Description | CE9865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules) |
Part Number | 02356BCE/02356BCF/02356BCJ/02356HYJ | |
Model | CE9865-4C | |
First supported version | V200R020C00 |
![]() |
![]() |
![]() |
![]() |
Hardware specifications
Dimensions with packaging (H x W x D) [mm (in.)] | 370 mm x 635 mm x 1025 mm (14.57 in. x 25.00 in. x 40.35 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | - Basic dimensions (the depth excludes the parts protruding from the body): 175 mm x 442 mm x 765 mm (6.89 in. x 17.40 in. x 30.12 in.) - Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 175 mm x 442 mm x 809.3 mm (6.89 in. x 17.40 in. x 31.86 in.) |
Weight without packaging [kg (lb)] | 26.0 kg (57.32 lb) |
Weight without packaging (full configuration) [kg (lb)] | 35.5 kg (78.26 lb) (with four power modules and five fan modules) |
Weight with packaging [kg (lb)] | 51.0 kg (112.43 lb) |
Weight with packaging (full configuration) [kg (lb)] | 60.5 kg (133.38 lb) (with four power modules and five fan modules) |
Chassis height [U] | 4 |
Installation Type | Cabinet Installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 4-core, 2.2 GHz |
Memory | DRAM: 16 GB |
NOR Flash | 32 MB x 2 |
SSD Flash | 64 GB |
USB | Supported |
Power supply mode | AC,DC,HVDC |
Console port | RJ45 |
Downlink Service interface | The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards: CE98-D32CQ: 32 x 100GE QSFP28 (100GE ports can be used as 40GE ports and cannot be split into 4 x 25GE and 4 x 10GE ports.) CE98-D8DQ: 8 x 400GE QSFP-DD (In V200R021C00, such ports can only work at 400 Gbit/s, cannot be used as 200GE, 100GE, or 40GE ports, and cannot be split. Specifically, they do not support the following split modes: 4 x 100GE, 2 x 200GE, 2 x 100GE, 2 x 40GE, 8 x 50GE, 8 x 25GE, 8 x 10GE, 4 x 50GE, 4 x 25GE, and 4 x 10GE. Auto-negotiation of 400GE copper cables is not supported and such cables can be used only for peer-link. In V200R021C10, such a 400GE port can be dynamically split into 2 x 200GE ports. Currently, only 2 x 200GE 5 m AOCs and 2.5 m copper cables are supported. By default, negotiation is disabled and cannot be enabled for copper cables. If an unsupported module is inserted into such a port, the system displays a message indicating a medium mismatch.) |
RTC | Supported |
Typical power consumption [W] | Configured with four CE98-D32CQ cards: 1231 W (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 1289 W (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Typical heat dissipation [BTU/hour] | Configured with four CE98-D32CQ cards: 4202 BTU/hour (50% throughput, short-distance QSFP28 optical modules on 64 ports and long-distance QSFP28 optical modules on 64 ports, double power modules) Configured with four CE98-D8DQ cards: 4400 TU/hour (50% throughput, short-distance QSFPDD optical modules on 32 ports, double power modules) |
Static power consumption [W] | Configured with four CE98-D32CQ cards: 377 W Configured with four CE98-D8DQ cards: 548 W |
Static heat dissipation [BTU/hour] | Configured with four CE98-D32CQ cards: 1505 BTU/hour Configured with four CE98-D8DQ cards: 1871 BTU/hour |
Maximum power consumption [W] | Configured with four CE98-D32CQ cards: 1627 W (ambient temperature: 40°C or 104°F; fan speed: 70%) Configured with four CE98-D8DQ cards: 1717 W (ambient temperature: 40°C or 104°F; fan speed: 100%) |
Maximum heat dissipation [BTU/hour] | Configured with four CE98-D32CQ cards: 5553 BTU/hour (ambient temperature: 40°C or 104°F; fan speed: 70%) Configured with four CE98-D8DQ cards: 5861 BTU/hour (ambient temperature: 40°C or 104°F; fan speed: 100%) |
Number of power modules | 4 |
Redundant power supply | 2+2 backup |
Rated input voltage [V] | - Rated input voltage range of 1200 W AC&240 V DC power modules: 100 V AC to 240 V AC; 50/60 Hz, DC: 240 V DC - 1200 W DC power module: -48 V DC: -48 V DC to -60 V DC, +48 V DC: +48 V DC |
Input voltage range [V] | - 1200 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1200 W DC power module: -48 V DC: -38.4 V DC to -72 V DC; +48 V DC: +38.4 V DC to +60 V DC |
Maximum input current [A] | - 1200 W AC&240 V DC power module: 10 A (100 V AC to 130 V AC); 8 A (200 V AC to 240 V AC); 8 A (240 V DC) - 1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC) |
Rated output power [W] | - 1200 W AC&240 V DC power module: 1200 W - 1200 W DC power module: 1200 W |
Maximum output power [W] | 1200 W AC&240 V DC 1200 W -48 V DC |
Certification | - Compliance with safety standards - Compliance with EMC standards - Compliance with environment and environmental protection standards |
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 5 |
Redundant fans | The device supports 4+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side. |
Availability | 0.9999934738 |
MTBF [year] | 21.91 years |
MTTR [hour] | 3.43 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Back-to-front airflow: < 59 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Back-to-front airflow: < 76 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40°C to +70°C (-40°F to +158°F) |
Item | CloudEngine 9860-4C |
Port description | 4 slots, providing up to 128 x 100GE QSFP28 or 32 x 400GE QSFP-DD ports |
Switching capacity | 25.6 Tbit/s |
Packet forwarding rate | 8000 Mpps |
Airflow design | Standard back-to-front airflow |
Device virtualization | M-LAG |
Network convergence | Data Center Bridging Exchange Protocol (DCBX) and PFC |
Remote direct memory access (RDMA) and RoCE (RoCE v1 and RoCE v2) | |
Programmability | OPS programming |
Ansible-based automatic configuration and open-source module release | |
Traffic analysis | NetStream |
sFlow | |
VLAN | Access, trunk, and hybrid |
MAC address table | Automatic MAC address learning and aging |
Static, dynamic, and blackhole MAC address entries | |
Source MAC address filtering | |
MAC address learning limiting based on ports and VLANs | |
IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP |
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
IPv6 | IPv6 neighbor discovery (ND) |
Path MTU Discovery (PMTU) | |
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | |
Multicast | Multicast routing protocols, such as Internet Group Multicast Protocol (IGMP), Protocol |
Independent Multicast-Sparse Mode (PIM-SM), and Protocol Independent Multicast-Dense Mode (PIM-DM) | |
Fast leaving of multicast member interfaces | |
Multicast traffic suppression | |
Reliability | Link Aggregation Control Protocol (LACP) |
STP, RSTP, VBST, and MSTP | |
BPDU protection, root protection, and loop prevention | |
Device Link Detection Protocol (DLDP) | |
VRRP, VRRP load balancing, and BFD for VRRP | |
BFD for BGP, IS-IS, OSPF, and static routes | |
Traffic classification based on Layer 2 headers, Layer 3 headers, and Layer 4 protocol priorities | |
ACL, CAR, re-marking, and scheduling | |
QoS | Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR |
Congestion avoidance mechanisms such as WRED and tail drop | |
Traffic shaping | |
Intelligent O&M | Network-wide path detection |
Telemetry | |
INT (IOAM) enhancement | |
Intelligent lossless network | PFC deadlock prevention |
AI ECN | |
Configuration and maintenance | Terminal access services such as console port login, Telnet, and SSH |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
Hot patches | |
User operation logs | |
ZTP | |
Security and management | Command line authority control based on user levels, preventing unauthorized users from using commands |
Defense against DoS, ARP, and ICMP attacks | |
Port isolation, port security, and sticky MAC | |
Binding of the IP address, MAC address, port number, and VLAN ID | |
Authentication methods, including AAA, RADIUS, and HWTACACS | |
RMON | |
Dimensions (H x W x D) | 175 mm x 442 mm x 765 mm |
Weight (full configuration) | 43.2 kg (including four power modules, four fan modules, and four cards) |
33.04 kg (including four power modules and four fan modules) | |
Environment requirements | Operating temperature: 0°C to 40°C (0 m to 1800 m) |
Storage temperature: -40°C to +70°C | |
Relative humidity: 5% RH to 95% RH (noncondensing) | |
Rated input voltage | Rated input voltage range of a 1200 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC |
1200 W DC power module: -48C DC:-48 V DC to -60 V DC; +48 V DC: +48 V DC | |
Input voltage range | 1200 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC |
1200 W DC power module: -48 V DC: -38.4 V DC to -72 V DC; +48 V DC: +38.4 V DC to +60 V | |
Typical power consumption | Configured with four CE98-D32CQ-A cards: 1291 W (100% traffic load, short-distance 100GE optical modules on 64 ports, normal temperature, fully configured with AC power modules) |
Configured with four CE98-D8DQ cards: 953 W (100% traffic load, short-distance 400GE optical modules on 16 ports, normal temperature, fully configured with AC power modules) | |
Configured with four CE98-D32CQ-F cards: 1313 W (100% traffic load, short-distance 100GE optical modules on 64 ports, normal temperature, fully configured with AC power modules) | |
Configured with four CE98-D8DQ-F cards: 961 W (100% traffic load, short-distance 400GE optical modules on 16 ports, normal temperature, fully configured with AC power modules) | |
Maximum power consumption | Configured with four CE98-D8DQ cards: 1261 W (100% traffic load, short-distance 400GE optical modules on 32 ports, normal temperature, fully configured with AC power modules) |
Configured with four CE98-D32CQ-A cards: 2253 W (100% traffic load, long-distance 100GE optical modules on 128 ports, high temperature, fully configured with AC power modules) | |
Configured with four CE98-D8DQ cards: 1677 W (100% traffic load, long-distance 400GE optical modules on 32 ports, high temperature, fully configured with AC power modules) | |
Configured with four CE98-D32CQ-F cards: 1838 W (100% traffic load, short-distance 100GE optical modules on 128 ports, high temperature, fully configured with AC power modules) | |
Configured with four CE98-D8DQ-F cards: 1321 W (100% traffic load, short-distance 400GE optical modules on 32 ports, high temperature, fully configured with AC power modules) | |
Configured with four CE98-D32CQ-F cards: 2263 W (100% traffic load, long-distance 100GE optical modules on 128 ports, high temperature, fully configured with AC power modules) | |
Configured with four CE98-D8DQ-F cards: 1737 W (100% traffic load, long-distance 400GE optical modules on 32 ports, high temperature, fully configured with AC power modules) |
Software | |
N1-CE98LIC-CFMM | N1-CloudFabric Management SW License for CloudEngine 9800 |
N1-CE98CFMM-SnS1Y | N1-CloudFabric Management SW License for CloudEngine 9800 -SnS-1 Year |
N1-CE98LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 9800 |
N1-CE98CFFD- SnS1Y | N1-CloudFabric Foundation SW License for CloudEngine 9800-SnS-1 Year |
Power | ||
Model | Description | Applicable Product |
PAC2KS12-PB | 1200W AC&240V DC Power Module (Back to Front,Power panel side air-out) |
CE9865-4C |
PDC2K2S12-PB | DC PSU,PDC2K2S12-PB,2200W DC Power Module (Back to Front, Power panel side exhaust) | CE9865-4C |
PHD2KS12-PB | 2000W HVDC power module (back-to-front airflow, panel side exhaust) | CE9865-4C |
Fan box | ||
Model | Description | Applicable Product |
FAN-180C-B | Fan box(B,FAN panel side exhaust) | CE9865-4C |
Subcard | |
CE98-D8DQ-F | CE98:8 Port 400GE QSFP-DD Interface Card |
CE98-D32CQ-F | CE98:32 Port 100GE QSFP28 Interface Card |
![]() |
Packing:1.Original Carton Package. 2. As your requirement. |
![]() |
Delivery:1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software
After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.
![]() |
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu. |
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, Z TE, H 3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours. |
![]() |
![]() |
![]() |
![]() |
![]() |
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.