Customization: | Available |
---|---|
Communication Mode: | Full Duplex |
Type: | Ethernet Switch |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Details |
---|---|
Description | CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules) |
Part Number | 02355FEA |
Model | CE9860-4C-EI-A |
First supported version | V200R022C10 |
Other part numbers |
02355FEB (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, port-side intake)) 02355FUM (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card, port-side intake)) 02355MRU (CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules)) 02355MRV (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, port-side intake)) 02355MRW (CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card, port-side intake)) |
Short Name | CE9860EI |
1 |
Ground screw |
2 |
SN and MAC address label |
3 |
Console port |
4 |
ETH management port (RJ45) |
5 |
USB 2.0 port |
6 |
Fan slot 1
Applicable fan modules:
|
7 |
Fan slot 2
Applicable fan modules:
|
8 |
Fan slot 3
Applicable fan modules:
|
9 |
Fan slot 4
Applicable fan modules:
|
10 |
Power supply slot 1 Applicable power modules:
|
11 |
Power supply slot 2 Applicable power modules:
|
12 |
Power supply slot 3 Applicable power modules:
|
13 |
Power supply slot 4 Applicable power modules:
|
14 |
Card slot 1 Applicable cards:
|
15 |
Card slot 2 Applicable cards:
|
16 |
Card slot 3 Applicable cards:
|
17 |
Card slot 4 Applicable cards:
|
18 |
- |
Slot Type | Slot ID | Slot Direction | Remarks |
---|---|---|---|
Power supply slots | - | Horizontal insertion |
NOTE:
If 1200 W AC&240 V DC power modules (PAC1K2S12) are installed on the switch and 110 V AC power input is provided to the power modules:
|
Fan slots | - | Horizontal insertion |
|
1. System status indicator |
2. Stack master/slave indicator |
3. ETH management port indicator |
4. USB-based deployment indicator |
5. ID indicator |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
SYS | System status indicator | Green | Steady off | The system is not running. |
Green | Fast blinking | The system is starting. | ||
Green | Slow blinking | The system is running normally. | ||
Red | Steady on |
|
||
MST | Stack master/slave indicator | Green | Steady on | The CloudEngine 9860-4C-EI does not support the stack function. Therefore, this indicator is invalid. |
L/A | Management port indicator | Green | Steady off | No link is established on the port. |
Green | Steady on | A link is established on the port. | ||
Yellow | Blinking | The port is sending or receiving data. | ||
USB | USB-based deployment indicator | Green | Steady off | USB-based deployment is disabled (default state). |
Green | Steady on | USB-based deployment has been completed. | ||
Green | Blinking | The system is reading data from a USB flash drive. | ||
Red | Steady on | USB-based deployment fails. | ||
ID | ID indicator | Blue | Steady off | The ID indicator is disabled (default status). |
Blue | Steady on | The ID indicator can be turned on or off remotely to help field engineers find the device to maintain. |
Port | Connector Type | Description | Available Components |
---|---|---|---|
Console port | RJ45 | Connects to the console for onsite configuration. |
Console cable |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. |
Category-5 or higher category Ethernet cable |
USB port | USB | The USB port can have a USB flash drive connected to back up and upload logs and system software, and supports USB-based deployment. |
USB flash drive |
CloudEngine 9800 series switches use back-to-front airflow. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If a switch is installed with the port side facing the front and the power supply side facing the back, the switch needs to adopt fan modules and power modules with back-to-front airflow.
Item | Specification |
---|---|
Dimensions with packaging (H x W x D) [mm (in.)] | 370 mm x 635 mm x 1025 mm (14.57 in. x 25 in. x 40.35 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] |
|
Weight without packaging [kg (lb)] | 26.9 kg (59.30 lb) (excluding fan modules, power modules, and cards) |
Weight without packaging (full configuration) [kg (lb)] |
43.2 kg (95.24 lb) (with four power modules, four fan modules, and four cards) 33.04 kg (72.84 lb) (with four power modules and four fan modules) |
Weight with packaging [kg (lb)] | 51.9 kg (114.42 lb) (excluding fan modules, power modules, and cards) |
Weight with packaging (full configuration) [kg (lb)] |
68.2 kg (150.36 lb) (with four power modules, four fan modules, and four cards) 58.04 kg (127.96 lb) (with four power modules and four fan modules) |
Installation Type | Cabinet installation |
CPU | 16-core, 2 GHz |
Memory | DRAM: 16 GB |
NOR Flash | 64 MB x 2 |
SSD Flash | 8 GB |
USB | Supported |
Power supply mode |
|
Console port | RJ45 |
Downlink Service interface |
The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards: CE98-D32CQ-A: 32 x 100GE QSFP28 (Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. A 100GE QSFP28 port cannot be split into 4x25GE and 4x10GE ports. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on M-LAG peer-link ports.) CE98-D8DQ: 8 x 400GE QSFP-DD (In V200R021C00, such ports can only work at 400 Gbit/s, cannot be used as 200GE, 100GE, or 40GE ports, and cannot be split. Auto-negotiation of 400GE copper cables is not supported and such cables can be used only for peer-link. In V200R021C10, such a 400GE port can be dynamically split into two 200GE ports. Currently, only 2*200GE 5 m AOCs and 2.5 m copper cables are supported. By default, negotiation is disabled and cannot be enabled for copper cables. If an unsupported module is inserted into such a port, the system displays a message indicating a medium mismatch.) |
Service port supporting the stack function | Not supported |
RTC | Supported |
Typical power consumption [W] |
Configured with four CE98-D32CQ-A cards: 1291 W (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 953 W (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Typical heat dissipation [BTU/hour] |
Configured with four CE98-D32CQ-A cards: 4205 BTU/hr (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 3252 BTU/hr (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Static power consumption [W] |
Configured with four CE98-D32CQ-A cards: 900 W Configured with four CE98-D8DQ cards: 621 W |
Static heat dissipation [BTU/hour] |
Configured with four CE98-D32CQ-A cards: 3071 BTU/hour Configured with four CE98-D8DQ cards: 2119 BTU/hour |
Maximum power consumption [W] |
Configured with four CE98-D32CQ-A cards: 2253 W (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) Configured with four CE98-D8DQ cards: 1677 W (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) |
Maximum heat dissipation |
Configured with four CE98-D32CQ-A cards: 7688 BTU/hour (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) Configured with four CE98-D8DQ cards: 5722 BTU/hour (when the ambient temperature is 40°C (104 °F), the fan speed is 100% of the full speed.) |
Number of power modules | 4 |
Redundant power supply | 2+2 backup |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
|
Rated output power [W] |
|
Certification |
|
Power supply surge protection [kV] |
AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Redundant fans | Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short period of time. However, you are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side. |
Availability | 0.999997861 |
MTBF [year] | 42.79 year |
MTTR [hour] | 1.73 hour |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Back-to-front airflow: < 66 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Back-to-front airflow: < 81 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] |
0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |