Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
![]() |
Description | CE6860-SAN switch (48*25GE SFP28, 8*100GE QSFP28, without fan and power modules) |
Part Number | 02354FPM/02354FPN /02354FPP | |
Model |
|
|
First supported version |
|
![]() |
![]() |
![]() |
![]() |
Dimensions with packaging (H x W x D) [mm (in.)] | 225 mm x 860 mm x 650 mm (8.86 in. x 33.86 in. x 25.59 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | - Basic dimensions (the depth excludes the parts protruding from the body): 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.40 in. x 16.54 in.) - Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442 mm x 445 mm (1.72 in. x 17.40 in. x 17.52 in.) |
Weight without packaging [kg (lb)] | 6.7 kg (14.8 lb), excluding optical modules, power modules, and fan modules |
Weight without packaging (full configuration) [kg (lb)] | 8.7 kg (19.2 lb) (including AC power modules and fan modules, excluding optical modules) |
Weight with packaging [kg (lb)] | 11.9 kg (26.24 lb) |
Weight with packaging (full configuration) [kg (lb)] | 13.9 kg (30.64 lb) |
Chassis height [U] | 1 |
Installation Type | Cabinet Installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 4-core, 1.4 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Power supply mode | AC,DC,HVDC |
Console port | RJ45 |
Downlink Service interface | 48 x 25GE SFP28/48 x 50GE SFP56 1. 25GE ports can be used as 10GE ports. 50GE ports can be used as 25GE ports but not 10GE or GE ports. 2. When 25GE ports are upgraded to 50GE ports, eight ports form a group. Note: 1. Support for optical modules: (1) In the case of port-side air intake, downlink ports support 10G-AOC/SR/LR/ER/ZR and 25G-AOC/SR/LR. (2) In the case of port-side air exhaust, downlink ports support 10G-AOC/SR/LR and 25G-AOC/SR/LR. 2. Support for copper cables: When 50GE copper cables are used, contact Hua wei engineers for interconnection verification. |
Uplink Service interface | 8 x 100GE QSFP28/8 x 200GE QSFP56 1. Each 100GE port can be configured as a 40GE port, and each 200GE port can be configured as a 100GE/40GE port. 2. When 100GE ports are upgraded to 200GE, four such ports form a group. 3. 100GE ports are divided into groups 1 to 4 and 5 to 8. Four ports in each group are split together. Ports 2, 4, 6, and 8 can be split into four 25GE ports (whose speeds can be set to 10 Gbit/s). After the split, ports 1, 3, 5, and 7 cannot be used. A 100GE port cannot be split into 2 x 50GE (50GE: 2 x 25GE) ports. 4. 200GE ports cannot be split. Note: 1. Support for optical modules: (1) In the case of port-side air intake, 100GE/200GE ports support 100G-AOC/SR4/CWDM4/LR4/4WDM. (2) In the case of port-side air exhaust, 100GE/200GE ports support 100G-AOC/SR4/CWDM4/LR4 optical modules, but do not support 50GE and 200GE optical modules. 2. Support for copper cables: When 200GE copper cables are used, contact Hua wei engineers for interconnection verification. |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] | - 48 x 50G + 8 x 200G: 374 W (50% throughput, copper cables on all ports, normal temperature, dual power modules) - 48 x 25G + 8 x 100G: 360 W (50% throughput, copper cables on all ports, normal temperature, dual power modules), 407 W (50% throughput, short-distance optical modules on all ports, normal temperature, dual power modules) |
Typical heat dissipation [BTU/hour] | - 48 x 50G + 8 x 200G: 1277 BTU/hour (50% throughput, copper cables on all ports, normal temperature, dual power modules) - 48 x 25G + 8 x 100G: 1229 BTU/hour (50% throughput, copper cables on all ports, normal temperature, dual power modules), 1389 BTU/hour (50% throughput, short-distance optical modules on all ports, normal temperature, dual power modules) |
Static power consumption [W] | 322 W |
Static heat dissipation [BTU/hour] | 1100 BTU/hour |
Maximum power consumption [W] | - 48 x 50G + 8 x 200G: 619 W (100% throughput, downlink 2 W 50G optical modules, uplink 6.5 W 200G optical modules, 40°C, dual power modules) - 48 x 25G + 8 x 100G: 544 W (100% throughput, downlink 1.5 W 25G optical modules, uplink 5 W 100G optical modules, 40°C, dual power modules) |
Maximum heat dissipation [BTU/hour] | - 48 x 50G + 8 x 200G: 2110 BTU/hour (100% throughput, downlink 2 W 50G optical modules, uplink 6.5 W 200G optical modules, 40°C, dual power modules) - 48 x 25G + 8 x 100G: 1858 BTU/hour (100% throughput, downlink 1.5 W 25G optical modules, uplink 5 W 100G optical modules, 40°C, dual power modules) |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | - 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1000 W DC power module: -48 V DC to -60 V DC - 1200 W high-voltage DC power module: 240 V DC to 380 V DC |
Input voltage range [V] | - 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1000 W DC power module: -38.4 V DC to -72 V DC - 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A] | - 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) - 1000 W DC power module: 30 A (-48 V DC to -60 V DC) - 1200 W high-voltage DC power module: 8 A |
Rated output power [W] | - 600 W AC&240 V DC power module: 600 W - 1000 W DC power module: 1000 W - 1200 W high-voltage DC power module: 1200 W |
Certification | - Complies with safety standards. - Complies with EMC standards. - Complies with environmental protection standards. |
Power supply surge protection [kV] | - AC power supply protection: 6 kV in common mode and 6 kV in differential mode - 240 V HVDC power supply protection: 4 kV in common mode and 2 kV in differential mode - -48 V DC power supply protection: 4 kV in common mode and 2 kV in differential mode - 380 V HVDC power supply protection: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Redundant fans | The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Availability | 0.9999943515 |
MTBF [year] | 30.32 years |
MTTR [hour] | 1.5 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | - Front-to-back airflow: 49.8 dB(A) on average (maximum: 53.6 dB(A)) - Back-to-front airflow: 47.8 dB(A) on average (maximum: 51.2 dB(A)) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | - Front-to-back airflow: 67.6 dB(A) on average (maximum: 73.4 dB(A)) - Back-to-front airflow: 68 dB(A) on average (maximum: 75.4 dB(A)) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
RTU License Supported | Yes. By default, only 24 of the 48 x 25GE ports are enabled and can work only at 25 Gbit/s, and the eight 100GE ports can work only at 100 Gbit/s. The following RTU licenses can be used: 88036XTL: 24 x 25GE ports are added. 88036YCK: The speed of 24 x 25GE ports is upgraded to 50 Gbit/s. 88036YCL: The speed of eight 100GE ports is upgraded to 200 Gbit/s. |
BOM Number
|
License Query
|
Abbreviation
|
Description
|
---|---|---|---|
88036QEJ |
CE6800 RDMA application acceleration function package 2 |
N1-CE68LIC-AFRD-2 |
Controlled features: The AI ECN, iQCN, and TCP FlexBuffer (TCP acceleration) functions |
88037HEM |
CE6800 Antilocking PFC (ABS PFC) function |
CE68-LIC-ABS |
Controlled features: Antilocking PFC (ABS PFC) function |
88061HBY |
Annual fee of the packet loss and latency visualization function package of the CE6800 |
N1-CE68PLLV-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88036RYH |
N1 UPG-A-P upgrade package of the CE6800 |
N1-CE68UPG-A-P |
Controlled features: The iMaster NCE-Fabric intent standard package, FabricInsight network traffic analysis, AnyFlow, packet loss and latency visualization, iMaster NCE-Fabric digital map standard package, iMaster NCE-Fabric per virtual network system - digital map scenario package, and FabricInsight IFIT service assurance functions |
88038QKJ |
AI Fabric HPC scenario value-added package of the CE6800 |
N1-CE68LIC-HPC |
Controlled features: The AI ECN, iQCN, TCP FlexBuffer (TCP acceleration), and Rail Group functions |
88036YCL |
RTU for upgrading 32x100GE ports to 32x200GE ports on the CE6800 |
CE68-RTU-U8CQ |
When the license is not activated, a 100GE port can work only at the rate of 100 Gbit/s by default. |
88060BSM |
Annual fee of the N1 foundation function package on the CE6800 |
N1-CE68CFFD-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88035UQQ |
CE6800 enhanced function package A |
N1-CE68LIC-ADA |
Controlled features: The telemetry, IOAM, and 1588v2 (PTP) functions |
88060QCW |
Annual fee of the N1 management function package on the CE6800 |
N1-CE68CFMM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060QBY |
Annual fee of the NE router management by iMaster NCE-Fabric |
N1-CEFCFGW-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037NPK |
CE6800 cloud data center network software package |
CDCN-LIC-68-FD |
Controlled features: CE6800 management through iMaster NCE-Fabric, FabricInsight network intelligent basic analysis, PNF basic software, telemetry, IOAM, 1588v2 (PTP), VXLAN, M-LAG upgrade in maintenance mode, and virtual peering M-LAG functions |
88061EFH |
Annual fee of the N1 UPG-F-A upgrade package of the CE6800 |
N1-CE68UGFA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88061LHX |
Annual fee of the N1 UPG-A-P upgrade package of the CE6800 |
N1-CE68UGAP-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060BSR |
Annual fee of the AI fabric function package on the CE6800 |
N1-CE68AIF-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88039ANW |
CE6800 enhanced package for the centralized storage scenarios |
N1-CE68LIC-NOF-ENHANCED |
Controlled features: The basic software, telemetry, FabricInsight network intelligent basic analysis, AI ECN, iQCN, iNOF, service telemetry, M-LAG upgrade in maintenance mode, NPCC, antilocking PFC (ABS PFC), FabricInsight network health, FabricInsight IFIT-based service assurance, and IFIT functions |
88038CPK |
Annual fee of the Value-added package of specified flow analysis (per 1000 VMs) |
N1-CEAFP1KVM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88036TQN |
CE6800 M-LAG upgrade in maintenance mode |
CE68-LIC-LU |
Controlled feature: M-LAG upgrade in maintenance mode function |
88035UPQ |
N1 management function package of the CE6800 |
N1-CE68LIC-CFMM |
Controlled features: The basic software, VXLAN, M-LAG upgrade in maintenance mode, and virtual peering M-LAG functions |
88035PVD |
Security function package of the CE6800 |
N1-CE68LIC-SEC |
Controlled features: MACsec function |
88036KVS |
N1 UPG-F-A upgrade package of the CE6800 |
N1-CE68UPG-F-A |
Controlled features: The FabricInsight network health, multicast NAT, iMaster NCE-Fabric OPP scenario package, IFIT, iMaster NCE-Fabric multi-cloud and multi-DC scenario package, FabricInsight multi-cloud and multi-DC analysis scenario package, TCP FlexBuffer (TCP acceleration), PIM FRR (MoFRR), and DPFR functions |
88034VUP |
1588v2 (PTP) function of the CE6800 |
CE68-LIC-PTP |
Controlled feature: 1588v2 (PTP) function |
88038QGG |
Value-added package of xFlow intelligent full-flow analysis, 40Gbps, 15Mpps, 1.8M Flow Per Second |
N1-CE-LIC-XFLOW40G |
Controlled features: The xFlow intelligent full-flow analysis (40Gbps, 15Mpps, 1.8M Flow Per Second) function |
88063TLY |
Annual fee of the CE6800 standard package for the centralized storage scenarios |
N1-CE68NOFSTANDARD-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88036QEL |
CE6800 NOF+ storage value-added package |
N1-CE68LIC-NOF+ |
Controlled features: The AI ECN, iQCN, iNOF, service telemetry, NPCC, and TCP FlexBuffer (TCP acceleration) functions |
88036XTL |
RTU for upgrading 32x100GE ports to 32x200GE ports on the CE6800 |
CE68-RTU-24XS |
When the license is not activated, 24x25GE+8x100GE ports can be used, and other ports are unavailable by default. |
88036TQQ |
CE6800 NPCC function |
CE68-LIC-NPCC |
Controlled features: NPCC function |
88062SNB |
Annual fee of the digital map function package |
N1-CEFDM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037HGJ |
CE6800 NOF+ storage long-distance enhanced package |
N1-CE68LIC-NOFA |
Controlled features: The antilocking PFC (ABS PFC) function |
88063MWC |
Annual fee of the digital map function package(1000 NEs) |
N1-CEFDM1000-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060PKK |
Annual fee of the N1 FabricInsight network intelligent basic analysis on the CE6800 |
N1-CEFFIF-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required |
![]() |
Packing: 1. Original Carton Package. 2. As your requirement. |
![]() |
Delivery: 1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software.
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.