| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 02352RCU |
Model | CE16804 |
Description | CE16804 AC&high-voltage DC assembly chassis |




Technical Specifications[mm] | |
Depth[mm] | 874 mm |
Chassis height[U] | 9.8 |
Wide[mm] | 442 mm |
Height[mm] | 438 mm |
Weight with packaging[kg(lb)] | 138 kg (304.23 lb) |
Weight without packaging[kg(lb)] | 94.1 kg (207.49 lb) (including two MPUs and filler panels) |
Heat dissipation mode | Heat dissipation using fans |
Power supply mode | AC/HVDC pluggable |
Rated input voltage[V] | - AC: 220 V; 50 Hz/60 Hz - High-voltage DC (HVDC): 240 V/380 V |
Input voltage range[V] | - AC: 176–290 V; 45–65 Hz - High-voltage DC (HVDC): 188 V to 288 V or 260 V to 400 V |
Maximum input current[A] | - AC: 16 A @ 200 V; 18.5 A @ 176 V - High-voltage DC (HVDC): 18 A @ 188 V; 13 A @ 260 V |
Maximum output power[W] | - In 5+1 backup mode: 3000 W x 5 = 15000 W - In 6+0 backup mode: 3000 W x 6 = 18000 W |
Switching capacity[bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | - Dual-input power supply system: N+1 backup is recommended. - Single-input power supply system: N+1 backup Dual-input power supply is recommended to ensure reliability. |
Redundant Switch fabrics | N+M |
Redundant MPUs | 1:1 |
Number of power modules | 6 |
Airflow direction | Front-to-back airflow |
Storage temperature[°C(°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Long-term operating temperature[°C(°F)] | 0°C to 40°C (32°F to 104°F) |
Storage relative humidity[RH] | 5% to 95% RH, non-condensing |
Long-term operating relative humidity[RH] | 5% RH to 85% RH, noncondensing |
Storage altitude[m(ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating altitude[m(ft.)] | ≤ 5000 m (16404 ft.) When the altitude is between 1800 m and 5000 m (5906 ft. and 16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
MTBF[year] | 34.93 years |
MTTR[hour] | 1 hour |
Number of LPU slots | 4 |
Number of SFU slots | 9 |
Number of MPU slots | 2 |
Number of slots | 15 |
Availability | 0.9999971695 |