02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)

Product Details
Customization: Available
Communication Mode: Full-Duplex & Half-Duplex
Type: Ethernet Switch
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (16)
  • 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
  • 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
  • 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
  • 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
  • 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
  • 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Ordering Information
  • Packaging & Shipping
  • Installation and service
  • Company Information
  • FAQ
Overview

Basic Info.

Model NO.
CE8850-32CQ-EI
Ports
≧48
Forwarding Performance
1620mpps
Switching Capacity
2.56t/25.6t
Uplink Ports
2*10ge SFP+
Downlink Ports
32*40ge/100ge Qsfp28
Redundant Power Supply
1+1 Backup
Chassis Height [U]
1u
Rtc
Supported
Power Supply Mode
AC
Number of Power Modules
2
Number of Fans
2
Vlan
Access,Trunk,and Hybrid Ports
Vxlan
Not Supported
Poe
Not Supported
Transport Package
Mail Box Packing
Specification
6.2kg
Trademark
HW
Origin
China
Production Capacity
500 Piece/Pieces Per Month

Packaging & Delivery

Package Size
42.00cm * 44.20cm * 4.36cm
Package Gross Weight
6.200kg

Product Description

Product Description
CloudEngine CE8850-32CQ-EI brings a combination of both high performance and low latency to cloud-oriented data center networks and high-end campus networks alike. Additionally, the series supports an extensive range of data center features, Software-Defined Networking (SDN) capabilities, and high performance stacking technologies. With 10, 25, 40, 100, 200, and 400 GE ports, as well as flexible plug-in cards.
02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+) Part Number 02350SBD
02350SBC
02350SQW
Model CE8850-32CQ-EI
Description (CE8850-32CQ-EI Switch(32-Port 100GE QSFP28,2-Port 10GE SFP+,2*AC Power Module,2*FAN Box,Port-side Intake))
02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+) 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+) 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
Product Parameters

Hardware specifications
 
Other part numbers 02350SBC (CE8850-32CQ-EI Switch(32-Port 100GE QSFP28,2-Port 10GE SFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust))
02350SBD(CE8850-32CQ-EI Switch(32-Port 100GE QSFP28,2-Port 10GE SFP+,2*AC Power Module,2*FAN Box,Port-side Intake))
Installation Type Cabinet Installation
Depth [mm] 420 mm
Chassis height [U] 1
Wide [mm] 442 mm
Height [mm] 43.6 mm
Weight without packaging [kg(lb)] 6.2 kg (13.67 lb)
Maximum power consumption [W] 453 W
Typical power consumption [W] 219 W (100% throughput, SFP+ cables on 2 ports and QSFP28 cables on 32 ports, double power modules)
Static power consumption [W] 169 W
Heat dissipation mode Air cooling
Maximum heat dissipation [BTU/hour] 1544 BTU/hour
Typical heat dissipation [BTU/hour] 748 BTU/hour (100% throughput, SFP+ cables on 2 ports and QSFP28 cables on 32 ports, double power modules)
Static heat dissipation [BTU/hour] 575 BTU/hour
Power supply mode AC
Rated input voltage [V] AC input, rated voltage range: 100 V AC to 240 V AC; 50/60 Hz DC input, rated voltage range: -48 V DC to -60 V DC
Input voltage range [V] AC input, maximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz DC input, maximum voltage range: -38.4 V DC to -72 V DC
Maximum input current [A] 600 W AC power module: 100 V to 240 V, 9 A -48 V DC 600 W module: -48 V to -60 V, 20 A
Rated output power [W] - 600 W AC power module: 600 W - 600 W DC power module: 600 W
Maximum output power [W] AC: 600 W -48V DC: 600 W
Memory DRAM: 4 GB
NOR Flash 32MB
NAND Flash 1GB
USB Supported
Console port RJ45
Downlink Service interface 32*40GE/100GE QSFP28
Uplink Service interface 2 x 10GE SFP+
Service port supporting the stack function 10GE and 100GE optical ports
RTC Supported
Switching capacity [bps,bit/s] To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
Redundant fans 1+1 backup not supported
Redundant power supply 1+1 backup
Number of power modules 2
Power supply surge protection AC: 6 kV in common mode and 6 kV in differential mode
Types of fans Pluggable
Number of fans 2
Airflow direction port-side intake/port-side exhaust airflow
Storage temperature [°C(°F)] -40ºC to +70ºC (-40°F to +158°F)
Long-term operating temperature [°C(°F)] 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Storage relative humidity [RH] 5% to 95% RH, non-condensing
Long-term operating relative humidity [RH] 5% RH to 95% RH, noncondensing
Storage altitude [m(ft.)] < 5000 m (16404 ft.)
Long-term operating altitude [m(ft.)] < 5000 m (16404 ft.)
MTBF [year] 44.34 years
MTTR [hour] 1.68 hours
Noise at high temperature (40°C, sound pressure) Front-to-back airflow: 70 dBA in average (maximum: 75 dBA) Back-to-front airflow: 67 dBA in average (maximum: 73 dBA)
Noise at normal temperature (27°C, sound pressure) Back-to-front airflow: < 52 dB(A) Front-to-back airflow: < 52 dB(A)
Availability 0.99999576496
Product specifications
 
Item  CloudEngine 8850-32CQ-EI 
Device virtualization Intelligent stack (iStack)
M-LAG
Data center interconnect (DCI) VXLAN mapping, enabling Layer 2 interconnection between DCs
Network virtualization VXLAN routing and VXLAN bridging
BGP-EVPN
TRILL (supported only by the CloudEngine 8850-64CQ-EI)
QinQ access VXLAN
SDN iMaster NCE-Fabric
Network convergence Fibre Channel over Ethernet (FCoE)
Data Center Bridging Exchange Protocol (DCBX), Priority-based Flow Control (PFC), and expanded trunking system (ETS)
Remote direct memory access (RDMA) and RoCE (RoCEv1 and RoCEv2)
Programmability OPS programming
Ansible-based automatic configuration and open-source module release
Traffic analysis NetStream
sFlow
VLAN Access, trunk, and hybrid ports
Default VLAN
QinQ
MUX VLAN
GARP VLAN Registration Protocol (GVRP)
MAC address entry Automatic MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Source MAC address filtering
MAC address learning limiting by port and VLAN ID
IP routing IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+
IPv6 IPv6 VXLAN over IPv4
VXLAN over IPv6 (supported only by the CE8850E-32CQ-EI)
IPv6 neighbor discovery (ND)
Path MTU Discovery (PMTU)
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6
Multicast Multicast routing protocols, such as the Internet Group Multicast Protocol (IGMP), Protocol Independent
Multicast-Sparse Mode (PIM-SM), Protocol Independent Multicast-Dense Mode (PIM-DM), Multicast Source Discovery Protocol (MSDP), and Multicast BGP (MBGP)
IGMP snooping
IGMP proxy
Fast leaving of multicast member interfaces
Multicast traffic suppression
Multicast VLAN
Multicast VXLAN
MPLS Basic MPLS
Reliability Link Aggregation Control Protocol (LACP)
STP, RSTP, VBST, and MSTP
BPDU protection, root protection, and loop prevention
Smart Link and multi-instance
Device Link Detection Protocol (DLDP)
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms
G.8032 Ethernet Ring Protection Switching (ERPS)
VRRP, VRRP load sharing, and BFD for VRRP
BFD for BGP, IS-IS, OSPF, and static routing
BFD for VXLAN
QoS Traffic classification based on Layer 2 protocol headers, Layer 3 protocol headers, and Layer 4 protocol priorities
ACL, CAR, re-marking, and scheduling
Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR
Congestion avoidance mechanisms such as WRED and tail drop
Traffic shaping
Intelligent O&M Network-wide path detection
1588v2 (supported only by the CloudEngine 8850-64CQ-EI)
Telemetry
INT (IOAM) and enhanced ERSPAN
Intelligent traffic analysis
RoCE traffic visualization: RoCE traffic KPI analysis
Statistics collection on the buffer microburst status
VXLAN OAM: VXLAN ping and VXLAN tracert
Intelligent lossless network  PFC deadlock prevention
AI ECN: The switch intelligently adjusts the ECN thresholds of lossless queues based on the live-network traffic model.
Fast CNP: The switch directly sends CNP packets to server NICs at the source end to shorten the CNP feedback path.
DLB
ECN overlay
INC (supported only by the CE8850-64CQ-EI)
Configuration and maintenance Terminal login through the console port, Telnet, and SSH
Network management protocols, such as SNMPv1/v2/v3
File upload and download through FTP and TFTP
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade
802.3az Energy Efficient Ethernet (EEE)


License
 
BOM Number
License Query
Abbreviation
Description
88036RYF N1 UPG-A-P upgrade package of the CE8800 N1-CE88UPG-A-P Controlled features: The iMaster NCE-Fabric intent standard package, FabricInsight network flow analysis, IFIT, iMaster NCE-Fabric digital map standard package, iMaster NCE-Fabric per virtual network system - digital map scenario package, and FabricInsight IFIT service assurance functions
When the license is not activated, these controlled features do not take effect and cannot be configured.
One switch requires only one license.
88036KVQ N1 UPG-F-A upgrade package of the CE8800 N1-CE88UPG-F-A Controlled features: FabricInsight network health, iMaster NCE-Fabric multi-cloud multi-DC scenario package, FabricInsight multi-cloud multi-DC analysis scenario package, enhanced DAD in a stack, and iMaster NCE-Fabric OPP scenario package functions
When the license is not activated, these controlled features do not take effect and cannot be configured.
One switch requires only one license.
88061EFF Annual fee of the N1 UPG-F-A upgrade package of the CE8800 N1-CE88UGFA-SnS1Y The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required.
88038CPK Value-added package of specified flow analysis (per 100 VMs) N1-CE-LIC-AFP100VM Controlled features: The specified flow analysis (per 100 VMs) function
When the license is not activated, the function does not take effect and cannot be configured.
88037RGT CE8800 IFIT function CE88-LIC-IFIT Controlled features: IFIT function
When the license is not activated, the controlled feature does not take effect and cannot be configured.
One switch requires only one license.
88033DNJ FCF for all ports of the CE8800 CE88-LIC-FCFAL Controlled feature: FCF function
When the license is not activated, the FCF function does not take effect and cannot be configured.
One switch requires only one license that allows you to configure the FCF function on all ports.
88035TFC N1 FabricInsight network intelligent basic analysis of the CE8800 N1-CE-F-LIC-FIF Controlled features: FabricInsight network intelligent basic analysis and Telemetry functions
When the license is not activated, these controlled features do not take effect and cannot be configured.
One switch requires only one license.
88038CPK Annual fee of the Value-added package of specified flow analysis (per 100 VMs) N1-CEAFP100VM-SnS1Y The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required.
88035DWP N1 foundation function package of the CE8800 N1-CE88LIC-CFFD Controlled features: CE8800 management by iMaster NCE-Fabric, the FabricInsight network intelligent basic analysis, basic software , Telemetry, discarded packet capture, IOAM, 1588v2 (PTP), VXLAN functions
When the license is not activated, these controlled features do not take effect and cannot be configured.
One switch requires only one license.
88060QDN Annual fee of the enhanced function package A of the CE8800 N1-CE88ADA-SnS1Y The upgrade, maintenance, and migration services are subject to the validity period of the purchased license. After the annual fee expires, the license function package still takes effect, but the upgrade, maintenance, and migration services become unavailable. You are advised to renew the annual fee as required.
Ordering Information
Active Device   
CE8850-EI-F-B0B CE8850-32CQ-EI Switch(32*100GE QSFP28,2*10GE SFP+,2*AC Power Module,Port-side Exhaust)
CE8850-EI-B-B0B CE8850-32CQ-EI Switch(32*100GE QSFP28,2*10GE SFP+,2*AC Power Module,Port-side Intake)
CE8850-32CQ-EI CE8850-32CQ-EI Switch(32*100GE QSFP28,2*10GE SFP+,Without Fan and Power Module)
Fan module   
Model  Description 
FAN-40HA-F Fan box (HA,Front to Back,FAN panel side intake)
FAN-40HA-B Fan box (HA,Back to Front,FAN panel side exhaust)
Power module   
Model  Description 
PAC-600WA-B 600W AC Power Module (Back to Front, Power panel side  exhaust)
PAC-600WA-F 600W AC Power Module (Front to Back, Power panel side intake)
Software  
CE88-LIC-BUN01 CE8800 Function License Bundle 1
CE88-LIC-TLM CE8800 Telemetry Function
CE88-LIC-PTP CE8800 PTP Function (supported only by the CE8850-64CQ-EI)
CE88-LIC-AIF CloudEngine 8800 AI Fabric Function
N1-CE88LIC-CFFD N1-CloudFabric Foundation SW License for CloudEngine 8800
N1-CE88CFFD-SnS1Y N1-CE8800 CloudFabric Foundation Software Package-Subscription and Support-Year
N1-CE88LIC-CFAD N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year
Active Device   
N1-CE88CFAD-SnS1Y N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year
N1-CE88LIC-CFPM N1- CloudEngine 8800 CloudFabric Premium Software Package
N1-CE88CFPM-SnS1Y N1- CloudEngine 8800 CloudFabric Premium Software Package-Subscription and Support-Year
N1-CE88LIC-AIF N1-CloudEngine 8800 AI Fabric Function
N1-CE88AIF-SnS1Y N1-CE8800 AI Fabric Function-Subscription and Support-Year
N1-CE88LIC-HPC N1-CloudEngine 8800 AI Fabric HPC Scenario Value-added Package
N1-CE88HPC-SnS1Y N1-CloudEngine 8800 AI Fabric HPC Storage Scenario Value-added Package-Subscription and
Support-Year
N1-CE-F-LIC-MDCA N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed
N1-CEFMDCA -SnS1Y N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed DeviceSubscription and Support-Year
N1-CE88UPG-F-A N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced
N1-CE88UGFA-SnS1Y N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced- Subscription and Support-Year
N1-CE88UPG-A-P N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium
N1-CE88UGAP-SnS1Y N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium-Subscription and Support-Year

Packaging & Shipping

 

02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)

Packing:

 1. Original Carton Package.

 2. As your requirement.

02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)

Delivery:

 1. 3-7 Working days after received the payment.

 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )


 

Installation and service

Installation Instructions:

1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software

After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.

Company Information
02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+) Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu.

 

 

Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, Z TE, H 3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours.
02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)


 

02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+) 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+) 02350sbd CE8850-32cq-Ei Network Switch (32-Port 40GE/100GE QSFP, 2-Port 10GE SFP+)
FAQ

1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.

2. Can I buy samples placing orders?
Yes. Please feel free to contact us.

3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.

4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.

5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.

6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now