Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Part Number | 98011995 | |
Model | S5735-L16T4S-A-V2 | |
Description | S5735-L16T4S-A-V2 (16*10/100/1000BASE-T ports, 4*GE SFP ports, AC power) |
hardware Specifications
Height [mm] | 43.6 mm |
Depth [mm] | 220.0 mm |
Wide [mm] | 442.0 mm |
Chassis height [U] | 1 |
Weight with packaging [kg(lb)] | 3.34 (7.36) |
Weight without packaging [kg(lb)] | 2.22 (4.89) |
Maximum power consumption [W] | 28.84 |
Typical power consumption [W] | 21.17 |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Maximum heat dissipation [BTU/hour] | 98.4 |
Typical heat dissipation [BTU/hour] | 72.23 |
Power supply mode | AC built-in |
Input voltage range [V] | AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz |
Rated input voltage [V] | AC input: 100-240 V AC; 50/60 Hz |
Maximum input current [A] | 0.8 A |
Number of power slots | 0 |
Number of card slots | 0 |
Memory | 2 GB |
Flash memory | Physical space: 1 GB |
Redundant power supply | Not supported |
Types of fans | Built-in |
Noise at normal temperature (acoustic power) [dB(A)] | 47 |
Noise at normal temperature (acoustic pressure) [dB(A)] | 35 |
Airflow direction | Air intake from left and front, air exhaustion from right |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
MTBF [year] | 72.43 |
MTTR [hour] | 2 |
Availability | > 0.99999 |
Maximum number of physical ports on the entire device | 20 |
Maximum number of 100GE ports | 0 |
Maximum number of 40GE ports | 0 |
Maximum number of 25GE ports | 0 |
Maximum number of 10GE ports | 0 |
Maximum number of GE ports | 20 |
Maximum number of FE ports | 16 |
1000M optical interface | 4 |
1000M electrical interface | 16 |
USB | Not supported |
Console port | RJ45 |
Eth Management port | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection | Differential mode: ±6 kV; common mode: ±6 kV |
RPS input | Not supported |
PoE | Not supported |
Item | CloudEngine S5735-L16T4SAV2 | |
Physical specification | Dimensions (H x Wx D) | 43.6 mm x 442 mm x 220 mm |
Chassis height | 1 U | |
Chassis weight (including packaging) | 5.59kg | |
Fixed port | GE port | 16 |
GE SFP pot | 4 | |
10GE port | NA | |
Management port | Console port | Supported |
(RJ45) | ||
USB Port | NA | |
CPU | Frequency | 1.1 GHz |
Core | 2 | |
Storage | Memory (RAM) | 2 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display | |
Power supply system | Power supply type | Built-in AC |
Rated voltage range | 100 V AC to 240 V | |
AC, 50/60 Hz | ||
Maximum voltage range | « AC input: 90 V AC to 290 V AC, 45 | |
Hz to 65 Hz | ||
Maximum input | 0.8A | |
current | ||
Maximum power consumption of the | 30.4W | |
device | ||
Typical power consumption | 20.4 W | |
Power consumption in | 21.4 W | |
the case of 100% traffic | ||
load1 | ||
Heat dissipation system | Heat dissipation mode | Air-cooled heat dissipation and intelligent speed adjustment |
Number of fan modules | 1 | |
Airflow | Air intake from left and front, air exhaustion from right | |
Maximum heat | 103.73 | |
dissipation of the device (BTU/hour) | ||
Environment parameters | Long-term operating temperature | « 0-1800 m altitude: |
-5°C to +50°C | ||
« 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. | ||
Short-term operating temperature3 | NA | |
Storage temperature | -40°C to +70°C | |
Relative humidity | 5%- | |
95%(noncondensing) | ||
Operating | 5000 m | |
altitude | ||
Noise under normal temperature (sound power) | 47 dB(A) | |
Noise under high temperature | 51 dB(A) | |
(sound power) | ||
Noise under normal temperature (sound pressure) | 35 dB(A) | |
Surge protection specification | ±7 kV in common mode | |
(RJ45 service | ||
port) | ||
Surge protection specification (power port) | « Differential mode: | |
± 6 kV | ||
« Common mode: ± | ||
6 kV | ||
Reliability | MTBF (year)2 | 72.43 |
MTTR (hour) | 2 | |
Availability | > 0.99999 | |
Certification | EMC certification | |
Safety certification | ||
Manufacturing certification |
BOM Number
|
License Control Item
|
Abbreviation
|
Description
|
---|---|---|---|
88035YSP |
N1-CloudCampus,Advanced,S57XX-L Series,Per Device |
N1-S57L-A-Lic |
The advanced package contains the following function items: |
88062HBL |
N1-Upgrade-Foundation to Advanced,S57XX-L,SnS,Per Device,3 Year |
N1-S57L-FToA-SnS-3Y |
CampusInsight-Network Intelligent Analysis, Foundation, X7 Series Fixed Switch, SnS, Per Device, 3 Year |
88062GJU |
N1-CloudCampus,Foundation,S57XX-L Series,SnS,Per Device,10 Year |
N1-S57L-F-SnS-10Y |
S57XX-L Series Basic SW,SnS,Per Device,10 Year |
88063PVM |
N1-CloudCampus, Add-On Package, Endpoints Plug and Play, Software Subscription and Support, Per 30 Endpoints,7 Years |
N1-EPNP-30-SnS-7Y |
Management License,Endpoint Plug And Play,Subscription And Support, Per 30 Terminals,7 Year |
88063YTB |
N1-Upgrade-Foundation to Advanced,S57XX-L,SnS,Per Device,8 Year |
N1-S57L-FToA-SnS-8Y |
CampusInsight,CI-X7FSwitch-F-SnS8Y,CampusInsight-Network Intelligent Analysis, Foundation, X7 Series Fixed Switch, SnS, Per Device, 8 Year |
88063YGV |
N1-CloudCampus, Add-On Package, Intelligent Application Analysis, X7 Series Fixed Switch, Software Subscription and Support, Per Device,2 Year |
N1-APP-X7FSwitch-SnS-2Y |
CampusInsight,CI-X7FSwitch-A-SnS2Y,CampusInsight-Network Intelligent Analysis Application Analysis,Premium,X7 Series Fixed Switch,SnS,Per Device,2 Year |
88062YHY |
N1-Upgrade-Basic Software to Foundation,S57XX-L,SnS,Per Device,5 Year |
N1-S57L-MToF-SnS-5Y |
Management License,Access Management,Subscription And Support, Per 30 Terminals,5 Year |
88063YST |
N1-CloudCampus,Advanced,S57XX-L Series,SnS,Per Device,2 Year |
N1-S57L-A-SnS-2Y |
CampusInsight,CI-X7FSwitch-F-SnS2Y,CampusInsight-Network Intelligent Analysis, Foundation, X7 Series Fixed Switch, SnS, Per Device, 2 Year |
88036KSH |
N1-CloudCampus, Add-On Package, Intelligent Application Analysis, X7 Series Fixed Switch, Per Device |
N1-APP-X7FSwitch |
CampusInsight-Network Intelligent Analysis Application Analysis,Premium,X7 Series Fixed Switch,Per Device |
88062GME |
N1-CloudCampus, Add-On Package, Access Management, Software Subscription and Support, Per 30 Endpoints,5 Year |
N1-AM-30-SnS-5Y |
Management License,Access Management,Subscription And Support, Per 30 Terminals,5 Year |
88062GLX |
S57XX-L Series Basic SW,SnS,Per Device,5 Year |
N1-S57L-M-SnS-5Y |
- |
88063YSY |
N1-Upgrade-Foundation to Advanced,S57XX-L,SnS,Per Device,4 Year |
N1-S57L-FToA-SnS-4Y |
CampusInsight,CI-X7FSwitch-F-SnS4Y,CampusInsight-Network Intelligent Analysis, Foundation, X7 Series Fixed Switch, SnS, Per Device, 4 Year |
88062GMQ |
N1-CloudCampus, Add-On Package, Intelligent Application Analysis, X7 Series Fixed Switch, Software Subscription and Support, Per Device,10 Year |
N1-APP-X7FSwitch-SnS-10Y |
CampusInsight-Network Intelligent Analysis Application Analysis,Premium,X7 Series Fixed Switch,SnS,Per Device,10 Year |
88063YSR |
N1-Upgrade-Basic Software to Foundation,S57XX-L,SnS,Per Device,6 Year |
N1-S57L-MToF-SnS-6Y |
Management License,Access Management,Subscription And Support, Per 30 Terminals,6 Year |
88063YSP |
N1-Upgrade-Basic Software to Foundation,S57XX-L,SnS,Per Device,2 Year |
N1-S57L-MToF-SnS-2Y |
Management License,Access Management,Subscription And Support, Per 30 Terminals,2 Year |
88035YSN |
N1-Upgrade-Foundation to Advanced,S57XX-L,Per Device |
N1-S57L-FToA-Lic |
In addition to the functions delivered by the foundation package, the advanced package supports the following function items: |
88060TQW |
N1-CloudCampus,Foundation,S57XX-L Series,SnS,Per Device,1 Year |
N1-S57L-F-SnS-1Y |
S57XX-L Series Basic SW,SnS,Per Device,1 Year |
88062YHX |
N1-Upgrade-Basic Software to Foundation,S57XX-L,SnS,Per Device,3 Year |
N1-S57L-MToF-SnS-3Y |
Management License,Access Management,Subscription And Support, Per 30 Terminals,3 Year |
88062YJA |
N1-Upgrade-Basic Software to Foundation,S57XX-L,SnS,Per Device,10 Year |
N1-S57L-MToF-SnS-10Y |
Management License,Access Management,Subscription And Support, Per 30 Terminals,10 Year |
88063YSW |
N1-CloudCampus,Advanced,S57XX-L Series,SnS,Per Device,8 Year |
N1-S57L-A-SnS-8Y |
CampusInsight,CI-X7FSwitch-F-SnS8Y,CampusInsight-Network Intelligent Analysis, Foundation, X7 Series Fixed Switch, SnS, Per Device, 8 Year |
Model | Product Description |
CloudEngine S5735-L8T4SA-V2 | CloudEngine S5735-L8T4S-A-V2 (8*10/100/1000BASE-T ports, 4*GE SFP ports, AC power) |
CloudEngine S5735-L8P4SA-V2 | CloudEngine S5735-L8P4S-A-V2 (8*10/100/1000BASE-T ports, 4*GE SFP ports, PoE+, AC power) |
CloudEngine S5735-L8T4XQA-V2 | CloudEngine S5735-L8T4X-QA-V2(8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power, Fanless) |
CloudEngine S5735-L8P4XQA-V2 | CloudEngine S5735-L8P4X-QA-V2(8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, PoE+, AC power, Fanless) |
CloudEngine S5735L10T4X-A-V2 | CloudEngine S5735-L10T4X-TA-V2 (10*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power) |
CloudEngine S5735L10T4X-TA-V2 | CloudEngine S5735-L10T4X-TA-V2 (10*10/100/1000BASE-T ports, 4*10GE SFP+ ports, HTM, AC power) |
CloudEngine S5735L8P2T4X-A-V2 | CloudEngine S5735-L8P2T4X-TA-V2 (8*10/100/1000BASE-T ports(PoE+),2*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power) |
CloudEngine S5735L8P2T4X-TA-V2 | CloudEngine S5735-L8P2T4X-TA-V2 (8*10/100/1000BASE-T ports(PoE+),2*10/100/1000BASE-T ports, 4*10GE SFP+ ports, HTM, AC power) |
CloudEngine S5735L16T4S-A-V2 | CloudEngine S5735-L16T4S-A-V2 (16*10/100/1000BASE-T ports, 4*GE SFP ports, AC power) |
CloudEngine S5735L16T4X-QA-V2 | CloudEngine S5735-L16T4X-QA-V2 (16*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power, Fanless) |
CloudEngine S5735L24T4S-A-V2 | CloudEngine S5735-L24T4S-A-V2 (24*10/100/1000BASE-T ports, 4*GE SFP ports, AC power) |
CloudEngine S5735L24P4S-A-V2 | CloudEngine S5735-L24P4S-A-V2 (24*10/100/1000BASE-T ports, 4*GE SFP ports, PoE+, AC power) |
CloudEngine S5735L24T4X-QA-V2 | CloudEngine S5735-L24T4X-QA-V2 (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power, Fanless) |
CloudEngine S5735L24T4XE-A-V2 | CloudEngine S5735-L24T4XE-A-V2 (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, AC power) |
CloudEngine S5735L24T4XE-D-V2 | CloudEngine S5735-L24T4XE-D-V2 (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, DC power) |
CloudEngine S5735L24P4XE-A-V2 | CloudEngine S5735-L24P4XE-TA-V2 (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, AC power) |
CloudEngine S5735L24P4XE-TA-V2 | CloudEngine S5735-L24P4XE-TA-V2 (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, HTM, AC power) |
CloudEngine S5735L48T4S-A-V2 | CloudEngine S5735-L48T4S-A-V2 (48*10/100/1000BASE-T ports, 4*GE SFP ports, AC power) |
CloudEngine S5735-L48LP4S-A-V2 | CloudEngine S5735-L48LP4S-A-V2 (48*10/100/1000BASE-T ports, 4*GE SFP ports, PoE+, AC power) |
CloudEngine S5735L48P4XE-A-V2 | CloudEngine S5735-L48P4XE-A-V2 (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, 1*AC power) |
CloudEngine S5735L48T4XE-TA-V2 | CloudEngine S5735-L48T4XE-TA-V2 (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, HTM, AC power) |
CloudEngine S5735L48T4XE-D-V2 | CloudEngine S5735-L48T4XE-D-V2 (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, PoE+, DC power) |
CloudEngine S5735L48P4XE-A-V2 | CloudEngine S5735-L48P4XE-A-V2 (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, AC power) |
CloudEngine S5735L48LP4XE-A-V2 | CloudEngine S5735-L48LP4XE-A-V2 (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*stack ports, PoE+, 1*AC power) |
PAC1000S56-EB | 1000W AC PoE power module, can be used in CloudEngine S5735-L48P4XE-A-V2 |
PAC1000S56-DB | 1000W AC PoE power module,can be used in CloudEngine S5735-L48P4X-A |
N1-S57L-M-Lic | S57XX-L Series Basic SW,Per Device |
N1-S57L-M-SnS1Y | S57XX-L Series Basic SW,SnS,Per Device,1Year |
N1-S57L-F-Lic | N1-CloudCampus,Foundation,S57XX-L Series,Per Device |
N1-S57L-F-SnS | N1-CloudCampus,Foundation,S57XX-L Series,SnS,Per Device |
N1-S57L-A-Lic | N1-CloudCampus,Advanced,S57XX-L Series,Per Device |
N1-S57L-A-SnS | N1-CloudCampus,Advanced,S57XX-L Series,SnS,Per Device |
N1-S57L-FToA-Lic | N1-Upgrade-Foundation to Advanced,S57XX-L,Per Device |
N1-S57L-FToA-SnS | N1-Upgrade-Foundation to Advanced,S57XX-L,SnS,Per Device |
Packing:1.Original Carton Package. 2. As your requirement. |
|
Delivery:1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) |
Installation Instructions:
1. Original equipment installation documents can be provided, and installation videos can be provided for some products;
2. Technicians provide remote video guidance for installation;
3. Provide software upgrade documentation and partial upgrade software
After Sales Service:
1. Quality: All products are assumed to be brand new and traceable in origin.
2. Timely response: Your inquiries about our products or prices will be replied to within 4 hours.
3. OEM&ODM: We support helping you design and transform your good ideas into products.
4. Warranty: The default warranty is 1 year, which can be extended according to customer needs. The software provides upgrade and expansion services.
5. Technical support: on-site technical support, remote maintenance, free phone and email technical support.
6. Training service support: Free installation, debugging, technical support, and training services are provided.
Kuanlu Information Technology Co., Ltd.(Kuanlu LTD) is a secondary operator in China, with 10 years of experience in data center operations. It provides services to over 200 data centers and secondary operators, and its end customers include many well-known internet companies such as Tencent and Wangsu. |
Kuanlu is also a domestic telecommunications equipment and service provider, and a gold medal agent for multiple devices such as HW, Z TE, H 3C, and Ruijie. It can deliver carrier level network hardware products at lower prices, and core network equipment inventory exceeding $5 million can deliver products within 72 hours. |
1.How can i get the price?
We usually quote within 24 hours after we get your inquiry (Except weekend and holidays). If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
Yes. Please feel free to contact us.
3.What is your lead time?
It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.
4.What is yourpayment term?
-T/T, Western Union, Money Gram, and Paypal. This is negotiable.
5.What is the shipping method?
It could be shipped by sea, by air or by express (EMS,UPS,DHL,TNT,FEDEX and ect). Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
a. We keep good quality and competitive price to ensure our customers benefit;
b. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.