Description | CE8865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Intake) |
Part Number | 02355RTB |
Model | CE8865-4C |
First supported version | V300R023C10 |
Other part numbers | 02355RTA (CE8865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)) |
02355RTC (CE8865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Exhaust)) | |
02356FKL (CE8865-4C mainframe with license bundle(With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Intake, Software license)) | |
02356FKP (CE8865-4C mainframe with license bundle(With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Exhaust, Software license)) | |
Short Name | CE8865 |
Technical Specifications | |
Dimensions with packaging (H x W x D) [mm (in.)] | 280 mm x 875 mm x 665 mm (11.02 in. x 34.45 in. x 26.18 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | - Basic dimensions (the depth excludes the parts protruding from the body): 88.1 mm x 442.0 mm x 600.0 mm (3.47 in. x 17.40 in. x 23.62 in.) |
- Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 88.1 mm x 442.0 mm x 640.0 mm (3.47 in. x 17.40 in. x 25.20 in.) | |
Weight without packaging [kg (lb)] | 12.76 kg (28.13 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules, cards, and card filler panels) |
15.48 kg (34.13 lb) (with four card filler panels, two power module filler panels, and three fan module filler panels but no power modules, fan modules, and cards) | |
Weight without packaging (full configuration) [kg (lb)] | 16.54 kg (36.46 lb) (with two power modules and three fan modules, but no cards and card filler panels) |
19.26 kg (42.46 lb) (with two power modules, three fan modules, and four card filler panels, but no cards) | |
Weight with packaging [kg (lb)] | 21.3 kg (46.96 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules, cards, and card filler panels) |
24.02 kg (52.96 lb) (with four card filler panels, two power module filler panels, and three fan module filler panels but no power modules, fan modules, and cards) | |
Weight with packaging (full configuration) [kg (lb)] | 25.08 kg (55.29 lb) (with two power modules and three fan modules, but no cards and card filler panels) |
27.8 kg (61.29 lb) (with two power modules, three fan modules, and four card filler panels, but no cards) | |
Chassis height [U] | 2 |
Installation Type | Cabinet installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 16-core, 2 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB x 2 |
SSD Flash | 4GB SSD |
USB | It can be used for log backup and USB-based deployment. |
This function is reserved. | |
Power supply mode | AC,DC,HVDC |
Console port | RJ45 |
Downlink Service interface | For details, see the port description of each card. |
Uplink Service interface | For details, see the port description of each card. |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] | Configured with four CE88-D16CQ-H cards: |
- 650 W (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual AC power modules) | |
- 728 W (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D10CQ-H cards: | |
- 315 W (100% traffic load, copper cables on 20 x 100GE ports, normal temperature, dual AC power modules) | |
- 338 W (100% traffic load, copper cables on 20 x 200GE ports, normal temperature, dual AC power modules) | |
- 345 W (100% traffic load, short-distance optical modules on 20 x 100GE ports, normal temperature, dual AC power modules) | |
- 420 W (100% traffic load, short-distance optical modules on 20 x 200GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D8YS4DQ-H cards: | |
- 306 W (100% traffic load, copper cables on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules) | |
- 406 W (100% traffic load, short-distance optical modules on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D24YS2CQ-H cards: | |
- 305 W (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) | |
- 338 W (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D24T2CQ-H cards: | |
- 381 W (100% traffic load, copper cables on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules) | |
- 388 W (100% traffic load, short-distance optical modules on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules) | |
Typical heat dissipation [BTU/hour] | Configured with four CE88-D16CQ-H cards: |
- 2217.8 BTU/hour (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual AC power modules) | |
- 2483.9 BTU/hour (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D10CQ-H cards: | |
- 1074.8 BTU/hour (100% traffic load, copper cables on 20 x 100GE ports, normal temperature, dual AC power modules) | |
- 1153.3 BTU/hour (100% traffic load, copper cables on 20 x 200GE ports, normal temperature, dual AC power modules) | |
- 1177.1 BTU/hour (100% traffic load, short-distance optical modules on 20 x 100GE ports, normal temperature, dual AC power modules) | |
- 1433 BTU/hour (100% traffic load, short-distance optical modules on 20 x 200GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D8YS4DQ-H cards: | |
- 1044.1 BTU/hour (100% traffic load, copper cables on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules) | |
- 1385.3 BTU/hour (100% traffic load, short-distance optical modules on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D24YS2CQ-H cards: | |
- 1040.7 BTU/hour (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) | |
- 1153.3 BTU/hour (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) | |
Configured with four CE88-D24T2CQ-H cards: | |
- 1300 BTU/hour (100% traffic load, copper cables on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules) | |
- 1323.9 BTU/hour (100% traffic load, short-distance optical modules on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules) | |
Static power consumption [W] | Configured with four CE88-D16CQ-H cards: 569 W |
Configured with four CE88-D10CQ-H cards: 297 W | |
Configured with four CE88-D8YS4DQ-H cards: 297 W | |
Configured with four CE88-D24YS2CQ-H cards: 276 W | |
Configured with four CE88-D24T2CQ-H cards: 330 W | |
Static heat dissipation [BTU/hour] | Configured with four CE88-D16CQ-H cards: 1941.4 BTU/hour |
Configured with four CE88-D10CQ-H cards: 1013.4 BTU/hour | |
Configured with four CE88-D8YS4DQ-H cards: 1013.4 BTU/hour | |
Configured with four CE88-D24YS2CQ-H cards: 941.7 BTU/hour | |
Configured with four CE88-D24T2CQ-H cards: 1126 BTU/hour | |
Maximum power consumption [W] | Configured with four CE88-D16CQ-H cards: |
- 888 W (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal temperature, dual AC power modules) | |
- 1318 W (100% traffic load, long-distance optical modules on 64 x 100GE ports, high temperature, dual AC power modules) | |
- 1376 W (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D10CQ-H cards: | |
- 406 W (100% traffic load, short-distance optical modules on 40 x 100GE ports, normal temperature, dual AC power modules) | |
- 549 W (100% traffic load, short-distance optical modules on 40 x 200GE ports, normal temperature, dual AC power modules) | |
- 612 W (100% traffic load, long-distance optical modules on 40 x 100GE ports, high temperature, dual AC power modules) | |
- 965 W (100% traffic load, long-distance optical modules on 40 x 200GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D8YS4DQ-H cards: | |
- 531 W (100% traffic load, short-distance optical modules on 16 x 400GE + 32 x 25GE ports, normal temperature, dual AC power modules) | |
- 830 W (100% traffic load, long-distance optical modules on 16 x 400GE + 32 x 25GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D24YS2CQ-H cards: | |
- 410 W (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules) | |
- 718 W (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D24T2CQ-H cards: | |
- 455 W (100% traffic load, short-distance optical modules on 96 x 10GE electrical + 8 x 100GE ports, normal temperature, dual AC power modules) | |
- 732 W (100% traffic load, long-distance optical modules on 96 x 10GE electrical + 8 x 100GE ports, high temperature, dual AC power modules) | |
Maximum heat dissipation [BTU/hour] | Configured with four CE88-D16CQ-H cards: |
- 3029.9 BTU/hour (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal temperature, dual AC power modules) | |
- 4497 BTU/hour (100% traffic load, long-distance optical modules on 64 x 100GE ports, high temperature, dual AC power modules) | |
- 4694.9 BTU/hour (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D10CQ-H cards: | |
- 1385.3 BTU/hour (100% traffic load, short-distance optical modules on 40 x 100GE ports, normal temperature, dual AC power modules) | |
- 1873.2 BTU/hour (100% traffic load, short-distance optical modules on 40 x 200GE ports, normal temperature, dual AC power modules) | |
- 2088.1 BTU/hour (100% traffic load, long-distance optical modules on 40 x 100GE ports, high temperature, dual AC power modules) | |
- 3292.6 BTU/hour (100% traffic load, long-distance optical modules on 40 x 200GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D8YS4DQ-H cards: | |
- 1811.8 BTU/hour (100% traffic load, short-distance optical modules on 16 x 400GE + 32 x 25GE ports, normal temperature, dual AC power modules) | |
- 2832 BTU/hour (100% traffic load, long-distance optical modules on 16 x 400GE + 32 x 25GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D24YS2CQ-H cards: | |
- 1398.9 BTU/hour (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules) | |
- 2449.8 BTU/hour (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules) | |
Configured with four CE88-D24T2CQ-H cards: | |
- 1552.5 BTU/hour (100% traffic load, short-distance optical modules on 96 x 10GE electrical ports + 8 x 100GE ports, normal temperature, dual AC power modules) | |
- 2497.6 BTU/hour (100% traffic load, long-distance optical modules on 96 x 10GE electrical ports + 8 x 100GE ports, high temperature, dual AC power modules) | |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | - 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC |
- 1800 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC | |
- 2000 W high-voltage DC power module: 336 V DC | |
- 2200 W DC power module: -48 V DC to -60 V DC; +48 V DC | |
Input voltage range [V] | - 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC |
- 1800 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC | |
- 2000 W high-voltage DC power module: 260 V DC to 400 V DC | |
- 2200 W DC power module: -38.4 V DC to -72 V DC; +38.4 V DC to +57 V DC | |
Maximum input current [A] | - 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) |
- 1800 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) | |
- 2000 W high-voltage DC power module: 10 A (336 V DC) | |
- 2200 W DC power module: 63 A (-48 V DC to -60 V DC); 63 A (+48 V DC) | |
Rated output power [W] | - 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V AC) |
- 1800 W AC&240 V DC power module: 1800 W (200 V AC to 240 V AC&240 V DC), 900 W (100 V AC to 130 V AC) | |
- 2000 W high-voltage DC power module: 2000 W | |
- 2200 W DC power module: 2200 W | |
Certification | - Compliance with safety standards |
- Compliance with EMC standards | |
- Compliance with environment and environmental protection standards | |
Power supply surge protection [kV] | - AC: 6 kV in common mode and 6 kV in differential mode |
- HVDC: 4 kV in common mode and 2 kV in differential mode | |
- DC: 4 kV in common mode and 2 kV in differential mode | |
Types of fans | Pluggable |
Number of fans | 3 |
Redundant fans | The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Availability | 0.9999964621 |
MTBF [year] | 48.4 years |
MTTR [hour] | 1.86 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Port-side air intake: < 64.3 dB(A) |
Port-side air exhaust: < 65.2 dB(A) | |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Port-side air intake: < 86.1 dB(A) |
Port-side air exhaust: < 87.9 dB(A) | |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) |
Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). | |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Packing:
1. Original Carton Package.
2. As your requirement.
Delivery:
1. 3-7 Working days after received the payment.
2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software
After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu.
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, Z TE, H 3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours.
The core team comes from manufacturers such as Hua wei and H3C, with technical staff certified by HCIE, HCNP, and other engineers. Most of them have more than 5 years of work experience and have a 7 * 24 hour fast response ability. They can provide users with planning, debugging, and emergency upgrade services.
The company has its own Data center room and equipment maintenance factory, with a product database of over 300GB, focusing on data communication, transmission, wireless, server, storage, and security products. With no less than 1 year of after-sales tracking, it can provide users with remote and local installation services to ensure the stable.