Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Part Number | 02351RFJ | |
Model | CE8850-EI-F-B0B | |
Description | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,3*FAN Box,Port-side Exhaust) |
hardware specifications
Technical Specifications | |
Other part numbers | 02351RFF-004 (CE8850-64CQ-EI Switch (64-Port 100GE QSFP28,Without Fan and Power Module)) 02351RFH-004 (CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,3*FAN Box,Port-side Intake)) |
Installation Type | Cabinet installation |
Depth [mm] | 600.0 mm |
Chassis height [U] | 2 |
Wide [mm] | 442.0 mm |
Height [mm] | 86.1 mm |
Weight with packaging [kg(lb)] | 22.3 kg (49.16 lb) |
Weight without packaging [kg(lb)] | 12 kg (26.46 lb) (excluding optical modules, power modules, and fan modules) |
Maximum power consumption [W] | 629 W (100% traffic load, QSFP28 short-distance optical modules on 64 ports, normal temperature, dual AC power modules) 965 W (100% traffic load, QSFP28 long-distance optical modules on 64 ports, 40°C or 104°F, dual AC power modules) |
Typical power consumption [W] | 376 W (100% traffic load, QSFP28 high-speed cables on 32 ports, normal temperature, dual AC power modules) 455 W (100% traffic load, QSFP28 short-distance optical modules on 32 ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 302 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation [BTU/hour] | 2147 BTU/hour (100% traffic load, QSFP28 short-distance optical modules on 64 ports, normal temperature, dual AC power modules) 3293 BTU/hour (100% traffic load, QSFP28 long-distance optical modules on 64 ports, 40°C or 104°F, dual AC power modules) |
Typical heat dissipation [BTU/hour] | 1283 BTU/hour (100% traffic load, QSFP28 high-speed cables on 32 ports, normal temperature, dual AC power modules) 1553 BTU/hour (100% traffic load, QSFP28 short-distance optical modules on 32 ports, normal temperature, dual AC power modules) |
Static heat dissipation [BTU/hour] | 1031 BTU/hour |
Power supply mode | AC,DC,HVDC |
Rated input voltage [V] | - 1200 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1200 W DC power module: -48 V DC to -60 V DC; +48 V DC |
Input voltage range [V] | - 1200 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1200 W DC power module: -38.4 V DC to -72 V DC; +38.4 V DC to +72 V DC |
Maximum input current [A] | - 1200 W AC&240 V DC power module: 10 A (100 V AC to 130 V AC); 8 A (200 V AC to 240 V AC); 8 A (240 V DC) - 1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC) |
Rated output power [W] | - 1200 W AC&240 V DC power module: 1200 W - 1200 W DC power module: 1200 W |
Memory | DRAM: 4 GB |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
USB | Supported |
Console port | RJ45 |
Downlink Service interface | 64*40GE/100GE QSFP28 Ethernet optical ports (Note: A QSFP28 Ethernet optical port can be split into four 10GE or 25GE ports. A 100GE port can be split into two 50GE ports. This function is available only to QSFP28-100G-SR4 optical modules.) |
Uplink Service interface | 2 x 10GE SFP+ Ethernet optical ports (Note: This port is unavailable currently and is reserved for future function expansion.) |
Service port supporting the stack function | 100GE optical port |
RTC | Supported |
Switching capacity [bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | 1+1 backup |
Number of power modules | 2 |
Power supply surge protection | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 3 |
Airflow direction | Front-to-back or back-to-front airflow, depending on the selected fan modules and power modules |
Storage temperature [°C(°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
MTBF [year] | 20.71 years |
MTTR [hour] | 1.85 hours |
Noise at high temperature (40°C, sound pressure) | Front-to-back airflow: 82.5 dB(A) on average (maximum: 87.4 dB(A)) Back-to-front airflow: 79.7 dB(A) on average (maximum: 85.6 dB(A)) |
Noise at normal temperature (27°C, sound pressure) | Front-to-back airflow: 61.5 dB(A) on average (maximum: 65.9 dB(A)) Back-to-front airflow: 61.3 dB(A) on average (maximum: 66.5 dB(A)) |
Availability | 0.999992477 |
Item | CloudEngine 8850-64CQ-EI |
Device virtualization | Intelligent stack (iStack) |
M-LAG | |
Data center interconnect (DCI) | VXLAN mapping, enabling Layer 2 interconnection between DCs |
Network virtualization | VXLAN routing and VXLAN bridging |
BGP-EVPN | |
TRILL (supported only by the CloudEngine 8850-64CQ-EI) | |
QinQ access VXLAN | |
SDN | iMaster NCE-Fabric |
Network convergence | Fibre Channel over Ethernet (FCoE) |
Data Center Bridging Exchange Protocol (DCBX), Priority-based Flow Control (PFC), and expanded trunking system (ETS) | |
Remote direct memory access (RDMA) and RoCE (RoCEv1 and RoCEv2) | |
Programmability | OPS programming |
Ansible-based automatic configuration and open-source module release | |
Traffic analysis | NetStream |
sFlow | |
VLAN | Access, trunk, and hybrid ports |
Default VLAN | |
QinQ | |
MUX VLAN | |
GARP VLAN Registration Protocol (GVRP) | |
Multicast | Multicast routing protocols, such as the Internet Group Multicast Protocol (IGMP), Protocol Independent |
Multicast-Sparse Mode (PIM-SM), Protocol Independent Multicast-Dense Mode (PIM-DM), Multicast Source Discovery Protocol (MSDP), and Multicast BGP (MBGP) | |
IGMP snooping | |
IGMP proxy | |
Fast leaving of multicast member interfaces | |
Multicast traffic suppression | |
Multicast VLAN | |
Multicast VXLAN | |
MPLS | Basic MPLS |
Reliability | Link Aggregation Control Protocol (LACP) |
STP, RSTP, VBST, and MSTP | |
BPDU protection, root protection, and loop prevention | |
Smart Link and multi-instance | |
Device Link Detection Protocol (DLDP) | |
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms | |
G.8032 Ethernet Ring Protection Switching (ERPS) | |
VRRP, VRRP load sharing, and BFD for VRRP | |
BFD for BGP, IS-IS, OSPF, and static routing | |
BFD for VXLAN | |
QoS | Traffic classification based on Layer 2 protocol headers, Layer 3 protocol headers, and Layer 4 protocol priorities |
ACL, CAR, re-marking, and scheduling | |
Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR | |
Congestion avoidance mechanisms such as WRED and tail drop | |
Traffic shaping | |
Intelligent O&M | Network-wide path detection |
1588v2 (supported only by the CloudEngine 8850-64CQ-EI) | |
Telemetry | |
INT (IOAM) and enhanced ERSPAN | |
Intelligent traffic analysis | |
RoCE traffic visualization: RoCE traffic KPI analysis | |
Statistics collection on the buffer microburst status | |
VXLAN OAM: VXLAN ping and VXLAN tracert | |
Intelligent lossless network | PFC deadlock prevention |
AI ECN: The switch intelligently adjusts the ECN thresholds of lossless queues based on the live-network traffic model. | |
Fast CNP: The switch directly sends CNP packets to server NICs at the source end to shorten the CNP feedback path. | |
DLB | |
ECN overlay | |
INC (supported only by the CE8850-64CQ-EI) | |
Configuration and maintenance | Terminal login through the console port, Telnet, and SSH |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
802.3az Energy Efficient Ethernet (EEE) | |
Security and management | 802.1X authentication |
Command line authority control based on user levels, preventing unauthorized users from using commands | |
Defense against DoS, ARP, and ICMP attacks | |
Port isolation, port security, and sticky MAC | |
Binding of the IP address, MAC address, port ID, and VLAN ID | |
Authentication methods, including AAA, RADIUS, and HWTACACS | |
RMON |
BOM Number
|
License Query
|
Abbreviation
|
Description
|
---|---|---|---|
88036RYF |
N1 UPG-A-P upgrade package of the CE8800 |
N1-CE88UPG-A-P |
Controlled features: The iMaster NCE-Fabric intent standard package, FabricInsight network flow analysis, IFIT, iMaster NCE-Fabric digital map standard package, iMaster NCE-Fabric per virtual network system - digital map scenario package, and FabricInsight IFIT service assurance functions |
88036KVQ |
N1 UPG-F-A upgrade package of the CE8800 |
N1-CE88UPG-F-A |
Controlled features: FabricInsight network health, iMaster NCE-Fabric multi-cloud multi-DC scenario package, FabricInsight multi-cloud multi-DC analysis scenario package, enhanced DAD in a stack, and iMaster NCE-Fabric OPP scenario package functions |
88061EFF |
Annual fee of the N1 UPG-F-A upgrade package of the CE8800 |
N1-CE88UGFA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88038CPK |
Value-added package of specified flow analysis (per 100 VMs) |
N1-CE-LIC-AFP100VM |
Controlled features: The specified flow analysis (per 100 VMs) function |
88037RGT |
CE8800 IFIT function |
CE88-LIC-IFIT |
Controlled features: IFIT function |
88033DNJ |
FCF for all ports of the CE8800 |
CE88-LIC-FCFAL |
Controlled feature: FCF function |
88035TFC |
N1 FabricInsight network intelligent basic analysis of the CE8800 |
N1-CE-F-LIC-FIF |
Controlled features: FabricInsight network intelligent basic analysis and Telemetry functions |
88038CPK |
Annual fee of the Value-added package of specified flow analysis (per 100 VMs) |
N1-CEAFP100VM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88035DWP |
N1 foundation function package of the CE8800 |
N1-CE88LIC-CFFD |
Controlled features: CE8800 management by iMaster NCE-Fabric, the FabricInsight network intelligent basic analysis, basic software , Telemetry, discarded packet capture, IOAM, 1588v2 (PTP), VXLAN functions |
88060QDN |
Annual fee of the enhanced function package A of the CE8800 |
N1-CE88ADA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88035TFH |
N1 FabricInsight network intelligent value-added analysis of the CE8800 (per 1000 VMs) |
N1-CE-LIC-FIA-1KVM |
Controlled features: FabricInsight network intelligent value-added analysis (per 1000 VMs) function |
88061LJL |
Annual fee of the N1 premium function package of the CE8800 |
N1-CE88CFPM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037XYJ |
CE8800 AI Fabric RDMA application acceleration function package |
N1-CE88LIC-AFRD |
Controlled feature: Buffer optimization for lossless queues, differentiated flow scheduling, dynamic ECN, AI ECN, and fast CNP functions |
88035DWR |
N1 advanced function package of the CE8800 |
N1-CE88LIC-CFAD |
Controlled features: CE8800 management by iMaster NCE-Fabric, the FabricInsight network intelligent basic analysis, FabricInsight network health, basic software , Telemetry, discarded packet capture, IOAM, 1588v2 (PTP), VXLAN, iMaster NCE-Fabric multi-cloud multi-DC scenario package, FabricInsight multi-cloud multi-DC analysis scenario package, enhanced DAD in a stack, and iMaster NCE-Fabric OPP scenario package functions |
88038CPJ |
Digital map function package |
N1-CE-F-LIC-DM |
Controlled features: The iMaster NCE-Fabric digital map standard package and iMaster NCE-Fabric per virtual network system - digital map scenario package function |
88062SNB |
Annual fee of the digital map function package |
N1-CEFDM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88038CPK |
Value-added package of specified flow analysis (per 1000 VMs) |
N1-CE-LIC-AFP1KVM |
Controlled features: The specified flow analysis (per 1000 VMs) function |
88033DNH |
FCF for 16 ports of the CE8800 |
CE88-LIC-FCF16 |
Controlled feature: FCF function |
88060QCU |
Annual fee of the N1 management function package on the CE8800 |
N1-CE88CFMM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88038QGG |
Value-added package of xFlow intelligent full-flow analysis, 40Gbps, 15Mpps, 1.8M Flow Per Second |
N1-CE-LIC-XFLOW40G |
Controlled features: The xFlow intelligent full-flow analysis (40Gbps, 15Mpps, 1.8M Flow Per Second) function |
Active Device | |
CE8850-EI-F-B0B | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,Port-side Exhaust) |
CE8850-EI-B-B0B | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,Port-side Intake) |
CE8850-64CQ-EI | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,Without Fan and Power Module) |
CE8850E-32CQ-EI | CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,without fan and power module) |
CE8850E-32CQ-EI-B | CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,2*AC power module,4*fan module,portside intake) |
CE8850E-32CQ-EI-F | CE8850E-32CQ-EI Switch(32*100GE QSFP28, 1*10GE SFP+, 2*AC power module,4*fan module, port-side exhaust) |
Power module | ||
Model | Description | Applicable product |
PHD-1K2WA-F | 1200W HVDC Power Module(Power panel side intake) | CE8850-64CQ-EI |
PHD-1K2WA-B | 1200W HVDC Power Module(Power panel side exhaust) | CE8850-64CQ-EI |
PDC-1K2WA-B | 1200W DC Power Module(Power panel side intake) | CE8850-64CQ-EI |
PDC-1K2WA-F | 1200W DC Power Module(Power panel side exhaust) | CE8850-64CQ-EI |
PAC1K2S12-PB | 1200W AC&240V DC Power Module (Back to Front,Power panel side exhaust) | CE8850-64CQ-EI |
PAC1K2S12-PF | 1200W AC&240V DC Power Module (Front to Back,Power panel side intake) | CE8850-64CQ-EI |
PHD1K2S12-DB | 1200W HVDC Power Module (Back to Front,Power panel side exhaust) | CE8850E-32CQ-EI |
PDC1000S12-DB | 1000W DC Power Module (Power panel side exhaust) | CE8850E-32CQ-EI |
PDC1000S12-DF | 1000W DC Power Module (Power panel side intake) | CE8850E-32CQ-EI |
PAC600S12-EB | 600W AC&240V DC Power Module (Back to Front,Power panel side exhaust) | CE8850E-32CQ-EI |
PAC600S12-EF | 600W AC&240V DC Power Module (Front to Back,Power panel side intake) | CE8850E-32CQ-EI |
Fan module | ||
Model | Description | Applicable product |
FAN-180A-F | Fan box(F,FAN panel side intake) | CE8850-64CQ-EI |
FAN-180A-B | Fan box(B,FAN panel side exhaust) | CE8850-64CQ-EI |
FAN-031A-F | Fan box(F,FAN panel side intake) | CE8850E-32CQ-EI |
FAN-031A-B | Fan box(B,FAN panel side exhaust) | CE8850E-32CQ-EI |
Software | ||
CE88-LIC-BUN01 | CE8800 Function License Bundle 1 | |
CE88-LIC-TLM | CE8800 Telemetry Function | |
CE88-LIC-PTP | CE8800 PTP Function (supported only by the CE8850-64CQ-EI) | |
CE88-LIC-AIF | CloudEngine 8800 AI Fabric Function | |
N1-CE88LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 8800 | |
N1-CE88CFFD-SnS1Y | N1-CE8800 CloudFabric Foundation Software Package-Subscription and Support-Year | |
N1-CE88LIC-CFAD | N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year | |
Active Device | ||
N1-CE88CFAD-SnS1Y | N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year | |
N1-CE88LIC-CFPM | N1- CloudEngine 8800 CloudFabric Premium Software Package | |
N1-CE88CFPM-SnS1Y | N1- CloudEngine 8800 CloudFabric Premium Software Package-Subscription and Support-Year | |
N1-CE88LIC-AIF | N1-CloudEngine 8800 AI Fabric Function | |
N1-CE88AIF-SnS1Y | N1-CE8800 AI Fabric Function-Subscription and Support-Year | |
N1-CE88LIC-HPC | N1-CloudEngine 8800 AI Fabric HPC Scenario Value-added Package | |
N1-CE88HPC-SnS1Y | N1-CloudEngine 8800 AI Fabric HPC Storage Scenario Value-added Package-Subscription and Support-Year |
|
N1-CE-F-LIC-MDCA | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed |
N1-CEFMDCA -SnS1Y | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed DeviceSubscription and Support-Year |
N1-CE88UPG-F-A | N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced |
N1-CE88UGFA-SnS1Y | N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced- Subscription and Support-Year |
N1-CE88UPG-A-P | N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium |
N1-CE88UGAP-SnS1Y | N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium-Subscription and Support-Year |
Packing: 1. Original Carton Package. 2. As your requirement. |
|
Delivery: 1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software
After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu. |
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu. |
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.