| Customization: | Available |
|---|---|
| Type: | Enterprise Switch |
| Condition: | Original and New |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 98010930 |
Model | CloudEngine S5735S-L32ST4X-A |
Description | S5735S-L32ST4X-A (24*GE SFP ports, 8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power) |




Technical Specifications | |
Chassis material | Metal |
Height[mm] | 43.6 mm |
Depth[mm] | 220.0 mm |
Wide[mm] | 442.0 mm |
Chassis height[U] | 1 |
Weight with packaging[kg(lb)] | 4.31 kg (9.5 lb) |
Maximum power consumption[W] | 65 |
Typical power consumption[W] | 46 |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Maximum heat dissipation[BTU/hour] | 221.8 |
Typical heat dissipation[BTU/hour] | 156.96 |
Power supply mode | AC built-in |
Input voltage range[V] | - AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz - High-Voltage DC input: 190 V DC to 290 V DC |
Rated input voltage[V] | - AC input: 100 V AC to 240 V AC, 50/60 Hz - High-Voltage DC input: 240 V DC |
Maximum input current[A] | 2 A |
Number of power slots | 0 |
Number of card slots | 0 |
Memory | 1 GB |
Flash memory | 512 MB in total. To view the available flash memory size, run the display version command. |
Redundant power supply | Not supported |
Types of fans | Built-in |
Noise at normal temperature (acoustic power)[dB(A)] | 53.3 |
Noise at normal temperature (acoustic pressure)[dB(A)] | 38.5 |
Airflow direction | Air intake from left and front, air exhaustion from right |
Storage temperature[°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Short-term operating temperature[°C(°F)] | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) |
Long-term operating temperature[°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate[°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: - The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year. - The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year. |
Long-term operating relative humidity[RH] | 5% to 95%, noncondensing |
Storage altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
MTBF[year] | 85.87 |
MTTR[hour] | 2 |
Availability | > 0.99999 |
Maximum number of physical ports on the entire device | 36 |
Maximum number of 100GE ports | 0 |
Maximum number of 40GE ports | 0 |
Maximum number of 25GE ports | 0 |
Maximum number of 10GE ports | 4 |
Maximum number of GE ports | 36 |
Maximum number of FE ports | 32 |
10GE optical interface | 4 |
1000M optical interface | 24 |
1000M electrical interface | 8 |
USB | Supported |
Console port | RJ45 |
Eth Management port | RJ45 |
Service port surge protection[kV] | Common mode: ±7 kV |
Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode |