| Customization: | Available |
|---|---|
| Type: | Wireless |
| Network Site: | Border Router |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 02350FWP |
Model | CR5P03BASA75 |
Description | CR5P03BASA75 Integrated AC Chassis Components, Including Dual AC Power |

Technical Specifications[mm] | |
Height[mm] | 264 mm |
Depth[mm] | 710 mm |
Wide[mm] | 442 mm |
Chassis height[U] | 6U |
Weight without packaging (full configuration)[kg(lb)] | 74.7 kg (164.71 lb) |
Weight without packaging[kg(lb)] | 37 kg (81.57 lb) |
Maximum power consumption (with configuration)[W] | 1740 W (fully loaded with LPUF-200s) |
Typical power consumption (with configuration)[W] | 1120 W (fully configured with LPUF-200s) |
Maximum heat dissipation (with configuration)[BTU/hour] | 5415.9 BTU/hour (fully loaded with LPUF-200s) |
Typical heat dissipation (with configuration)[BTU/hour] | 3633.8 BTU/hour (fully configured with LPUF-200s) |
Power supply mode | AC |
Input voltage range[V] | 180 V to 264 V |
Rated input voltage[V] | 200 V to 240 V |
Maximum input current[A] | 16 A/single-module |
Number of service board slots | 3 |
Number of slots | 5 |
Switching capacity[bps,bit/s] | 2.76 Tbit/s |
Redundant fans | Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Redundant MPUs | 1:1 |
Redundant power supply | 1+1 |
Noise at normal temperature (acoustic power)[dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Airflow direction | Left-to-back airflow. |
Maximum number of power chassis inputs | (1 channel/PEM)*2 PEM = 2 channels |
Maximum input cable size | Standard C19 cable |
Front-end circuit breaker/fuse | 16 A |
Short-term operating temperature[°C(°F)] | –5°C to +55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate[°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Long-term operating temperature[°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Storage temperature[°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity[RH] | 5% RH to 85% RH, non-condensing |
Storage relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Short-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude[m(ft.)] | ≤ 4000 m (13123.36 ft.) (From 1800 m to 4000 m [5905.51 ft. to 13123.36 ft.], the operating temperature of the device decreases by 1°C [1.8°F] for every 220 m [721.78 ft.] increase in altitude.) |
Storage altitude[m(ft.)] | < 5000 m (16404.2 ft.) |
MTBF[year] | 22.85 |
MTTR[hour] | 0.5 |
Availability | 0.999997502 |