage DC input: 190 V DC to 290 V DC |
Rated input voltage[V] | - DC input: –48 V DC/–60 V DC - AC input: 110 V AC/220 V AC, 50 Hz/60 Hz - High-voltage DC input: 240 V DC Note: When the input voltage of an AC power module is 110 V, the AC power module cannot be used together with other power modules. If the AC power module is used together with other power modules, overcurrent protection may be triggered for the AC power module. |
Maximum input current[A] | 600 W AC: 8 A (100-130 V AC input) /8 A (200-240 V AC input) 600 W HVDC: 4 A 1000 W AC: 12 A (100-130 V AC input) /8 A (200-240 V AC input) 1000 W HVDC: 8 A 1000 W DC: 30 A |
Maximum output power | 600 W AC: 300 W (100-130 V AC input) /600 W (200-240 V AC input) 600 W HVDC: 600 W 1000 W AC: 900 W (100-130 V AC input) /1000 W (200-240 V AC input) 1000 W HVDC: 1000 W 1000 W DC: 1000 W |
Types of fans | Pluggable |
Number of fan modules | 1 |
Heat dissipation mode | Air cooling |
Airflow | Left-to-rear airflow + front-to-rear airflow |
Noise at normal temperature (acoustic power) | 57.6 |
Storage temperature[°C] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature[°C] | 0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Long-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude[m] | < 5000 m (16404.2 ft.) |
Overtemperature alarm | Supported |
Environmental standards compliance | RoHS REACH WEEE |
Safety regulation certification | IEC 60950-1 IEC 62368-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950-1 GB 4943.1 |
EMC certification | EN 55032 EN 55035 CISPR 32 CISPR 35 IEC/EN 61000-3-2 EN 61000-3-3 ETSI EN 300 386 ETSI EN 301 489-1 ETSI EN 301 489-3 ETSI EN 301 489-17 ETSI EN 301 489-52 FCC CFR Part 15, Subpart B ANSI C63.4 ICES-003 Issue 7 EN 50121-1 EN 50121-4 GB 9254 |