CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch

Product Details
Customization: Available
Communication Mode: Full Duplex
Type: Ethernet Switch
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (16)
  • CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
Find Similar Products

Basic Info.

Model NO.
CE9860-4C-EI-A (02355FEA)
Ports
0
Compliance
Meets Global Regulatory Certifications and Industr
Cooling System
4 Hot-Swappable Fan Modules with Port-Side Exhaust
Form Factor
1u Rack-Mountable
Forwarding Performance
High-Performance Forwarding with Low Latency
Layer 2 and Layer 3 Switching
Supports Both Ethernet Switching and IP Routing
Management Interface
Ethernet Management Port, Console Port, USB Port
Model
CE9860-4c-Ei-a
Operating Humidity
5% to 95% Rh (Non-Condensing)
Part Number
02355fea
Power Supply
Redundant, Hot-Swappable AC Power Modules
Quality of Service (Qos)
Advanced Qos Features for Traffic Management
Switching Capacity
High Switching Capacity to Support Demanding Netwo
Security Features
Advanced Security Features Including Acls, Secure
Weight
Approximately 14 Kg (30.9 Lbs)
Transport Package
Mail Box
Specification
370 mm x 635 mm x 1025 mm
Trademark
HW
Origin
Hubei, China
Production Capacity
100pieces/Month

Product Description

Overview

Table 4-304 Basic information about the CE9860-4C-EI-A
Item Details
Description CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules)
Part Number 02355FEA
Model CE9860-4C-EI-A
First supported version V200R022C10
Other part numbers

02355FEB (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, port-side intake))

02355FUM (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card, port-side intake))

02355MRU (CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules))

02355MRV (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, port-side intake))

02355MRW (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card, port-side intake))

Short Name CE9860EI

Appearance

Figure 4-319 Appearance of the CE9860-4C-EI-A

CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch
CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network SwitchThe figures in this document are for reference only.


Components

Figure 4-320 Components of the CE9860-4C-EI-A
CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch

1

Ground screw

2

SN and MAC address label

3

Console port

4

ETH management port (RJ45)

5

USB 2.0 port

6

Fan slot 1

Applicable fan modules:
  • FAN-180C series fan modules

7

Fan slot 2

Applicable fan modules:
  • FAN-180C series fan modules

8

Fan slot 3

Applicable fan modules:
  • FAN-180C series fan modules

9

Fan slot 4

Applicable fan modules:
  • FAN-180C series fan modules

10

Power supply slot 1

Applicable power modules:

  • 1200 W AC&240 V DC power module
  • 1200 W DC Power Module

11

Power supply slot 2

Applicable power modules:

  • 1200 W AC&240 V DC power module
  • 1200 W DC Power Module

12

Power supply slot 3

Applicable power modules:

  • 1200 W AC&240 V DC power module
  • 1200 W DC Power Module

13

Power supply slot 4

Applicable power modules:

  • 1200 W AC&240 V DC power module
  • 1200 W DC Power Module

14

Card slot 1

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ
  • CE98-D32CQ-A

15

Card slot 2

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

16

Card slot 3

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

17

Card slot 4

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

18

-

Slot Layout

Table 4-305 Slots on the CE9860-4C-EI-A
Slot Type Slot ID Slot Direction Remarks
Power supply slots - Horizontal insertion
  • Each CloudEngine 9860-4C-EI-A switch has four power supply slots, in which pluggable power modules can be installed to provide power to the chassis. Install at least two power modules. Four power modules can provide higher reliability. If only two power modules are used, do not upgrade, downgrade, or replace them.
  • CloudEngine 9860-4C-EI-A switches support four power modules working in 2+2 backup mode.
NOTE:

If 1200 W AC&240 V DC power modules (PAC1K2S12) are installed on the switch and 110 V AC power input is provided to the power modules:

  • Use an external power source that provides 110 V input with double live wires. In this case, each power module provides 1200 W of rated output power and the power modules work in 2+2 backup mode.
  • If the external power source provides 110 V input with a single live wire, each power module provides 800 W of rated output power. In this case, the power modules cannot work in 2+2 backup mode.
Fan slots - Horizontal insertion
  • Each CloudEngine 9860-4C-EI-A switch has four fan slots, in which pluggable fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have four working fan modules to ensure normal operating.
  • All fan modules are hot swappable.

Indicators

Figure 4-321 Indicators on the CE9860-4C-EI-A
CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch

1. System status indicator

2. Stack master/slave indicator

3. ETH management port indicator

4. USB-based deployment indicator

5. ID indicator

Table 4-306 Indicators on the CE9860-4C-EI-A
Silkscreen Name Color Status Description
SYS System status indicator Green Steady off The system is not running.
Green Fast blinking The system is starting.
Green Slow blinking The system is running normally.
Red Steady on
  • An exception occurs during device startup.
  • The power module is abnormal.
  • The fan module is abnormal.
MST Stack master/slave indicator Green Steady on The CloudEngine 9860-4C-EI does not support the stack function. Therefore, this indicator is invalid.
L/A Management port indicator Green Steady off No link is established on the port.
Green Steady on A link is established on the port.
Yellow Blinking The port is sending or receiving data.
USB USB-based deployment indicator Green Steady off USB-based deployment is disabled (default state).
Green Steady on USB-based deployment has been completed.
Green Blinking The system is reading data from a USB flash drive.
Red Steady on USB-based deployment fails.
ID ID indicator Blue Steady off The ID indicator is disabled (default status).
Blue Steady on The ID indicator can be turned on or off remotely to help field engineers find the device to maintain.

Ports

Table 4-307 Ports on the CE9860-4C-EI-A
Port Connector Type Description Available Components
Console port RJ45 Connects to the console for onsite configuration.

Console cable

ETH management port RJ45 You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.

Category-5 or higher category Ethernet cable

USB port USB The USB port can have a USB flash drive connected to back up and upload logs and system software, and supports USB-based deployment.

USB flash drive

Heat Dissipation System

CloudEngine 9800 series switches use back-to-front airflow. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If a switch is installed with the port side facing the front and the power supply side facing the back, the switch needs to adopt fan modules and power modules with back-to-front airflow.

CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch

  • Back-to-front airflow: Power modules and fan modules with back-to-front airflow are identified by CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch or CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch. Air flows into the chassis from the port side and is exhausted from the power supply side, as shown in Figure 4-322 (using a CE5800 chassis as an example).
  • Power modules and fan modules using forced air cooling on a switch must have the same airflow direction. If a switch adopts power modules with back-to-front airflow, the switch must use fan modules with back-to-front airflow as well.
Figure 4-322 Back-to-front airflow for port-side intake
CE9860-4c-Ei-a (02355FEA) Cloudengine 9800 Series Network Switch

Technical Specifications

Table 4-308 Technical specifications of the CE9860-4C-EI-A
Item Specification
Dimensions with packaging (H x W x D) [mm (in.)] 370 mm x 635 mm x 1025 mm (14.57 in. x 25 in. x 40.35 in.)
Dimensions without packaging (H x W x D) [mm (in.)]
  • Basic dimensions (excluding the parts protruding from the body): 175 mm x 442 mm x 765 mm (6.89 in. x 17.4 in. x 30.12 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 175 mm x 442 mm x 817.5 mm (6.89 in. x 17.4 in. x 32.19 in.)
Weight without packaging [kg (lb)] 26.9 kg (59.30 lb) (excluding fan modules, power modules, and cards)
Weight without packaging (full configuration) [kg (lb)]

43.2 kg (95.24 lb) (with four power modules, four fan modules, and four cards)

33.04 kg (72.84 lb) (with four power modules and four fan modules)

Weight with packaging [kg (lb)] 51.9 kg (114.42 lb) (excluding fan modules, power modules, and cards)
Weight with packaging (full configuration) [kg (lb)]

68.2 kg (150.36 lb) (with four power modules, four fan modules, and four cards)

58.04 kg (127.96 lb) (with four power modules and four fan modules)

Installation Type Cabinet installation
CPU 16-core, 2 GHz
Memory DRAM: 16 GB
NOR Flash 64 MB x 2
SSD Flash 8 GB
USB Supported
Power supply mode
  • AC
  • DC
  • HVDC
Console port RJ45
Downlink Service interface

The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards:

CE98-D32CQ-A: 32 x 100GE QSFP28 (Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. A 100GE QSFP28 port cannot be split into 4x25GE and 4x10GE ports. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on M-LAG peer-link ports.)

CE98-D8DQ: 8 x 400GE QSFP-DD (In V200R021C00, such ports can only work at 400 Gbit/s, cannot be used as 200GE, 100GE, or 40GE ports, and cannot be split. Auto-negotiation of 400GE copper cables is not supported and such cables can be used only for peer-link. In V200R021C10, such a 400GE port can be dynamically split into two 200GE ports. Currently, only 2*200GE 5 m AOCs and 2.5 m copper cables are supported. By default, negotiation is disabled and cannot be enabled for copper cables. If an unsupported module is inserted into such a port, the system displays a message indicating a medium mismatch.)

Service port supporting the stack function Not supported
RTC Supported
Typical power consumption [W]

Configured with four CE98-D32CQ-A cards: 1291 W (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules)

Configured with four CE98-D8DQ cards: 953 W (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules)

Typical heat dissipation [BTU/hour]

Configured with four CE98-D32CQ-A cards: 4205 BTU/hr (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules)

Configured with four CE98-D8DQ cards: 3252 BTU/hr (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules)

Static power consumption [W]

Configured with four CE98-D32CQ-A cards: 900 W

Configured with four CE98-D8DQ cards: 621 W

Static heat dissipation [BTU/hour]

Configured with four CE98-D32CQ-A cards: 3071 BTU/hour

Configured with four CE98-D8DQ cards: 2119 BTU/hour

Maximum power consumption [W]

Configured with four CE98-D32CQ-A cards: 2253 W (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.)

Configured with four CE98-D8DQ cards: 1677 W (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.)

Maximum heat dissipation

Configured with four CE98-D32CQ-A cards: 7688 BTU/hour (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.)

Configured with four CE98-D8DQ cards: 5722 BTU/hour (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.)

Number of power modules 4
Redundant power supply 2+2 backup
Rated input voltage [V]
  • 1200 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC
  • 1200 W DC power module: -48 V DC: -48 V DC to -60 V DC; +48 V DC: +40 V DC to +57 V DC
Input voltage range [V]
  • 1200 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC
  • 1200 W DC power module: -48 V DC: -38.4 V DC to -72 V DC; +48 V DC: +38.4 V DC to +60 V DC
Maximum input current [A]
  • 1200 W AC&240 V DC power module: 10 A (100 V AC to 130 V AC); 8 A (200 V AC to 240 V AC); 8 A (240 V DC)
  • 1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC)
Rated output power [W]
  • 1200 W AC&240 V DC power module: 1200 W
  • 1200 W DC power module: 1200 W
Certification
  • Complies with safety standards.
  • Complies with EMC standards.
  • Complies with environmental protection standards.
Power supply surge protection [kV]

AC: 6 kV in common mode and 6 kV in differential mode

DC: 4 kV in common mode and 2 kV in differential mode

HVDC: 4 kV in common mode and 2 kV in differential mode

Types of fans Pluggable
Number of fans 4
Redundant fans Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short period of time. However, you are advised to replace the faulty fan module immediately.
Heat dissipation mode Air cooling
Airflow direction Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
Availability 0.999997861
MTBF [year] 42.79 year
MTTR [hour] 1.73 hour
Noise at normal temperature (27°C, sound pressure) [dB(A)] Back-to-front airflow: < 66 dB(A)
Noise at high temperature (40°C, sound pressure) [dB(A)] Back-to-front airflow: < 81 dB(A)
Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating temperature [°C (°F)]

0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)

NOTE:

When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Storage relative humidity [RH] 5% to 95% RH, non-condensing
Storage temperature [°C (°F)] -40ºC to +70ºC (-40°F to +158°F)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier