| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Part Number | 02116318 |
Model | CloudEngine S8700-6 |
Description | S8700-6 assembly chassis |




Technical Specifications[mm] | |
Height[mm] | 352.8 mm |
Depth[mm] | 482.8 mm |
Wide[mm] | 442.0 mm |
Chassis height[U] | 8 |
Weight without packaging[kg(lb)] | 52.7 kg (116.18 lb) (including the device, pallet, auxiliary material package, and cable management frames) |
Maximum power consumption[W] | 1560 W (full configuration, without PoE) |
Heat dissipation mode | Absorbing cold air into the device |
Maximum heat dissipation[BTU/hour] | 5322.94 |
Input voltage range[V] | - DC input: -38.4 V DC to -72 V DC or 38.4 V DC to 57.6 V DC - AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz - High-voltage DC input: 190 V DC to 290 V DC Note: - V600R021C10 and later versions support DC input. - In V600R021C10 and later versions, the 3000 W output capability of AC power modules (2500 W/3000 W AC&240 V DC power modules) can be enabled using a command. |
Rated input voltage[V] | - DC input: –48 V DC/–60 V DC/48 V DC - AC input: 110 V AC/220 V AC, 50/60 Hz - High-voltage DC input: 240 V DC Note: V600R021C10 and later versions support DC power input. |
Number of MPU slots | 2 |
Number of service board slots | 4 Note: The main control board can provide service ports, which have the same service access capability as those on the service board. |
Number of power slots | 6 |
Redundant fans | Fan modules work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | - Dual-power input: The N+0 and N+1 modes are supported. The N+1 mode is recommended. - Single-power input: The N+0, N+1, and N+N modes are supported. The N+1 mode is recommended. |
Redundant MPUs | The control unit and switching unit work in hot standby (1:1) mode. |
Automatic fan speed adjustment | Supported |
Noise at normal temperature (acoustic power)[dB(A)] | - ≤ 78.0 dB(A) @ 1500 W AC - ≤ 78.0 dB(A) @ 2500 W AC - ≤ 73.8 dB(A) @ 2200 W DC N+1 power supply. In N+0 power supply mode, it is recommended that the DC power output be within 1780 W. Otherwise, the noise may exceed 78 dB(A). Note: - In V600R021C10 and later versions, 2200 W DC power modules are supported. - In V600R021C10 and later versions, N+N AC power modules can be configured. - In V600R021C10 and later versions, the 3000 W capability of the AC power module (2500 W/3000 W AC&240 V DC power module) can be enabled using a command. |
Airflow direction | Front-to-back airflow |
Storage temperature[°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Short-term operating temperature[°C(°F)] | –5°C to +55°C (23°F to 131°F) at an altitude of –60 m to 1800 m (–197 ft. to 5906 ft.) Note: When the short-term operating temperature ranges from 45°C to 55°C (113°F to 131°F): - If the PAC3KS54-DF (2500 W/3000 W AC&240 V DC power module) is used for power supply, the short-term operating temperature can reach 55°C only when the system is configured to work in N+1 power supply mode (the output power of a single power module is less than 2100 W). - Only optical modules with a transmission distance less than or equal to 10 km can be used. |
Long-term operating temperature[°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of –60 m to +1800 m (–197 ft. to +5906 ft.) |
Restriction on the operating temperature variation rate[°C(°F)] | When the altitude is 1800 m to 5000 m (5905.44 ft. to 16404.00 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Long-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
Storage altitude[m(ft.)] | < 5000 m (16404 ft.) |
Long-term operating altitude[m(ft.)] | –60 m to +5000 m (–197 ft. to 16404 ft.) |
MTBF[year] | 32.04 |
MTTR[hour] | 2 |
Availability | 0.9999928743 |
Maximum number of 100GE ports | - Versions earlier than V600R023C10: 2 x 100GE - V600R023C10: 22 x 100GE - V600R024C00 and later versions: 70 x 100GE |
Maximum number of 40GE ports | - Versions earlier than V600R023C00: 4 x 40GE - V600R023C00: 20 x 40GE - V600R023C10: 22 x 40GE - V600R024C00 and later versions: 134 x 40GE |
Maximum number of 25GE ports | - Versions earlier than V600R022C00: 8 x 25GE - V600R022C00 to V600R023C00: 72 x 25GE - V600R023C10 to V600R024C00: 80 x 25GE - V600R024C10 and later versions: 208 x 25GE |
Maximum number of 10GE ports | - Versions earlier than V600R023C10: 208 x 10GE - V600R023C10 and later versions: 312 x 10GE - V600R025C00 and later versions: 312 x 10GE (fully configured with PEN cards: 536 x 10GE) |
Maximum number of GE ports | - Versions earlier than V600R023C10: 208 x GE - V600R023C10 and later versions: 312 x GE |
Power supply surge protection | - 2500 W/3000 W and 1500 W AC&240 V DC power module, AC input mode, power port: ±6 kV in common mode and ±6 kV in differential mode; HVDC input mode, power port: ±2 kV in common mode and ±4 kV in differential mode - 2200 W DC power module, DC power port: ±2 kV in common mode, ±6 kV in differential mode Note: - In V600R021C10 and later versions, 2200 W DC power modules are supported. - In V600R023C10 and later versions, 1500 W AC&240 V DC power modules are supported. |
PoE | Supported |
Relationship between PoE and system power modules | Shared, not differentiated |
Maximum PoE output power per slot | 4800 W (2880 W/slot for the current card) |
Maximum number of PoE ports per slot | 48 |
Maximum PoE output power[W] | 90 |