Chassis material |
Metal |
Height [mm] |
43.6 mm |
Depth [mm] |
420.0 mm |
Wide [mm] |
442.0 mm |
Chassis height [U] |
1 |
Weight with packaging [kg(lb)] |
7.96 (17.55) |
Weight without packaging [kg(lb)] |
6.16 (13.58) |
Maximum power consumption [W] |
- Without PoE: 151 W (without cards) - Full PoE load: 1927 W (PoE: 1745 W, without cards) |
Typical power consumption [W] |
118 |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Maximum heat dissipation [BTU/hour] |
- Without PoE: 515.23 (without cards) - Full PoE load: 6575.12 (without cards) |
Typical heat dissipation [BTU/hour] |
402.63 |
Power supply mode |
Pluggable power supply |
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45-65 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: -48 V DC to -60 V DC |
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Number of power slots |
2 |
Number of card slots |
1 |
Memory |
2 GB |
Flash memory |
1 GB in total. To view the available flash memory size, run the display version command. |
Redundant power supply |
1+1 Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. |
Types of fans |
Pluggable |
Noise at normal temperature (acoustic power) [dB(A)] |
Dual-AC 600 W, 70% load: 57.77 dBA Dual-AC 1000 W, 70% load: 63.78 dBA Dual-DC 1000 W, 70% load: 62.38 dBA Dual-AC 600 W, 100% load: 63.78 dBA Dual-AC 1000 W, 100% load: 68.07 dBA Dual-DC 1000 W, 100% load: 66.26 dBA |
Airflow direction |
Air intake from left, front, and right and air exhaust from rear |
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
Short-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Long-term operating temperature [°C(°F)] |
-5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.51 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: - The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year. - The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. - The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year. If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
MTBF [year] |
53.82 |
MTTR [hour] |
2 |
Availability |
> 0.99999 |
Maximum number of physical ports on the entire device |
60 (including cards) |
Maximum number of 100GE ports |
0 |
Maximum number of 40GE ports |
2 (including those on cards) |
Maximum number of 25GE ports |
2 (including cards) |
Maximum number of 10GE ports |
16 (including those on cards) |
Maximum number of GE ports |
60 (including cards) |
Maximum number of FE ports |
52 (including those on cards) |
10GE optical interface |
4 |
USB |
Supported |
Console port |
RJ45 |
Eth Management port |
RJ45 |
Service port surge protection [kV] |
- |
Power supply surge protection |
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode - Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode |
RPS input |
Not supported |
PoE |
Supported |
PoE power supply |
Supported |