| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 02355NEH |
Model | CloudEngine S5755-H48UN4Y2CZ |
Description | S5755-H48UN4Y2CZ (48*10/100/1000/2.5GBASE-T ports, 4*25GE SFP28 ports, 2*100GE QSFP28 ports, expansion card slot, PoE++, without power module) |




Technical Specifications | |
Chassis material | Metal |
Height[mm] | 43.6 mm |
Depth[mm] | 420.0 mm |
Wide[mm] | 442.0 mm |
Chassis height[U] | 1 |
Weight with packaging[kg(lb)] | 9.89 kg (21.8 lb) |
Weight without packaging[kg(lb)] | 6.81 kg (15.01 lb) |
Maximum power consumption[W] | - 100% traffic under the ATIS standard, dual power modules, and without PoE: - 151 W (all ports used) - 141 W (2 x 100GE ports not used) - Full PoE load, three 1000 W power modules: 3022 W (PoE: 2820 W) |
Typical power consumption[W] | 30% traffic under the ATIS standard, dual power supplies: - 135 W (all ports used ) - 125 W (2 x 100GE ports not used) |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Maximum heat dissipation[BTU/hour] | - 100% traffic under the ATIS standard, dual power modules, and without PoE: - 515.23 (all ports used) - 481.11 (2 x 100GE ports not used) - Full PoE load, three 1000 W power modules: 10311.37 |
Typical heat dissipation[BTU/hour] | 30% traffic under the ATIS standard, dual power supplies: - 460.63 (all ports used ) - 426.51 (2 x 100GE ports not used) |
Power supply mode | Pluggable power supply |
Input voltage range[V] | - AC input: 90 V AC to 290 V AC; 45 Hz to 66 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC |
Rated input voltage[V] | - AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: –48 V DC to –60 V DC |
Maximum input current[A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Number of power slots | 3 |
Number of card slots | 1 |
Memory | 4 GB |
Flash memory | Physical space: 2 GB |
Redundant power supply | 1+1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Types of fans | Pluggable |
Noise at normal temperature (acoustic power)[dB(A)] | 30% PoE load: 52.90 dBA |
Noise at normal temperature (acoustic pressure)[dB(A)] | 30% PoE load: 40.9 dBA |
Airflow direction | Air intake from left, front, and right and air exhaust from rear |
Storage temperature[°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Short-term operating temperature[°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Long-term operating temperature[°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Restriction on the operating temperature variation rate[°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: - The operating temperature exceeds 45°C (113°F) for no more than 96 consecutive hours in a year. - The total time in which the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. |
Long-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Storage altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating altitude[m(ft.)] | 0–5000 m (0–16404 ft.) |
MTBF[year] | 56.34 |
MTTR[hour] | 2 |
Availability | > 0.99999 |
Maximum number of physical ports on the entire device | 54 |
Maximum number of 100GE ports | 2 |
Maximum number of 40GE ports | 2 |
Maximum number of 25GE ports | 4 |
Maximum number of 10GE ports | 4 |
Maximum number of GE ports | 52 |
Maximum number of FE ports | 48 |
100G optical interface | 2 |
25G optical interface | 4 |
USB | Supported |
Console port | RJ45 |
Eth Management port | RJ45 |
Power supply surge protection | - Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode - Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode |
RPS input | Not supported |