Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Basic Information | |
Part Number | 02352HQC |
Model | CE9860-4C-EI |
Description | CE9860-4C-EI mainframe (4*subcard slots, without fan and power modules) |
Technical Specifications | |
Other part numbers | 02352HQD (CE9860-4C-EI-B mainframe ,4*subcard slots, 4*AC power modules, 5*fan modules, port-side intake) |
Installation Type | Cabinet Installation |
Depth [mm] | 765 mm |
Chassis height [U] | 4 |
Wide [mm] | 442 mm |
Height [mm] | 175 mm |
Weight with packaging [kg(lb)] | 51.0 kg (112.43 lb) |
Weight without packaging [kg(lb)] | 26.0 kg (57.32 lb) |
Maximum power consumption [W] | Configured with four CE98-D32CQ cards: 1627 W (ambient temperature: 40°C or 104°F; fan speed: 70%) Configured with four CE98-D8DQ cards: 1717 W (ambient temperature: 40°C or 104°F; fan speed: 100%) |
Typical power consumption [W] | Configured with four CE98-D32CQ cards: 1231 W (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 1289 W (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Static power consumption [W] | Configured with four CE98-D32CQ cards: 377 W Configured with four CE98-D8DQ cards: 548 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation [BTU/hour] | Configured with four CE98-D32CQ cards: 5553 BTU/hour (ambient temperature: 40°C or 104°F; fan speed: 70%) Configured with four CE98-D8DQ cards: 5861 BTU/hour (ambient temperature: 40°C or 104°F; fan speed: 100%) |
Typical heat dissipation [BTU/hour] | Configured with four CE98-D32CQ cards: 4202 BTU/hour (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 4400 TU/hour (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Static heat dissipation [BTU/hour] | Configured with four CE98-D32CQ cards: 1505 BTU/hour Configured with four CE98-D8DQ cards: 1871 BTU/hour |
Power supply mode | AC,DC,HVDC |
Rated input voltage [V] | - Rated input voltage range of 1200 W AC&240 V DC power modules: 100 V AC to 240 V AC; 50/60 Hz, DC: 240 V DC - 1200 W DC power module: -48 V DC: -48 V DC to -60 V DC, +48 V DC: +48 V DC |
Input voltage range [V] | - 1200 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1200 W DC power module: -48 V DC: -38.4 V DC to -72 V DC; +48 V DC: +38.4 V DC to +60 V DC |
Maximum input current [A] | - 1200 W AC&240 V DC power module: 10 A (100 V AC to 130 V AC); 8 A (200 V AC to 240 V AC); 8 A (240 V DC) - 1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC) |
Rated output power [W] | - 1200 W AC&240 V DC power module: 1200 W - 1200 W DC power module: 1200 W |
Maximum output power [W] | 1200 W AC&240 V DC 1200 W -48 V DC |
Memory | DRAM: 16 GB |
NOR Flash | 32 MB x 2 |
SSD Flash | 64 GB |
USB | Supported |
Console port | RJ45 |
Downlink Service interface | The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards: CE98-D32CQ: 32 x 100GE QSFP28 (100GE ports can be used as 40GE ports and cannot be split into 4 x 25GE and 4 x 10GE ports.) CE98-D8DQ: 8 x 400GE QSFP-DD (In V200R021C00, such ports can only work at 400 Gbit/s, cannot be used as 200GE, 100GE, or 40GE ports, and cannot be split. Specifically, they do not support the following split modes: 4 x 100GE, 2 x 200GE, 2 x 100GE, 2 x 40GE, 8 x 50GE, 8 x 25GE, 8 x 10GE, 4 x 50GE, 4 x 25GE, and 4 x 10GE. Auto-negotiation of 400GE copper cables is not supported and such cables can be used only for peer-link. In V200R021C10, such a 400GE port can be dynamically split into 2 x 200GE ports. Currently, only 2 x 200GE 5 m AOCs and 2.5 m copper cables are supported. By default, negotiation is disabled and cannot be enabled for copper cables. If an unsupported module is inserted into such a port, the system displays a message indicating a medium mismatch.) |
Service port supporting the stack function | Not supported |
RTC | Supported |
Switching capacity [bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | The device supports 4+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | 2+2 backup |
Number of power modules | 4 |
Power supply surge protection | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 5 |
Airflow direction | Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
MTBF [year] | 21.91 years |
MTTR [hour] | 3.43 hours |
Noise at high temperature (40°C, sound pressure) | Back-to-front airflow: < 76 dB(A) |
Noise at normal temperature (27°C, sound pressure) | Back-to-front airflow: < 59 dB(A) |
Availability | 0.9999934738 |
Model | Appearance |
CE9860-4C-EI-A | 4 U high, supporting four full-width flexible cards |
Model | Appearance |
CE98-D32CQ-A | 32-port 100GE/40GE QSFP28 line processing unit (LPU) |
CE98-D8DQ | 8-port 400GE QSFP-DD LPU |
CE98-D32CQ-F | 32-port 100GE QSFP28 LPU |
Item | CloudEngine 9860-4C-EI-A-4C-EI |
Port description | 4 slots, providing up to 128 x 100GE QSFP28 or 32 x 400GE QSFP-DD ports |
Switching capacity | 25.6 Tbit/s |
Packet forwarding rate | 8000 Mpps |
Airflow design | Standard back-to-front airflow |
Device virtualization | M-LAG |
Network convergence | Data Center Bridging Exchange Protocol (DCBX) and PFC |
Remote direct memory access (RDMA) and RoCE (RoCE v1 and RoCE v2) | |
Programmability | OPS programming |
Ansible-based automatic configuration and open-source module release | |
Traffic analysis | NetStream |
sFlow | |
VLAN | Access, trunk, and hybrid |
MAC address table | Automatic MAC address learning and aging |
Static, dynamic, and blackhole MAC address entries | |
Source MAC address filtering | |
MAC address learning limiting based on ports and VLANs | |
IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP |
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
IPv6 | IPv6 neighbor discovery (ND) |
Path MTU Discovery (PMTU) | |
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | |
Multicast | Multicast routing protocols, such as Internet Group Multicast Protocol (IGMP), Protocol Independent Multicast-Sparse Mode (PIM-SM), and Protocol Independent Multicast-Dense Mode (PIM-DM) |
Fast leaving of multicast member interfaces | |
Multicast traffic suppression | |
Reliability | Link Aggregation Control Protocol (LACP) |
STP, RSTP, VBST, and MSTP | |
BPDU protection, root protection, and loop prevention | |
Device Link Detection Protocol (DLDP) | |
VRRP, VRRP load balancing, and BFD for VRRP |
Item | CloudEngine 9860-4C-EI-A-4C-EI |
BFD for BGP, IS-IS, OSPF, and static routes | |
Traffic classification based on Layer 2 headers, Layer 3 headers, and Layer 4 protocol priorities | |
ACL, CAR, re-marking, and scheduling | |
QoS | Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR |
Congestion avoidance mechanisms such as WRED and tail drop |
Intelligent O&M | Network-wide path detection |
Telemetry | |
INT (IOAM) enhancement | |
Intelligent lossless network | PFC deadlock prevention |
AI ECN | |
Configuration and maintenance | Terminal access services such as console port login, Telnet, and SSH |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
Hot patches | |
User operation logs | |
ZTP | |
Security and management | Command line authority control based on user levels, preventing unauthorized users from using commands |
Defense against DoS, ARP, and ICMP attacks | |
Port isolation, port security, and sticky MAC | |
Binding of the IP address, MAC address, port number, and VLAN ID | |
Authentication methods, including AAA, RADIUS, and HWTACACS | |
RMON | |
Dimensions (H x W x D) | 175 mm x 442 mm x 765 mm |
Weight (full configuration) | 43.2 kg (including four power modules, four fan modules, and four cards) 33.04 kg (including four power modules and four fan modules) |
Environment requirements | Operating temperature: 0°C to 40°C (0 m to 1800 m) Storage temperature: -40°C to +70°C Relative humidity: 5% RH to 95% RH (noncondensing) |
Rated input voltage | Rated input voltage range of a 1200 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC 1200 W DC power module: -48C DC:-48 V DC to -60 V DC; +48 V DC: +48 V DC |
Input voltage range | 1200 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC 1200 W DC power module: -48 V DC: -38.4 V DC to -72 V DC; +48 V DC: +38.4 V DC to +60 V |
Active Device | ||
CE9860-4C-EI-A-B | CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, port-side intake) | |
CE9860-4C-EI-A-B1 | CE9860-4C-EI-A mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card,port-side intake) | |
CE9860-4C-EI-A | CE9860-4C-EI-A mainframe (4*subcard slots, without fan and power modules) | |
Subcard | ||
CE98-D32CQ-A | CE98: 32-port 100GE QSFP28 LPU | |
CE98-D8DQ | CE98: 8-port 400GE QSFP-DD LPU | |
CE98-D32CQ-F | CE98: 32-port 100GE QSFP28 Interface Card-1*1 | |
CE98-D8DQ-F | CE98: 8-port 400GE QSFP-DD Interface Card-1*1 | |
Power module | ||
Model | Description | Applicable product |
PAC1K2S12-PB | 1200W AC&240V DC Power Module (Back to Front,Power panel side exhaust) | CE9860-4C-EI-A |
PDC1K2S12-CE | 1200W DC Power Module (Back to Front,Power panel side exhaust) |
CE9860-4C-EI-A |
Fan module | ||
Active Device | ||
Model | Description | Applicable product |
FAN-180C-B | Fan box(B,FAN panel side exhaust) | CE9860-4C-EI-A |
Software | ||
N1-CE98LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 9800 | |
N1-CE98CFFD- SnS1Y | N1-CloudFabric Foundation SW License for CloudEngine 9800-SnS-Year | |
N1-CE98LIC-CFAD | N1-CloudFabric Advanced SW License for CloudEngine 9800 | |
N1-CE98CFAD-SnS1Y | N1-CloudFabric Advanced SW License for CloudEngine 9800-SnS-Year | |
N1-CE98LIC-CFPM | N1-CloudFabric Premium SW License for CloudEngine 9800 | |
N1-CE98CFPM-SnS1Y | N1-CloudFabric Premium SW License for CloudEngine 9800 -SnS-Year | |
N1-CE98LIC-AIF | N1-CloudEngine 9800 AI Fabric Function | |
N1-CE98AIF-SnS1Y | N1-CloudEngine 9800 AI Fabric Function-SnS-Year | |
N1-CE-F-LIC-DM | N1-CloudEngine Digital Map Function-Fixed | |
N1-CEFDM-SnS1Y | N1-CloudEngine Digital Map Function, Per Fixed device-SnS-Year | |
N1-CE-LIC-AFP1KVM | N1-CloudEngine Network Intelligent Analysis Flow Advantage Per 1000 VM,Electronic | |
N1-CEAFP1KVM-SnS1Y | N1-CloudEngine Network Intelligent Analysis Flow Advantage Per 1000 VM-SnSYear,Electronic | |
N1-CE-F-LIC-MDCA | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed | |
N1-CEFMDCA -SnS1Y | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed device-SnS-Year |
Packing:
1.Original Carton Package.
2. As your requirement.
Delivery:
1. 3-7 Working days after received the payment.
2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )
1.Quality: All products from HUA WEI and new.
2.Reply on time: Your inquiry related to our products or price will be replied within 24 hours.
3.OEM&ODM: We can help you to design and put your good idea into products.
4.Warranty: 1-years warranty.
5.Technology support: On-site technical support, Telemaintenance, Free call and E-mail technology supports.
6.Training service support: Provide free training service on installation and debugging technology supports.
Kuanlu Information Technology Co., Ltd(Kuanlu LTD)/HUA WEI Authorized agent. Kuanlu is a Global Provider of Telecommunication Equipment and Services.And Extending Business to ICT (Information and Communication Technology) Field. We buy&sell Original NEW&REF telecom equipment from carriers and market to other companies who need them.We offer carrier class telecommunication hardware at 80-90% OFF list. We provide network design&planning, configration, troubleshooting, maintenance and training service in world wide. Kuanlu Products& Stock More than $5million Hua wei products in stock.Delivery your order within 72hours base on quick response ability. Focus on High-end telecom products including IP Data,Transmission,Wireless,Server&Storage and spare parts. Most Kuanlu Employees are from Hua wei& Z TE. Sales team over 5years experience advise you select products. Engineers team over 5years experience offer remote or local installation and configuration service. Expert team over 10years experience help you plan your network.
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.