| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 02352KUF |
Model | CE8868-4C-EI |
Description | CE8868-4C-EI Mainframe (With 4 Subcard Slots, Without FAN Box and Power Module) |




Technical Specifications | |
Other part numbers | 02352CHN (CE8868-4C-EI Mainframe(With 4 Subcard Slots,2*AC Power Module,2*FAN Box,Port-side Exhaust)) 02352CHM (CE8868-4C-EI Mainframe(With 4 Subcard Slots, 2*AC Power Module, 2*FAN Box, Port-side Intake)) |
Installation Type | Cabinet Installation |
Depth[mm] | 600 mm |
Chassis height[U] | 2 |
Wide[mm] | 442 mm |
Height[mm] | 88.1 mm |
Weight without packaging[kg(lb)] | 16.8 kg (37.04 lb) (including four cards, without power and fan modules) |
Maximum power consumption[W] | Fully configured with four CE88-D8CQ cards: 658 W Fully configured with four CE88-D16Q cards: 620 W Fully configured with four CE88-D24T2CQ cards: 747 W Fully configured with four CE88-D24S2CQ cards: 674 W Fully configured with four CE88-D24S2CQ-U cards: 795 W Fully configured with four CE88-D24S2CQ1 cards: 986 W |
Typical power consumption[W] | Fully configured with four CE88-D8CQ cards: 398 W (100% throughput, QSFP28 cables on 32 ports, double power modules) Fully configured with four CE88-D16Q cards: 383 W (100% throughput, QSFP+ cables on 64 ports, double power modules) Fully configured with four CE88-D24T2CQ cards: 532 W (100% throughput, 3 m Ethernet cables on 96 ports and QSFP28 cables on 8 ports, double power modules) Fully configured with four CE88-D24S2CQ cards: 437 W (100% throughput, SFP28 cables on 96 ports and QSFP28 cables on 8 ports, double power modules) |
Static power consumption[W] | Configured with four CE88-D24S2CQ cards: 346 W Configured with four CE88-D24T2CQ cards: 329 W Configured with four CE88-D16Q cards: 307 W Configured with four CE88-D8CQ cards: 350 W Configured with four CE88-24S2CQ-U cards: 420 W Configured with four CE88-D24S2CQ1 cards: 433 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation[BTU/hour] | Fully configured with four CE88-D8CQ cards: 2245 BTU/hour Fully configured with four CE88-D16Q cards: 2116 BTU/hour Fully configured with four CE88-D24T2CQ cards: 2549 BTU/hour Fully configured with four CE88-D24S2CQ cards: 2300 BTU/hour Fully configured with four CE88-D24S2CQ-U cards: 2713 BTU/hour Fully configured with four CE88-D24S2CQ1 cards: 3364 BTU/hour |
Typical heat dissipation[BTU/hour] | Fully configured with four CE88-D8CQ cards: 1358 BTU/hour (100% traffic load, QSFP28 cables on 32 ports, dual power modules) Fully configured with four CE88-D16Q cards: 1307 BTU/hour (100% traffic load, QSFP+ cables on 64 ports, dual power modules) Fully configured with four CE88-D24T2CQ cards: 1815 BTU/hour (100% traffic load, 3 m Ethernet cables on 96 ports and QSFP28 cables on 8 ports, dual power modules) Fully configured with four CE88-D24S2CQ cards: 1491 BTU/hour (100% traffic load, SFP28 cables on 96 ports and QSFP28 cables on 8 ports, dual power modules) |
Static heat dissipation[BTU/hour] | Configured with four CE88-D24S2CQ cards: 1181 BTU/hour Configured with four CE88-D24T2CQ cards: 1123 BTU/hour Configured with four CE88-D16Q cards: 1048 BTU/hour Configured with four CE88-D8CQ cards: 1194 BTU/hour Configured with four CE88-24S2CQ-U cards: 1433 BTU/hour Configured with four CE88-D24S2CQ1 cards: 1477 BTU/hour |
Power supply mode | DC pluggable,AC pluggable,HVDC pluggable |
Rated input voltage[V] | AC power input Rated input voltage range: 100 V AC to 130 V AC/200 V AC to 240 V AC, 50/60 Hz DC power input Rated voltage range: –48 V DC to –60 V DC High-voltage DC power input Rated voltage of 240 V high-voltage DC power input: 240 V DC Rated voltage range of 380 V high-voltage DC power input: 240 V DC to 380 V DC |
Input voltage range[V] | AC power input Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz DC power input Maximum voltage range: –38.4 V DC to –72 V DC High-voltage DC power input Maximum voltage range of 240 V high-voltage DC power input: 188 V DC to 290 V DC Rated voltage range of 380 V high-voltage DC power input: 240 V DC to 380 V DC Maximum voltage range of 380 V high-voltage DC power input: 188 V DC to 400 V DC |
Maximum input current[A] | 1200 W AC module: 200 V to 240 V, 8 A; 100 V to 130 V, 10 A (The power consumption can reach 800 W under low voltage.) 1200 W 240 V DC power module: 240 V, 8 A 1200 W 380 V DC power module: 240 V to 380 V, 8 A 1200 W -48 V DC power module: -60 V to -48 V, 38 A |
Rated output power[W] | - 1200 W AC&240 V DC power module: 1200 W - 1200 W DC power module: 1200 W - 1200 W high-voltage DC power module: 1200 W |
Maximum output power[W] | AC&240 V DC: 1200 W -48 V DC: 1200 W 380 V DC: 1200 W |
Memory | DRAM: 4 GB |
NOR Flash | 32MB |
NAND Flash | 2GB |
USB | Supported |
Console port | RJ45 |
Downlink Service interface | For details, see the port description of each card. |
Uplink Service interface | For details, see the port description of each card. |
Service port supporting the stack function | For details, see the port description of each card. |
RTC | Supported |
Switching capacity[bps,bit/s] | For more details, see the datasheet/brochure or contact product sales personnel. |
Redundant fans | Two fan modules, working in 1+1 backup mode when the temperature is below 35°C |
Redundant power supply | 1+1 backup |
Number of power modules | 2 |
Power supply surge protection | AC: 4 kV in common mode and 2.5 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fan modules | 2 |
Airflow direction | Front-to-back or back-to-front airflow, depending on the selected fan modules and power modules |
Storage temperature[°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature[°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Long-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Storage altitude[m(ft.)] | < 5000 m (16404 ft.) |
Long-term operating altitude[m(ft.)] | < 5000 m (16404 ft.) |
MTBF[year] | 36.02 years |
MTTR[hour] | 1.87 hours |
Noise at high temperature (40°C, sound pressure) | Front-to-back airflow: 74 dBA (average); 79 dBA (maximum) Back-to-front airflow: 77 dBA (average); 82 dBA (maximum) |
Noise at normal temperature (27°C, sound pressure) | Back-to-front airflow: < 58 dB(A) Front-to-back airflow: < 56 dB(A) |
Availability | 0.9999940608 |