| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 98010932 |
Model | CloudEngine S5735S-S32ST4X-A |
Description | S5735S-S32ST4X-A bundle (24*GE SFP ports, 8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 1 AC power module) |




Technical Specifications | |
Chassis material | Metal |
Height[mm] | 43.6 mm |
Depth[mm] | 420.0 mm |
Wide[mm] | 442.0 mm |
Chassis height[U] | 1 |
Weight with packaging[kg(lb)] | 8.15 |
Maximum power consumption[W] | 66 |
Typical power consumption[W] | 47 |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Maximum heat dissipation[BTU/hour] | 225.2 |
Typical heat dissipation[BTU/hour] | 160.37 |
Power supply mode | Pluggable power supply |
Input voltage range[V] | - AC input: 90 V AC to 264 V AC; 47 Hz to 63 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC |
Rated input voltage[V] | - AC input: 100 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: –48 V DC to –60 V DC |
Maximum input current[A] | The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications. |
Number of power slots | 2 |
Number of card slots | 0 |
Memory | 1 GB |
Flash memory | 512 MB in total. To view the available flash memory size, run the display version command. |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. |
Types of fans | Built-in |
Noise at normal temperature (acoustic power)[dB(A)] | 59.3 |
Noise at normal temperature (acoustic pressure)[dB(A)] | 44.2 |
Airflow direction | Air intake from left,front and right, air exhaustion from behind |
Storage temperature[°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Short-term operating temperature[°C(°F)] | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) |
Long-term operating temperature[°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate[°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: - The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year. - The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. |
Long-term operating relative humidity[RH] | 5% to 95%, noncondensing |
Storage altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
MTBF[year] | 68.59 |
MTTR[hour] | 2 |
Availability | > 0.99999 |
Maximum number of physical ports on the entire device | 36 |
Maximum number of 100GE ports | 0 |
Maximum number of 40GE ports | 0 |
Maximum number of 25GE ports | 0 |
Maximum number of 10GE ports | 4 |
Maximum number of GE ports | 36 |
Maximum number of FE ports | 32 |
10GE optical interface | 4 |
1000M optical interface | 24 |
1000M electrical interface | 8 |
USB | Supported |
Console port | RJ45 |
Eth Management port | RJ45 |
Service port surge protection[kV] | Common mode: ±7 kV |
Power supply surge protection | - AC power module configured: ±6 kV in differential mode, ±6 kV in common mode - DC power module configured: ±2 kV in differential mode, ±4 kV in common mode |