Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
![]() |
Description | CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, Without Fan and Power Modules) |
Part Number | 02355KTL 02355KTK 02355KTL |
|
Model | CE6855-48XS8CQ | |
First supported version |
|
![]() |
![]() |
![]() |
![]() |
Dimensions with packaging (H x W x D) [mm (in.)] | 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | - Basic dimensions (the depth excludes the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) - Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.5 mm (1.72 in. x 17.40 in. x 17.58 in.) |
Weight without packaging [kg (lb)] | 6.36 kg (14.02 lb) (excluding optical modules, power modules, and fan modules) |
Weight without packaging (full configuration) [kg (lb)] | 8.35 kg (18.41 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported) |
Weight with packaging [kg (lb)] | 10.63 kg (23.43 lb) |
Weight with packaging (full configuration) [kg (lb)] | 12.62 kg (27.82 lb) |
Chassis height [U] | 1 |
Installation Type | Cabinet installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 4-core, 1.4 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
SSD Flash | 4GB SSD |
USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Power supply mode | AC,DC,HVDC |
Console port | RJ45 |
Downlink Service interface | 48*10GE SFP+ |
Uplink Service interface | 8 x 100GE QSFP28 |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] | 138 W (100% traffic load, copper cables on 24 x 10GE + 4 x 100GE ports, normal temperature, dual AC power modules) 156 W (100% traffic load, short-distance optical modules on 24 x 10GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] | - 471 BTU/hour (100% traffic load, copper cables on 24 x 10GE + 4 x 100GE ports, normal temperature, dual AC power modules) - 532 BTU/hour (100% traffic load, short-distance optical modules on 24 x 10GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 124 W |
Static heat dissipation [BTU/hour] | 423 BTU/hour |
Maximum power consumption [W] | 187 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 298 W (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) |
Maximum heat dissipation [BTU/hour] | - 638 BTU/hour (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) - 1017 BTU/hour (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | - 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1200 W DC power module: -48 V DC to -60 V DC; +48 V DC |
Input voltage range [V] | - 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1200 W DC power module: -38.4 V DC to -72 V DC; +40 V DC to +57 V DC |
Maximum input current [A] | - 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) - 1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC) |
Rated output power [W] | - 600 W AC&240 V DC power module: 600 W - 1200 W DC power module: 1200 W |
Certification | - Compliance with safety standards - Compliance with EMC standards - Compliance with environment and environmental protection standards |
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 3 |
Redundant fans | The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Availability | 0.9999948505 |
MTBF [year] | 44.34 years |
MTTR [hour] | 2 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: 50.1 dB(A) on average; maximum: 55.9 dB(A) Back-to-front airflow: 48.4 dB(A) on average; maximum: 56.1 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: 66.4 dB(A) on average; maximum: 73.2 dB(A) Back-to-front airflow: 67.3 dB(A) on average; maximum: 72.5 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Item | CloudEngine 6855-48XS8CQ |
Device virtualization | M-LAG |
Interface | Jumbo frames |
Network virtualization | VXLAN routing and VXLAN bridging |
BGP-EVPN | |
SDN | iMaster NCE-Fabric |
Network convergence | PFC and AI ECN |
RDMA and RoCE (RoCE v1 and RoCE v2) | |
Programmability | OpenFlow |
OPS programming | |
Traffic analysis | NetStream |
VLAN | Access, trunk, and hybrid ports |
Default VLAN | |
MAC address table | Automatic MAC address learning and aging |
Static, dynamic, and blackhole MAC address entries | |
Source MAC address filtering | |
MAC address learning limiting based on ports and VLANs | |
IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP |
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
IPv6 | VXLAN over IPv6 |
IPv6 VXLAN over IPv4 | |
IPv6 neighbor discovery (ND) | |
Path MTU discovery (PMTU) | |
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | |
Multicast | Multicast routing protocols such as IGMP, PIM-SM, and MSDP |
IGMP snooping and IGMP proxy | |
IPv6 Layer 3 multicast and configuration of both Layer 2 and Layer 3 multicast services | |
Fast leave of multicast member interfaces | |
Multicast traffic suppression | |
Reliability | LACP |
STP, RSTP, VBST, and MSTP | |
BPDU protection | |
Smart link and multi-instance | |
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms | |
VRRP, VRRP load balancing, and BFD for VRRP | |
BFD for BGP, IS-IS, OSPF, and static routing | |
BFD for VXLAN | |
Traffic classification based on Layer 2 headers, Layer 3 protocols, and Layer 4 protocol priorities | |
QoS | ACL, CAR, re-marking, and scheduling |
Queue scheduling modes such as PQ, DRR, and PQ+DRR | |
Congestion avoidance mechanisms such as WRED and tail drop | |
Traffic shaping | |
IEEE 1588v2 | |
Intelligent O&M | Network-wide path detection |
Telemetry | |
Enhanced ERSPAN | |
IFIT | |
Packet Event: packet loss visualization and ultra-long latency visualization | |
Statistics collection on the buffer microburst status | |
VXLAN OAM: VXLAN ping and VXLAN tracert | |
Intelligent lossless network | PFC deadlock prevention |
AI ECN | |
ECN Overlay | |
Enhanced NSLB | |
Configuration and maintenance | Terminal login through the console port, Telnet, and SSH |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
Hot patches | |
User operation logs | |
Configuration rollback | |
ZTP | |
Security and management | MACsec |
Microsegmentation | |
Command line authority control based on user levels, preventing unauthorized users from using commands | |
Defense against DoS, ARP, and ICMP attacks | |
Port isolation, port security, and sticky MAC | |
Binding of the IP address, MAC address, port ID, and VLAN ID | |
Authentication methods, including AAA, LDAP, RADIUS, and HWTACACS | |
RMON |
BOM Number
|
License Query
|
Abbreviation
|
Description
|
---|---|---|---|
88036QEJ |
CE6800 RDMA application acceleration function package 2 |
N1-CE68LIC-AFRD-2 |
Controlled features: The AI ECN, iQCN, and TCP FlexBuffer (TCP acceleration) functions |
88061HBY |
Annual fee of the packet loss and latency visualization function package of the CE6800 |
N1-CE68PLLV-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88036RYH |
N1 UPG-A-P upgrade package of the CE6800 |
N1-CE68UPG-A-P |
Controlled features: The iMaster NCE-Fabric intent standard package, FabricInsight network traffic analysis, AnyFlow, packet loss and latency visualization, iMaster NCE-Fabric digital map standard package, iMaster NCE-Fabric per virtual network system - digital map scenario package, and FabricInsight IFIT service assurance functions |
88038QKJ |
AI Fabric HPC scenario value-added package of the CE6800 |
N1-CE68LIC-HPC |
Controlled features: The AI ECN, iQCN, TCP FlexBuffer (TCP acceleration), and Rail Group functions |
88060BSM |
Annual fee of the N1 foundation function package on the CE6800 |
N1-CE68CFFD-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88035UQQ |
CE6800 enhanced function package A |
N1-CE68LIC-ADA |
Controlled features: The telemetry, IOAM, and 1588v2 (PTP) functions |
88060QCW |
Annual fee of the N1 management function package on the CE6800 |
N1-CE68CFMM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037RHY |
CE6800 IFIT function |
CE68-LIC-IFIT |
Controlled features: IFIT function |
88060QBY |
Annual fee of the NE router management by iMaster NCE-Fabric |
N1-CEFCFGW-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88037NPK |
CE6800 cloud data center network software package |
CDCN-LIC-68-FD |
Controlled features: CE6800 management through iMaster NCE-Fabric, FabricInsight network intelligent basic analysis, PNF basic software, telemetry, IOAM, 1588v2 (PTP), VXLAN, M-LAG upgrade in maintenance mode, and virtual peering M-LAG functions |
88061EFH |
Annual fee of the N1 UPG-F-A upgrade package of the CE6800 |
N1-CE68UGFA-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88061LHX |
Annual fee of the N1 UPG-A-P upgrade package of the CE6800 |
N1-CE68UGAP-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88060BSR |
Annual fee of the AI fabric function package on the CE6800 |
N1-CE68AIF-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88039ANW |
CE6800 enhanced package for the centralized storage scenarios |
N1-CE68LIC-NOF-ENHANCED |
Controlled features: The basic software, telemetry, FabricInsight network intelligent basic analysis, AI ECN, iQCN, iNOF, service telemetry, M-LAG upgrade in maintenance mode, NPCC, antilocking PFC (ABS PFC), FabricInsight network health, FabricInsight IFIT-based service assurance, and IFIT functions |
88038CPK |
Annual fee of the Value-added package of specified flow analysis (per 1000 VMs) |
N1-CEAFP1KVM-SnS1Y |
The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required. |
88036TQN |
CE6800 M-LAG upgrade in maintenance mode |
CE68-LIC-LU |
Controlled feature: M-LAG upgrade in maintenance mode function |
88035UPQ |
N1 management function package of the CE6800 |
N1-CE68LIC-CFMM |
Controlled features: The basic software, VXLAN, M-LAG upgrade in maintenance mode, and virtual peering M-LAG functions |
88035PVD |
Security function package of the CE6800 |
N1-CE68LIC-SEC |
Controlled features: MACsec function |
88036KVS |
N1 UPG-F-A upgrade package of the CE6800 |
N1-CE68UPG-F-A |
Controlled features: The FabricInsight network health, multicast NAT, iMaster NCE-Fabric OPP scenario package, IFIT, iMaster NCE-Fabric multi-cloud and multi-DC scenario package, FabricInsight multi-cloud and multi-DC analysis scenario package, TCP FlexBuffer (TCP acceleration), PIM FRR (MoFRR), and DPFR functions |
88034VUP |
1588v2 (PTP) function of the CE6800 |
CE68-LIC-PTP |
Controlled feature: 1588v2 (PTP) function |
Device Description | |
CE6855-48XS8CQ | CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, Without Fan and Power Modules) |
CE6855-48XS8CQ-B | CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, 2*AC Power Modules, 4*Fans, Portside Intake) |
CE6855-48XS8CQ-F | CE6855-48XS8CQ switch (48*10GE SFP+, 8*100GE QSFP28, 2*AC Power Modules, 4*Fans, Portside Exhaust) |
Fan module | |
Model | Description |
FAN-031A-F | Fan box (F,FAN panel side intake) |
FAN-031A-B | Fan box (B,FAN panel side exhaust) |
FAN-031B-F | Fan box (F,FAN panel side intake), supporting the electronic label function |
FAN-031B-B | Fan box (B,FAN panel side exhaust), supporting the electronic label function |
Power module | |
Model | Description |
PAC600S12-PF | 600W AC Power Module (Front to Back, Power panel side intake) |
PAC600S12-PB | 600W AC Power Module (Back to Front, Power panel side exhaust) |
PDC1K2S12-PB | 1200W DC Power Module (Front to Back, Power panel side intake) |
PDC1K2S12-CE | 1200W DC Power Module (Back to Front, Power panel side exhaust) |
Software | |
N1-CE68LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 6800 |
N1-CE68CFFD- SnS1Y | N1-CloudFabric Foundation SW License for CloudEngine 6800-SnS-Year |
N1-CE68LIC-CFAD | N1-CloudFabric Advanced SW License for CloudEngine 6800 |
N1-CE68CFAD- SnS1Y | N1-CloudFabric Advanced SW License for CloudEngine 6800-SnS-Year |
N1-CE68LIC-CFPM | N1-CloudFabric Premium SW License for CloudEngine 6800 |
N1-CE68CFPM- SnS1Y | N1-CloudFabric Premium SW License for CloudEngine 6800-SnS-Year |
N1-CE68UPG-F-A | N1-CloudEngine 6800 Upgrade SW License:Foundation to Advanced |
N1-CE68UGFA- SnS1Y | N1-CloudEngine 6800 Upgrade SW License:Foundation to Advanced-SnS-Year |
N1-CE68UPG-A-P | N1-CloudEngine 6800 Upgrade SW License:Advanced to Premium |
N1-CE68UGAP- SnS1Y | N1-CloudEngine 6800 Upgrade SW License:Advanced to Premium-SnS-Year |
N1-CE68LIC-AFRD-2 | N1-CloudEngine 6800 AI Fabric RDMA Application Acceleration Function 2 |
N1-CE68AFRD2- SnS1Y | N1-CloudEngine 6800 AI Fabric RDMA Application Acceleration Function 2-SnS-Year |
N1-CE68LIC-SEC | N1-CloudEngine 6800 Security Function |
N1-CE68SEC-SnS1Y | N1-CloudEngine 6800 Security Function-SnS-Year |
N1-CE-F-LIC-MDCA | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed |
N1-CEFMDCA - SnS1Y | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed device-SnS-Year |
N1-CE-F-LIC-DM | N1-CloudEngine Digital Map Basic Function-Fixed |
N1-CEFDM-SnS1Y | N1-CloudEngine Digital Map Function |
N1-CE-LIC-AFP100VM | N1-CloudEngine Specified Flow Analysis Value-added Package Per 100 VM |
N1-CEAFP100VM-SnS1Y | N1-CloudEngine Specified Flow Analysis Value-added Package Per 100 VM-SnS-Year |
![]() |
Packing: 1. Original Carton Package. 2. As your requirement. |
![]() |
Delivery: 1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software
After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.
![]() |
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu. |
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, Z TE, H 3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours. |
![]() |
![]() |
![]() |
![]() |
![]() |
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.