| Customization: | Available |
|---|---|
| Type: | Wired |
| Network Site: | Intermediate Node Routers |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 02355VGU |
Model | AR6710-H4T4X2Y7 |
Description | AR6710-H4T4X2Y7 assembly chassis |
First supported version | V600R023C10 |




Technical Specifications | |
Installation type | Rack |
Height[mm] | 43.6 mm |
Depth[mm] | 420.0 mm |
Wide[mm] | 442.0 mm |
Chassis height[U] | 1 |
Weight with packaging[kg] | 11.26 kg (24.82 lb) |
Weight without packaging[kg] | 5.8 (12.79) |
Number of service board slots | 7 |
XSIC slots (default/maximum) | 0/2 |
WSIC slots (default/maximum) | 1/4 |
SIC slots (default/maximum) | 6/6 |
MIC slots (default/maximum) | 0/0 |
Per-slot bandwidth | Slot 1: The maximum bandwidth is 1 Gbit/s. Slot 2: The maximum bandwidth is 10 Gbit/s. Slot 3: The maximum bandwidth is 1 Gbit/s. Slot 4: The maximum bandwidth is 10 Gbit/s. Slot 6: The maximum bandwidth is 10 Gbit/s. Slot 7: The maximum bandwidth is 1 Gbit/s. Slot 8: The maximum bandwidth is 10 Gbit/s. |
Redundant power supply | - Double AC power modules (1+1 backup) - Double DC power modules (1+1 backup) |
Redundant MPUs | Supported |
RPS input | Not supported |
PoE | Not supported |
IP rating | IP20 |
MTBF[year] | 177.04 |
MTTR[h] | 2 |
Availability | 0.999998710 |
Maximum power consumption[W] | 25.2 |
Typical power consumption[W] | 12.6 |
Power supply mode | AC/HVDC pluggable, DC pluggable |
Number of power modules | 2 |
Input voltage range[V] | Maximum AC input voltage: 90 V to 264 V, 47 Hz to 63 Hz Maximum DC input voltage: –38.4 V DC to –72 V DC |
Rated input voltage[V] | Rated AC input voltage: 100 V to 240 V, 50 Hz or 60 Hz Rated DC input voltage: –48 V DC to –60 V DC |
Maximum input current[A] | 5 |
Maximum output power | AC: 300 W DC: 260 W |
Types of fans | Pluggable |
Number of fan modules | 2 |
Heat dissipation mode | Air cooling |
Airflow | Left-to-right airflow |
Noise at normal temperature (acoustic power) | 54.3 |
Storage temperature[°C] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature[°C] | 0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Long-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude[m] | < 5000 m (16404.2 ft.) |
Overtemperature alarm | Supported |
Environmental standards compliance | RoHS REACH WEEE |
Safety regulation certification | IEC 60950-1 IEC 62368-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950-1 GB 4943.1 |
EMC certification | GB/T 9254 EN 55032 EN 55035 CISPR 32 CISPR 35 EN IEC 61000-3-2 EN IEC 61000-3-3 EN50121-1 EN50121-4 FCC CFR Title 47, Part 15, Subpart B ANSI C63.4 ETSI EN 301 489-1 ETSI EN 301 489-52 ETSI EN 300 386 ICES-003 Issue 7 ETSI EN 301 489-3 ETSI EN 301 489-17 |