CE9860-4c-Ei Cloudengine 9800 Series Network Switch

Product Details
Customization: Available
Application: Enterprise Level
Command System: Vrp (Versatile Routing Platform)
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (16)
  • CE9860-4c-Ei Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei Cloudengine 9800 Series Network Switch
  • CE9860-4c-Ei Cloudengine 9800 Series Network Switch
Find Similar Products
  • Overview
  • Product Description
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
9860-4C-EI
Cooling System
4 Hot-Swappable Fan Modules with Port-Side Exhaust
Dimensions (Hxwxd)
43.6 mm X 442 mm X 600 mm
Form Factor
1u Rack-Mountable
Forwarding Performance
High-Performance Forwarding with Low Latency
Management Interface
Ethernet Management Port, Console Port, USB Port
Model
CE9860-4c-Ei
Network Management
Supports Cli, Snmp, Telnet, Ssh, and Web-Based Man
Operating Humidity
5% to 95% Rh (Non-Condensing)
Power Supply
Redundant, Hot-Swappable AC Power Modules
Series
Cloudengine 9800
Weight
Approximately 14 Kg (30.9 Lbs) Without Modules
Transport Package
Mail Box Packing
Specification
1.72 in x 17.4 in x 23.6 in
Trademark
HW
Origin
Hubei, China
Production Capacity
100pieces/Per Month

Product Description

Product Description

02355FEA Network Switch CE9860-4C-EI 4 x 100GE QSFP28 Ports


Offering exceptional performance and high port density, the CloudEngine 9800 series switches are designed to meet the needs of modern data centers and high-demand enterprise networks. The CE9860-4C-EI features advanced hardware with 4 x 100GE QSFP28 ports, delivering high bandwidth and low latency for demanding applications. This switch supports high-speed data transfer and efficient network management, making it ideal for core and aggregation layers in large-scale data center environments. It is engineered to offer scalability and reliability, integrating seamlessly with other CloudEngine series switches to build flexible, high-performance, and secure network infrastructures.
 
Basic Information
Part Number CE9860-4C-EI Switch
Model CE9860-4C-EI
Description CE9860-4C-EI Switch

Version Mapping

Table 4-298 lists the mappings between the CE9860-4C-EI and software versions.

Table 4-298 Version mapping

Device Series

Sub-series

Device Model

Short Name

Supported Version

CE9800

CE9860

CE9860-4C-EI

CE9860EI

V200R020C00 and later versions

Appearance and Structure

CE9860-4c-Ei Cloudengine 9800 Series Network Switch

The figures in this document are for reference only.

Figure 4-316 CE9860-4C-EI
CE9860-4c-Ei Cloudengine 9800 Series Network Switch

1

Ground screw

2

SN and MAC address label

3

Console port

4

ETH management port (RJ45)

5

USB 2.0 port

6

Fan slot 1

Applicable fan modules:
  • FAN-180C series fan modules

7

Fan slot 2

Applicable fan modules:
  • FAN-180C series fan modules

8

Fan slot 3

Applicable fan modules:
  • FAN-180C series fan modules

9

Fan slot 4

Applicable fan modules:
  • FAN-180C series fan modules

10

Fan slot 5

Applicable fan modules:
  • FAN-180C series fan modules

11

Power supply slot 1

Applicable power modules:
  • 1200 W AC&240 V DC power module
  • 1200 W power module
  • 1200 W DC Power Module

12

Power supply slot 2

Applicable power modules:

  • 1200 W AC&240 V DC power module
  • 1200 W power module
  • 1200 W DC Power Module

13

Power supply slot 3

Applicable power modules:
  • 1200 W AC&240 V DC power module
  • 1200 W power module
  • 1200 W DC Power Module

14

Power supply slot 4

Applicable power modules:
  • 1200 W AC&240 V DC power module
  • 1200 W power module
  • 1200 W DC Power Module

15

Card slot 1

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

16

Card slot 2

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

17

Card slot 3

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

18

Card slot 4

Applicable cards:

  • CE98-D32CQ
  • CE98-D8DQ

19

Mounting brackets

CE9860-4c-Ei Cloudengine 9800 Series Network Switch

Cable management frames can be installed on the mounting brackets to route cables on the cards installed in the corresponding slots.

-

-

Slot Description

  • Power Supply Slots

    Each CloudEngine 9800 series switch has four power supply slots, in which pluggable power modules can be installed to provide power to the chassis. Install at least two power modules. Four power modules can provide higher reliability. If only two power modules are used, do not upgrade, downgrade, or replace them.

    CloudEngine 9800 series switches support four power modules working in 2+2 backup mode.
     

    If 1200 W AC&240 V DC power modules (PAC1K2S12) are installed on the switch and 110 V AC power input is provided to the power modules:

    1. Use an external power source that provides 110 V input with double live wires. In this case, each power module provides 1200 W of rated output power and the power modules work in 2+2 backup mode.
    2. If the external power source provides 110 V input with a single live wire, each power module provides 800 W of rated output power. In this case, the power modules cannot work in 2+2 backup mode.
  • Fan Slots

    Each CloudEngine 9800 series switch has five fan slots, in which pluggable fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have five working fan modules to ensure normal operating.

    All fan modules are hot swappable.

Heat Dissipation System

CloudEngine 9800 series switches use back-to-front airflow. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If a switch is installed with the port side facing the front and the power supply side facing the back, the switch needs to adopt fan modules and power modules with back-to-front airflow.

  • Back-to-front airflow: Power modules and fan modules with back-to-front airflow are identified by CE9860-4c-Ei Cloudengine 9800 Series Network Switch or CE9860-4c-Ei Cloudengine 9800 Series Network Switch. Air flows into the chassis from the port side and is exhausted from the power supply side, as shown in Figure 4-317 (using a CE5800 chassis as an example).
  • Power modules and fan modules using forced air cooling on a switch must have the same airflow direction. If a switch adopts power modules with back-to-front airflow, the switch must use fan modules with back-to-front airflow as well.
Figure 4-317 Back-to-front airflow for port-side intake
CE9860-4c-Ei Cloudengine 9800 Series Network Switch

Indicators

Figure 4-318 Indicators on the CE9860-4C-EI front panel
CE9860-4c-Ei Cloudengine 9800 Series Network Switch
Table 4-299 Indicator description

No.

Indicator

Name

Color

Status

Description

1

SYS

System status indicator

Green

Off

The system is not running.

Fast blinking

The system is starting.

Slow blinking

The system is running normally.

Red

Steady on

  • The system fails to start.
  • At least one power module does not work normally.
  • At least one fan module does not work normally.

2

MST

Stack master/slave indicator

-

Steady on

The CE9860-4C-EI does not support the stacking function. Therefore, this indicator is invalid.

3

L/A

ETH management port indicator

Green

Off

No link is established on the port.

Steady on

A link is established on the port.

Blinking

The port is sending or receiving data.

4

USB

USB-based deployment indicator

Green

Off

USB-based deployment is disabled (default state).

Steady on

USB-based deployment has been completed.

Blinking

The system is reading data from a USB flash drive.

Red

Steady on

USB-based deployment has failed.

5

ID

ID indicator

Blue

Off

The ID indicator is not used (default state).

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

Ports

Console Port

The console port is connected to a console for onsite configuration. The port must use a console cable. Table 4-300 describes the attributes of the console port.
Table 4-300 Attributes of the console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s to 115200 bit/s

Default value: 9600 bit/s

ETH Management Port (RJ45)

The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 4-301 describes the attributes of the ETH management port (RJ45).
Table 4-301 Attributes of the ETH management port (RJ45)

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3ab

Working mode

Supported rate: 10/100/1000 Mbit/s auto-sensing

Full-duplex

Maximum transmission distance

100 m

USB Port

A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.

Specifications

Table 4-302 lists technical specifications of the CE9860-4C-EI switch.

Table 4-302 Technical specifications

Item

Description

Physical specifications

  • Dimensions (H x W x D): 175.0 mm x 442.0 mm x 765.0 mm (6.9 in. x 17.4 in. x 30.1 in.)
  • Weight (with four power modules and five fan modules, calculated based on the heaviest model if multiple models are supported): 46.2 kg (101.85 lb)

Environment parameters

Temperature

  • Operating temperature: 0°C to 40°C (32°F to 104°F) at altitude of 0-1800 m (0-5906 ft.)
    NOTE:

    When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

  • Storage temperature: -40°C to +70°C (-40°F to +158°F)

Relative humidity

5% RH to 95% RH, noncondensing

Altitude

< 5000 m (16404 ft.)

Noise (sound pressure, 27°C)

Back-to-front airflow: < 66 dBA

Power specifications

Power source type

AC/High-voltage DC

AC power input

  • Rated input voltage range: 100 V AC to 240 V AC, 50/60 Hz
  • Maximum input voltage range: 90 V AC to 290 V AC, 45 Hz to 65 Hz

High-voltage DC power input

  • Rated voltage of 240 V high-voltage DC power input: 240 V DC
  • Maximum voltage range of 240 V high-voltage DC power input: 190 V DC to 290 V DC

Rated input current

  • 1200 W AC&240 V DC power module (PAC1K2S12 series): 10 A (100 V AC to 130 V AC)/8 A (200 V AC to 240 V AC)/8 A (240 V DC)

Chassis power consumption

 

Maximum power consumption

Configured with four CE98-D32CQ cards: 1627 W (70% of the full fan speed at an ambient temperature of 40°C)

Configured with four CE98-D8DQ cards: 1717 W (full fan speed at an ambient temperature of 40°C)

Typical power consumption

Fully configured with four CE98-D32CQ cards: 1231 W (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on another 64 ports, two power modules)

Configured with four CE98-D8DQ cards: 1289 W (50% throughput, short-distance QSFPDD optical modules on 32 ports, two power modules)

Static power consumption

Configured with four CE98-D32CQ cards: 377 W

Configured with four CE98-D8DQ cards: 548 W

Chassis heat dissipation

 

Maximum heat dissipation

Configured with four CE98-D32CQ cards: 5553 BTU/hour (70% of the full fan speed at an ambient temperature of 40°C)

Configured with four CE98-D8DQ cards: 5861 BTU/hour (full fan speed at an ambient temperature of 40°C)

Typical heat dissipation

Fully configured with four CE98-D32CQ cards: 4202 BTU/hr (50% throughput, 64-port short-distance QSFP28 optical module and 64-port long-distance QSFP28 optical module, double power modules)

Configured with four CE98-D8DQ cards: 4400 BTU/hr (50% throughput, short-distance QSFPDD optical modules on 32 ports, two power modules)

Static heat dissipation

Configured with four CE98-D32CQ cards: 1505 BTU/hour

Configured with four CE98-D8DQ cards: 1871 BTU/hour

Surge protection

PAC1K2S12-B series power module:

  • AC: 4 kV in common mode and 2.5 kV in differential mode
  • DC: 4 kV in common mode and 2 kV in differential mode

PAC1K2S12-CB series power module:

  • AC: 6 kV in common mode and 6 kV in differential mode
  • DC: 4 kV in common mode and 2 kV in differential mode

Heat dissipation

Heat dissipation mode

Air cooling

Airflow

Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.

Reliability and availability

Power module backup

2+2 backup

Fan module backup

Five fan modules, working in 4+1 backup mode when the temperature is below 35°C

Hot swap

Supported by all power modules and fan modules

Mean time between failures (MTBF)

21.91 years

Mean time to repair (MTTR)

3.43 hours

Availability

0.9999934738

Technical specifications

Processor

2.2 GHz, 8-thread, four-core

DRAM memory

16 GB

NOR Flash

Two 32 MB flash memories

SSD Flash

64 GB

Stack

Service port supporting the stacking function

Not supported

Certification

  • Safety standards compliance
  • EMC standards compliance
  • Environmental standards compliance

Ordering Information

Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact HW switch distributors or local HW representative office.

Table 4-303 provides the ordering information.

Table 4-303 Ordering information

Part Number

Part Model

Part Description

02352HQC

CE9860-4C-EI

CE9860-4C-EI mainframe (4*subcard slots, without fan and power modules)

02352HQD

CE9860-4C-EI-B

CE9860-4C-EI mainframe (4*subcard slots, 4*AC power modules, 5*fan modules, port-side intake)

CE9860-4c-Ei Cloudengine 9800 Series Network SwitchCE9860-4c-Ei Cloudengine 9800 Series Network SwitchCE9860-4c-Ei Cloudengine 9800 Series Network Switch
Packaging & Shipping

Packaging & Shipping

 1. Original Carton Package.

 2. As your requirement.

 

Delivery:

 1. 3-7 Working days after received the payment.

 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )



Our services

1.Quality: All products from HW and new.

2.Reply on time: Your inquiry related to our products or price will be replied within 24 hours.

3.OEM&ODM: We can help you to design and put your good idea into products.

4.Warranty: 1-years warranty.

5.Technology support: On-site technical support, Telemaintenance, Free call and E-mail technology supports.

6.Training service support: Provide free training service on installation and debugging technology supports.

 
Company Profile

Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu.

 

Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, ZT E, H3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours.

 

The core team comes from manufacturers such as Hua wei and H3C, with technical staff certified by HCIE, HCNP, and other engineers. Most of them have more than 5 years of work experience and have a 7 * 24 hour fast response ability. They can provide users with planning, debugging, and emergency upgrade services.

 

The company has its own data transmission room and equipment maintenance factory, with a product database of over 300GB, focusing on data communication, transmission, wireless, server, storage, and security products. With no less than 1 year of after-sales tracking, it can provide users with remote and local installation services to ensure the stable

 
FAQ
 

1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.

2. Can I buy samples placing orders?
Yes. Please feel free to contact us.

3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.

4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.

5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.

6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier