Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
![]() |
Description | CE6881-48T6CQ switch (48*10GE RJ45, 6*100GE QSFP28, without fan and power modules) |
Part Number | 02353GLB/02353GLC /02353GLD | |
Model | CE6881-48T6CQ | |
First supported version |
|
![]() |
![]() |
![]() |
![]() |
Dimensions with packaging (H x W x D) [mm (in.)] | 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | - Basic dimensions (the depth excludes the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) - Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.1 mm (1.72 in. x 17.40 in. x 17.56 in.) |
Weight without packaging [kg (lb)] | 6.6 kg (14.6 lb) (excluding optical modules, power modules, and fan modules) |
Weight without packaging (full configuration) [kg (lb)] | 8.9 kg (19.6 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported) |
Weight with packaging [kg (lb)] | 10.4 kg (22.93 lb) |
Weight with packaging (full configuration) [kg (lb)] | 12.3 kg (27.12 lb) |
Chassis height [U] | 1 |
Installation Type | Cabinet Installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 4-core, 1.4 GHZ |
Memory | DRAM: 4 GB |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
USB | Supported |
Power supply mode | AC,DC,HVDC |
Console port | RJ45 |
Downlink Service interface | 48*10GE RJ45 (Only full-duplex is supported) |
Uplink Service interface | 6 x 100GE QSFP28 Note: 1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. 2. In versions earlier than V200R022C00, 100GE ports cannot be split into 4 x 25GE and 4 x 10GE ports. In V200R022C00 and later versions, ports 5 and 6 can be split into 4 x 25GE or 4 x 10GE ports. Other ports cannot be split. 40GE/100GE port 5 supports only static split, and 40GE/100GE port 4 is deleted after split is configured. After split is canceled for 40GE/100GE port 5, 40GE/100GE port 5 can be restored, but 40GE/100GE port 4 can be restored only after the card is restarted. After a port is split, the port cannot be connected using a copper cable. When a copper cable is installed on the port, a message is displayed, indicating that the medium does not match. 3. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on stack ports and M-LAG peer-link ports. 100G 3/5 m copper cables support only RS FEC. After the non-RS FEC mode is configured, the port enters the error-down state. |
Service port supporting the stack function | 10GE electrical ports and 100GE optical ports |
RTC | Supported |
Typical power consumption [W] | - 347 W (50% throughput, 3 m Ethernet cables on 48 ports and QSFP28 high-speed cables on 6 ports, normal temperature, dual power modules) - 362 W (50% throughput, 3 m Ethernet cables on 48 ports and short-distance optical modules on 6 ports, normal temperature, dual power modules) |
Typical heat dissipation [BTU/hour] | - 1184 BTU/hour (50% throughput, 3 m Ethernet cables on 48 ports and QSFP28 high-speed cables on 6 ports, normal temperature, dual power modules) - 1235 BTU/hour (50% throughput, 3 m Ethernet cables on 48 ports and short-distance optical modules on 6 ports, normal temperature, dual power modules) |
Static power consumption [W] | 235 W |
Static heat dissipation [BTU/hour] | 801 BTU/hour |
Maximum power consumption [W] | 452 W |
Maximum heat dissipation [BTU/hour] | 1542 BTU/hour |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | - 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1000 W DC power module: -48 V DC to -60 V DC - 1200 W high-voltage DC power module: 240 V DC to 380 V DC |
Input voltage range [V] | - 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1000 W DC power module: -38.4 V DC to -72 V DC - 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A] | - 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) - 1000 W DC power module: 30 A (-48 V DC to -60 V DC) - 1200 W high-voltage DC power module: 8 A |
Rated output power [W] | - 600 W AC&240 V DC power module: 600 W - 1000 W DC power module: 1000 W - 1200 W high-voltage DC power module: 1200 W |
Certification | - Complies with safety standards. - Complies with EMC standards. - Complies with environmental protection standards. |
Power supply surge protection [kV] | - AC: 6 kV in common mode and 6 kV in differential mode - DC: 4 kV in common mode and 2 kV in differential mode - HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Redundant fans | The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Front-to-back or back-to-front airflow, depending on the selected fan modules and power modules |
Availability | 0.9999953209 |
MTBF [year] | 48.16 years |
MTTR [hour] | 1.78 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | - Front-to-back airflow: 49 dB(A) on average (maximum: 52 dB(A)) - Back-to-front airflow: 50 dB(A) on average (maximum: 52 dB(A)) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | - Front-to-back airflow: 69 dB(A) on average (maximum: 74 dB(A)) - Back-to-front airflow: 67 dB(A) on average (maximum: 73 dB(A)) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | < 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40°C to +70°C (-40°F to +158°F) |
BOM Number
|
License Query
|
Abbreviation
|
Description
|
---|---|---|---|
88060BSM |
Annual fee of the N1 foundation function package on the CE6800 |
N1-CE68CFFD-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88061LHL |
Annual fee of the N1 premium software package of the CE6800 |
N1-CE68CFPM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88038CPK |
Value-added package of specified flow analysis (per 100 VMs) |
N1-CE-LIC-AFP100VM |
Controlled features: The specified flow analysis (per 100 VMs) function |
88032UTX |
VXLAN function of the CE6800 |
CE68-LIC-VXLAN |
Controlled feature: VXLAN function |
88036KVS |
N1 UPG-F-A upgrade package of the CE6800 |
N1-CE68UPG-F-A |
Controlled features: FabricInsight network health, NSH, iMaster NCE-Fabric multi-cloud multi-DC scenario package, FabricInsight multi-cloud multi-DC analysis scenario package, enhanced DAD in a stack, and iMaster NCE-Fabric OPP scenario package functions |
88060QDU |
Annual fee of the CE6800 enhanced function package A |
N1-CE68ADA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060QDV |
Annual fee of the CE6800 enhanced function package B |
N1-CE68ADB-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88038CPK |
Annual fee of the Value-added package of specified flow analysis (per 100 VMs) |
N1-CEAFP100VM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88061LHX |
Annual fee of the N1 UPG-A-P upgrade package of the CE6800 |
N1-CE68UGAP-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060MWK |
Annual fee of the security function package of the CE6800 |
N1-CE68SEC-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
![]() |
Packing: 1. Original Carton Package. 2. As your requirement. |
![]() |
Delivery: 1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software.
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.