Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Basic Information | |
Part Number | 02354TDT-002 |
Model | CE6881-48S6CQ-K |
Description | CE6881-48S6CQ-K switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust) |
Technical specifications
Technical Specifications | |
Other part numbers | 02353JAP-002 (CE6881-48S6CQ-K switch (48*10G SFP+, 6*100G QSFP28, without fan and power modules)) 02353JAQ-002 (CE6881-48S6CQ-K switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side intake)) |
Installation Type | Cabinet Installation |
Depth [mm] | 420.0 mm |
Chassis height [U] | 1 |
Wide [mm] | 442.0 mm |
Height [mm] | 43.6 mm |
Weight without packaging [kg(lb)] | 5.7 kg (12.6 lb) (excluding optical modules, power modules, and fan modules) |
Maximum power consumption [W] | 349 W |
Typical power consumption [W] | - 194 W (100% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules) - 240 W (100% throughput, short-distance optical modules on all ports, dual power modules) |
Static power consumption [W] | 161 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation [BTU/hour] | 1191 BTU/hour |
Typical heat dissipation [BTU/hour] | - 662 BTU/hour (100% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules) - 819 BTU/hour (100% throughput, short-distance optical modules on all ports, dual power modules) |
Static heat dissipation [BTU/hour] | 549 BTU/hour |
Power supply mode | AC,DC,HVDC |
Rated input voltage [V] | - 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1000 W DC power module: -48 V DC to -60 V DC - 1200 W high-voltage DC power module: 240 V DC to 380 V DC |
Input voltage range [V] | - 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1000 W DC power module: -38.4 V DC to -72 V DC - 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A] | - 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) - 1000 W DC power module: 30 A (-48 V DC to -60 V DC) - 1200 W high-voltage DC power module: 8 A |
Rated output power [W] | - 600 W AC&240 V DC power module: 600 W - 1000 W DC power module: 1000 W - 1200 W high-voltage DC power module: 1200 W |
Memory | DRAM: 4 GB |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
USB | Supported |
Console port | RJ45 |
Downlink Service interface | 48*10GE SFP+ Note: 1. 10GE ports can be configured to work at 1 Gbit/s. Ports 13-16 and 25-28 can be configured to work at 10 Gbit/s or 1 Gbit/s using commands, and the speed of other ports can be auto-negotiated based on optical modules. (In V200R005C20, ports 13-16 and 25-28 cannot be configured to work at 1 Gbit/s. In V200R019C10 and later versions, they can be configured to work at 1 Gbit/s.) 2. 10GE LRM/80 km linear optical modules are not supported. 3. 10GE 1 m/3 m/5 m copper cables are supported. |
Uplink Service interface | 6*100GE QSFP28 Note: 1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. 2. In V200R022C00 and earlier versions, 100GE ports cannot be split. In V200R022C10, ports 5 and 6 can be split into 4 x 25GE or 4 x 10GE ports. Other ports cannot be split. 40GE/100GE port 5 supports only static split, and 40GE/100GE port 4 is deleted after split is configured. After split is canceled for 40GE/100GE port 5, 40GE/100GE port 5 can be restored, but 40GE/100GE port 4 can be restored only after the card is restarted. After a port is split, the port cannot be connected using a copper cable. When a copper cable is installed on the port, a message is displayed, indicating that the medium does not match. 3. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on stack ports and M-LAG peer-link ports. 100G 3/5 m copper cables support only RS FEC. After the non-RS FEC mode is configured, the port enters the error-down state. |
Service port supporting the stack function | 10GE optical ports and 100GE optical ports |
RTC | Supported |
Switching capacity [bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | 1+1 backup |
Number of power modules | 2 |
Power supply surge protection | - AC: 6 kV in common mode and 6 kV in differential mode - DC: 4 kV in common mode and 2 kV in differential mode - HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Airflow direction | Front-to-back or back-to-front, depending on the fan modules and power modules. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage altitude [m(ft.)] | < 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
MTBF [year] | 45.9 years |
MTTR [hour] | 1.57 hours |
Noise at high temperature (40°C, sound pressure) | - Front-to-back airflow: < 75 dB(A) - Back-to-front airflow: < 74 dB(A) |
Noise at normal temperature (27°C, sound pressure) | - Front-to-back airflow: < 58 dB(A) - Back-to-front airflow: < 57 dB(A) |
Availability | 0.9999960856 |
Product | Feature | N1 Mandatory Software Packages | N1 Add-on Software Packages |
|||
CloudEngine 6881 Series Switch | Management | Foundation | Advanced | Premium | Multi-cloud MultiDC Value-added Package |
|
Basic software | √ | √ | √ | √ | ||
IPV6 | √ | √ | √ | √ | ||
VXLAN | √ | √ | √ | √ | ||
Lossless upgrade | √ | √ | √ | √ | ||
Telemetry | √ | √ | √ | |||
NSH | √ | √ | ||||
iMaster NCE-Fabric | Automatic deployment function | √ | √ | √ | ||
Basic intent functions (simulation and verification, and network-wide configuration rollback) | √ | |||||
Multi-Cloud MultiDC function | √ | |||||
iMaster NCEFabricInsight | Basic network analysis functions of Telemetry | √ | √ | √ |
100 VMs) | ||||||
Version Mapping | Select one from the four options. The Foundation software package contains functions of the Management software package, the Advanced software package contains functions of the Foundation software package, and the Premium software package contains functions of the Advanced software package. | It is used with the Foundation, Advanced, or Premium software package. |
||||
For details about product function differences, refer to the product documentation. |
Item | CloudEngine 6881-48S6CQ | CloudEngine 6881-48T6CQ |
Device virtualization | iStack | |
M-LAG | ||
Network virtualization | VXLAN | |
BGP-EVPN | ||
QinQ access VXLAN | ||
Data center interconnect | VXLAN mapping, implementing interconnection between multiple DCI networks at Layer 2 | |
SDN | iMaster NCE-Fabric | |
Network convergence | PFC and ECN | |
RDMA and RoCE (RoCE v1 and RoCE v2) | ||
Programmability | OPS programming |
Traffic analysis | NetStream |
sFlow | |
VLAN | Adding access, trunk, and hybrid interfaces to VLANs |
Default VLAN | |
QinQ | |
MAC address | Dynamic learning and aging of MAC address entries |
Static, dynamic, and blackhole MAC address entries |
QoS | Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information | |
ACL, CAR, re-marking, and scheduling | ||
Queue scheduling modes such as PQ,DRR and PQ+DRR | ||
Congestion avoidance mechanisms, including WRED and tail drop | ||
Traffic shaping | ||
O&M | iPCA (Packet Conservation Algorithm for Internet) | |
Network-wide path detection | ||
Telemetry | ||
Item | CloudEngine 6881-48S6CQ | CloudEngine 6881-48T6CQ |
ERSPAN+ | ||
Statistics on the buffer microburst status | ||
VXLAN OAM: VXLAN ping and VXLAN tracert | ||
Configuration and maintenance | Console, Telnet, and SSH terminals | |
Network management protocols, such as SNMPv1/v2/v3 | ||
File upload and download through FTP and TFTP BootROM upgrade and remote upgrade |
||
Hot patches | ||
User operation logs | ||
Zero Touch Provisioning (ZTP) |
Mainframe | |
CE6881-48S6CQ | CE6881-48S6CQ switch (48*10G SFP+, 6*100G QSFP28, without fan and power modules) |
CE6881-48S6CQ-B | CE6881-48S6CQ-B switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side intake) |
CE6881-48S6CQ-F | CE6881-48S6CQ-F switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust) |
CE6881-48T6CQ | CE6881-48T6CQ switch (48*10G RJ45, 6*100G QSFP28, without fan and power modules) |
CE6881-48T6CQ-B | CE6881-48T6CQ-B switch(48*10GE RJ45,6*100GE QSFP28,2*AC power modules,4*fan modules,port-side intake) |
CE6881-48T6CQ-F | CE6881-48T6CQ-F switch (48*10G RJ45, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust) |
Model | Description | Applicable Product |
FAN-031A-F | Fan box (F,FAN panel side intake) | CloudEngine 6881 series |
FAN-031A-B | Fan box (B,FAN panel side exhaust) | CloudEngine 6881 series |
Model | Description | Applicable Product |
PAC600S12-CF | 600W AC Power Module(Front to Back,Power panel side intake) |
CloudEngine 6881 series |
PAC600S12-CB | 600W AC Power Module(Back to Front, | CloudEngine 6881 series |
Model | Description | Applicable Product |
Power panel side exhaust) | ||
PDC1000S12-DF | 1000W DC Power Module (Front to Back,Power panel side intake) |
CloudEngine 6881 series |
PDC1000S12-DB | 1000W DC Power Module (Front to Back,Power panel side exhaust) |
CloudEngine 6881 series |
PHD1K2S12-DB | 1200W HVDC Power Module (Back to Front, Power panel side exhaust) |
CloudEngine 6881 series |
Software | |
N1-CE68LIC-CFMM | N1-CloudFabric Management SW License for CloudEngine 6800 |
N1-CE68CFMM-SnS1Y | N1-CE68CFMM-SnS1Y,N1-CloudFabric Management SW License for CloudEngine 6800 |
N1-CE68LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 6800 |
N1-CE68CFFD-SnS1Y | N1-CloudFabric Foundation SW License for CloudEngine 6800-SnS-Year |
N1-CE68LIC-CFAD | N1-CloudFabric Advanced SW License for CloudEngine 6800 |
N1-CE68CFAD-SnS1Y | N1-CloudFabric Advanced SW License for CloudEngine -SnS -Year |
N1-CE68LIC-CFPM | N1-CloudFabric Premium SW License for CloudEngine 6800 |
N1-CE68CFPM-SnS1Y | N1-CloudFabric Premium SW License for CloudEngine 6800 -SnS-Year |
1.Original Carton Package.
2. As your requirement.
1. 3-7 Working days after received the payment.
2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS )
1.Quality: All products from HUA WEI and new.
2.Reply on time: Your inquiry related to our products or price will be replied within 24 hours.
3.OEM&ODM: We can help you to design and put your good idea into products.
4.Warranty: 1-years warranty.
5.Technology support: On-site technical support, Telemaintenance, Free call and E-mail technology supports.
6.Training service support: Provide free training service on installation and debugging technology supports.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu.
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as hw, Z TE, H3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours.
The core team comes from manufacturers such as Hua wei and H3C, with technical staff certified by HCIE, HCNP, and other engineers. Most of them have more than 5 years of work experience and have a 7 * 24 hour fast response ability. They can provide users with planning, debugging, and emergency upgrade services.
The company has its own data transmission room and equipment maintenance factory, with a product database of over 300GB, focusing on data communication, transmission, wireless, server, storage, and security products. With no less than 1 year of after-sales tracking, it can provide users with remote and local installation services to ensure the stable operation of their equipment.
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.