| Customization: | Available |
|---|---|
| Type: | Enterprise Switch |
| Condition: | Original and New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Series | Modle | |
S5730S-EI | S5730S-68C-PWR-EI | V200R011C10 and later versions |




Item | Description |
Memory (RAM) | 1 GB |
Flash | 240 MB |
Mean time between failures (MTBF) | 43.28 years |
Mean time to repair (MTTR) | 2 hours |
Availability | > 0.99999 |
Service port surge protection | Common mode: ±7 kV |
Power supply surge protection | Using 500 W AC power modules: ±6 kV in differential mode, ±6 kV in common modeUsing 650 W DC or 1150 W AC power modules: ±2 kV in differential mode, ±4 kV in common mode |
Dimensions (W x D x H) | 442.0 mm x 420.0 mm x 44.4 mm (17.4 in. x 16.5 in. x 1.74 in.) |
Weight (including packaging materials) | 8 kg (17.64 lb) |
Stack ports | Any 10GE SFP+ or 40GE QSFP+ ports |
RTC | Supported |
RPS | Not supported |
PoE | Supported |
Rated voltage range | 100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range | 90 V AC to 264 V AC, 47 Hz to 63 Hz -38.4 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) | Using 650 W DC power modules or 500 W AC power modulesNot providing the PoE function: 68.3 W (without card)100% PoE loads: 925 W (system power consumption: 185.8 W, PoE: 739.2 W, without card)Using 1150 W AC power modulesNot providing the PoE function: 68.3 W (without card)100% PoE loads: 1733 W (system power consumption: 293 W, PoE: 1440 W, without card) |
Typical power consumption (30% of traffic load)Tested according to ATIS standardEEE enabledNo PoE power consumption | 50.1 W (without card) |
Operating temperature | 0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The operating temperature of the switch is 0°C to 40°C (32°F to 104°F) when it uses QSFP+ optical modules with 10 km or longer transmission distances. |
Short-term operating temperature | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year. |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) | < 64.3 dBA |
Relative humidity | 5% to 95%, noncondensing |
Operating altitude | 0-5000 m (0-16404 ft.) |
Certification | EMC certificationSafety certificationManufacturing certification |
Part number | 98010793 |